Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Toshikatsu Washio

dblp:00/5961 · DBLP profile ↗
← Back
6ranked-venue papers
1as first author
0since 2021 · last 2006
0000-0003-2006-8371ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Graphics, computer vision, multimedia, augmented reality and games · 4 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 4 · 1 first-authorArtificial intelligence and machine learning · 2Systems, architecture and hardware · 2

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%
Artificial intelligence
1 paper
Robot manipulation · 100%
Computer architecture, parallel and distributed computing, and storage systems
1 paper
Integrated circuit design · 100%

Topics — the 4 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › medical robotics
MRI-compatible robot
0.112006
Numerical Simulations and Lab Tests for Design of MR-compatible Robots · ICRA 2006
Medical and health informatics
surgical robotics
0.112006
Numerical Simulations and Lab Tests for Design of MR-compatible Robots · ICRA 2006
Robotics › Robot manipulation
force sensing
0.012003
Robotic needle insertion: effects of friction and needle geometry · ICRA 2003
Integrated circuit design
electromagnetic compatibility
0.012006
Numerical Simulations and Lab Tests for Design of MR-compatible Robots · ICRA 2006

Methods — techniques the papers use, named apart from their topics

spectrum analysis · 0.1magnetic field simulation · 0.1finite element method · 0.1CT fluoroscopic imaging · 0.1
YearPublicationVenuePosition
2006 Numerical Simulations and Lab Tests for Design of MR-compatible Robots
abstract
A numerical simulation of the magnetic field in the imaging volume of a magnetic resonance imaging (MRI) scanner and a method for quick searches for electromagnetic noise source are proposed as part of the design and development process for surgical robots that are compatible with MRI. Although MR compatibility is a major challenge for development of such robots, no simulation method was known that could predict it. This paper demonstrates the potential of two basic techniques that are useful in predicting the magnetic and electromagnetic compatibility. First, the distortion of the magnetic field caused by the robot can be computed by a finite element method. Simulation of the resonance signal distribution showed good agreement with experimentally obtained signal distributions. Second, a noise source and its strength can be visualized by a spectrum analyzer
Kiyoyuki Chinzei, Kiyoshi Yoshinaka, Toshikatsu Washio
ICRA3
2004 Needle Force Sensor, Robust and Sensitive Detection of the Instant of Needle Puncture
Toshikatsu Washio, Kiyoyuki Chinzei
MICCAI (2)1
2003 Robotic needle insertion: effects of friction and needle geometry
abstract
Two experiments were performed to determine the effects of friction and needle geometry during robotic needle insertion into soft tissues. In Experiment I, friction forces along the instrument axis were characterized during needle insertion into bovine liver under CT fluoroscopic imaging. Because the relative velocity of the tissue and needle affect viscous and Coulomb friction, the needle insertion process was segmented into several phases of relative motion: none, partial and complete. During the complete relative motion phase, it was found that Coulomb friction accounts for the majority of needle force. In Experiment II, insertion forces along and orthogonal to the needle axis were measured during insertion into a silicone rubber phantom with a consistency similar to liver. The effects of needle diameter and tip type (bevel, cone, and triangle) on insertion force were characterized. A bevel tip causes more needle bending and is more easily affected by tissue density variations. Forces for larger diameter needles are higher due to increased cutting and friction forces. These results may be used in the control of needle insertion for robot-assisted percutaneous therapies.
Mark D. O'Leary, Christina Simone, Toshikatsu Washio, Kiyoshi Yoshinaka, Allison M. Okamura
ICRA3
2002 Measurement of the Tip and Friction Force Acting on a Needle during Penetration
Hiroyuki Kataoka, Toshikatsu Washio, Kiyoyuki Chinzei, Kazuyuki Mizuhara, Christina Simone, Allison M. Okamura
MICCAI (1)2
2002 Endoscope Manipulator for Trans-nasal Neurosurgery, Optimized for and Compatible to Vertical Field Open MRI
Yoshihiko Koseki, Toshikatsu Washio, Kiyoyuki Chinzei, Hiroshi Iseki
MICCAI (1)2
2001 A Model for Relations between Needle Deflection, Force, and Thickness on Needle Penetration
Hiroyuki Kataoka, Toshikatsu Washio, Michel A. Audette, Kazuyuki Mizuhara
MICCAI2