Demo Data from EDBT 2026 / reviewers in the wild / expert
Toshikatsu Washio
dblp:00/5961
· DBLP profile ↗
6ranked-venue papers
1as first author
0since 2021 · last 2006
0000-0003-2006-8371ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Graphics, computer vision, multimedia, augmented reality and games · 4 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 4 · 1 first-authorArtificial intelligence and machine learning · 2Systems, architecture and hardware · 2
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
2 papers |
Medical and health informatics · 100% | |
| Artificial intelligence
1 paper |
Robot manipulation · 100% | |
| Computer architecture, parallel and distributed computing, and storage systems
1 paper |
Integrated circuit design · 100% |
Topics — the 4 heaviest of 6, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics › medical robotics
MRI-compatible robot |
0.1 | 1 | 2006 | Numerical Simulations and Lab Tests for Design of MR-compatible Robots · ICRA 2006 |
Medical and health informatics
surgical robotics |
0.1 | 1 | 2006 | Numerical Simulations and Lab Tests for Design of MR-compatible Robots · ICRA 2006 |
Robotics › Robot manipulation
force sensing |
0.0 | 1 | 2003 | Robotic needle insertion: effects of friction and needle geometry · ICRA 2003 |
Integrated circuit design
electromagnetic compatibility |
0.0 | 1 | 2006 | Numerical Simulations and Lab Tests for Design of MR-compatible Robots · ICRA 2006 |
Methods — techniques the papers use, named apart from their topics
spectrum analysis · 0.1magnetic field simulation · 0.1finite element method · 0.1CT fluoroscopic imaging · 0.1
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2006 | Numerical Simulations and Lab Tests for Design of MR-compatible RobotsabstractA numerical simulation of the magnetic field in the imaging volume of a magnetic resonance imaging (MRI) scanner and a method for quick searches for electromagnetic noise source are proposed as part of the design and development process for surgical robots that are compatible with MRI. Although MR compatibility is a major challenge for development of such robots, no simulation method was known that could predict it. This paper demonstrates the potential of two basic techniques that are useful in predicting the magnetic and electromagnetic compatibility. First, the distortion of the magnetic field caused by the robot can be computed by a finite element method. Simulation of the resonance signal distribution showed good agreement with experimentally obtained signal distributions. Second, a noise source and its strength can be visualized by a spectrum analyzer Kiyoyuki Chinzei, Kiyoshi Yoshinaka, Toshikatsu Washio |
ICRA | 3 |
| 2004 | Needle Force Sensor, Robust and Sensitive Detection of the Instant of Needle Puncture
Toshikatsu Washio, Kiyoyuki Chinzei |
MICCAI (2) | 1 |
| 2003 | Robotic needle insertion: effects of friction and needle geometryabstractTwo experiments were performed to determine the effects of friction and needle geometry during robotic needle insertion into soft tissues. In Experiment I, friction forces along the instrument axis were characterized during needle insertion into bovine liver under CT fluoroscopic imaging. Because the relative velocity of the tissue and needle affect viscous and Coulomb friction, the needle insertion process was segmented into several phases of relative motion: none, partial and complete. During the complete relative motion phase, it was found that Coulomb friction accounts for the majority of needle force. In Experiment II, insertion forces along and orthogonal to the needle axis were measured during insertion into a silicone rubber phantom with a consistency similar to liver. The effects of needle diameter and tip type (bevel, cone, and triangle) on insertion force were characterized. A bevel tip causes more needle bending and is more easily affected by tissue density variations. Forces for larger diameter needles are higher due to increased cutting and friction forces. These results may be used in the control of needle insertion for robot-assisted percutaneous therapies. Mark D. O'Leary, Christina Simone, Toshikatsu Washio, Kiyoshi Yoshinaka, Allison M. Okamura |
ICRA | 3 |
| 2002 | Measurement of the Tip and Friction Force Acting on a Needle during Penetration
Hiroyuki Kataoka, Toshikatsu Washio, Kiyoyuki Chinzei, Kazuyuki Mizuhara, Christina Simone, Allison M. Okamura |
MICCAI (1) | 2 |
| 2002 | Endoscope Manipulator for Trans-nasal Neurosurgery, Optimized for and Compatible to Vertical Field Open MRI
Yoshihiko Koseki, Toshikatsu Washio, Kiyoyuki Chinzei, Hiroshi Iseki |
MICCAI (1) | 2 |
| 2001 | A Model for Relations between Needle Deflection, Force, and Thickness on Needle Penetration
Hiroyuki Kataoka, Toshikatsu Washio, Michel A. Audette, Kazuyuki Mizuhara |
MICCAI | 2 |