Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Kiyoyuki Chinzei

dblp:02/2347 · DBLP profile ↗
← Back
12ranked-venue papers
4as first author
0since 2021 · last 2011
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Graphics, computer vision, multimedia, augmented reality and games · 8 · 2 first-authorApplied, interdisciplinary, general and emerging computing · 8 · 2 first-authorArtificial intelligence and machine learning · 4 · 2 first-authorSystems, architecture and hardware · 4 · 2 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%
Artificial intelligence
1 paper
Motion planning and robot control · 100%
Computer architecture, parallel and distributed computing, and storage systems
1 paper
Integrated circuit design · 100%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › medical robotics
MRI-compatible robot
0.122006
Numerical Simulations and Lab Tests for Design of MR-compatible Robots · ICRA 2006
Remote actuation mechanism for mr-compatible manipulator using leverage and parallelogram - workspace analysis, workspace control, and stiffness evaluation · ICRA 2003
Medical and health informatics
surgical robotics
0.112006
Numerical Simulations and Lab Tests for Design of MR-compatible Robots · ICRA 2006
Robotics › Motion planning and robot control
robot control
0.012003
Remote actuation mechanism for mr-compatible manipulator using leverage and parallelogram - workspace analysis, workspace control, and stiffness evaluation · ICRA 2003
Integrated circuit design
electromagnetic compatibility
0.012006
Numerical Simulations and Lab Tests for Design of MR-compatible Robots · ICRA 2006

Methods — techniques the papers use, named apart from their topics

spectrum analysis · 0.1magnetic field simulation · 0.1finite element method · 0.1workspace analysis · 0.1stiffness evaluation · 0.1parallelogram mechanism · 0.1leverage mechanism · 0.1
YearPublicationVenuePosition
2011 Coaxial needle insertion assistant for epidural puncture
abstract
Detection of internal puncture during manual needle insertion is challenging due to the large friction force between a needle shaft and surrounding tissue, which masks small changes in force at the needle tip. A novel robotic coaxial needle insertion assistant was developed to enhance operator perception during epidural puncture. The coaxial needle separates the cutting force at the needle tip from shear friction on the needle shaft. When the assistant is inactive, the human operator controls the motion of the coaxial needle. When the assistant is active under position control, a motor controls the motion of the outer needle, while the operator controls only the motion of the inner needle. When the assistant is active under force control, the operator controls the motion of the entire needle, but receives force feedback that is a scaled version of the force applied by the needle tip to the tissue. The effectiveness of the assistant in enabling puncture detection was tested in an experiment in which users were asked to puncture artificial tissues with the assistant inactive and active. Results show that the ratio of successful to unsuccessful puncture detection was higher with the assistant than without. In addition, users were more confident that they could perceive the moment of puncture. However, when the users successfully perceived puncture, overshoot with the assistant was larger than without.
Yoshihiko Koseki, Danilo De Lorenzo, Kiyoyuki Chinzei, Allison M. Okamura
IROS3
2006 Numerical Simulations and Lab Tests for Design of MR-compatible Robots
abstract
A numerical simulation of the magnetic field in the imaging volume of a magnetic resonance imaging (MRI) scanner and a method for quick searches for electromagnetic noise source are proposed as part of the design and development process for surgical robots that are compatible with MRI. Although MR compatibility is a major challenge for development of such robots, no simulation method was known that could predict it. This paper demonstrates the potential of two basic techniques that are useful in predicting the magnetic and electromagnetic compatibility. First, the distortion of the magnetic field caused by the robot can be computed by a finite element method. Simulation of the resonance signal distribution showed good agreement with experimentally obtained signal distributions. Second, a noise source and its strength can be visualized by a spectrum analyzer
Kiyoyuki Chinzei, Kiyoshi Yoshinaka, Toshikatsu Washio
ICRA1
2005 Bone Enhancement Filtering: Application to Sinus Bone Segmentation and Simulation of Pituitary Surgery
Maxime Descoteaux, Michel A. Audette, Kiyoyuki Chinzei, Kaleem Siddiqi
MICCAI3
2004 Precise Evaluation of Positioning Repeatability of MR-Compatible Manipulator Inside MRI
Yoshihiko Koseki, Ron Kikinis, Ferenc A. Jolesz, Kiyoyuki Chinzei
MICCAI (2)4
2004 Needle Force Sensor, Robust and Sensitive Detection of the Instant of Needle Puncture
Toshikatsu Washio, Kiyoyuki Chinzei
MICCAI (2)2
2003 Remote actuation mechanism for mr-compatible manipulator using leverage and parallelogram - workspace analysis, workspace control, and stiffness evaluation
abstract
In this paper, a novel mechanism of remote actuation was proposed and its mechanical problems were discussed. This mechanism consists of leverage and parallelogram mechanism and transmits 3 d.o.f translational and 3 d.o.f rotational motions from the input to output. Such a remote actuation is significantly useful for robotic assist around MRI where the strong and precise magnet is used for imaging, because mutual effect between MRI and robot are inverse proportional to the distance. In this paper, the basic ideas of mechanism were introduced firstly. The discussions of its stiffness and workspace conclude their trade-off. Our new idea of workspace control for mechanical safety is preliminary discussed.
Yoshihiko Koseki, Noriho Koyachi, Tatsuo Arai, Kiyoyuki Chinzei
ICRA4
2002 Measurement of the Tip and Friction Force Acting on a Needle during Penetration
Hiroyuki Kataoka, Toshikatsu Washio, Kiyoyuki Chinzei, Kazuyuki Mizuhara, Christina Simone, Allison M. Okamura
MICCAI (1)3
2002 Endoscope Manipulator for Trans-nasal Neurosurgery, Optimized for and Compatible to Vertical Field Open MRI
Yoshihiko Koseki, Toshikatsu Washio, Kiyoyuki Chinzei, Hiroshi Iseki
MICCAI (1)3
2000 Surgical assist robot for the active navigation in the intraoperative MRI: hardware design issues
abstract
A magnetic resonance (MR) compatible surgical assistance robot system, designed to aid minimally invasive surgical techniques, such as positioning and directing a catheter or a laser pointer, has been built and is under preclinical evaluation. Two specific issues arise in the MR environment: (i) the reduced space in which to place the robot; and (ii) the MR compatibility. The main mechanical body is located above the head of the surgeon, with two rigid, hanging arms that reach into the workspace. This novel configuration contributes to a small occupancy in the workspace and to the MR compatibility. The robot is also carefully designed for safety and sterilization issues. Details of the kinematics and the design of the robot are given, and the MR compatibility is examined. This shows that the robot has no adverse effect on the imaging, even when it is in motion.
Kiyoyuki Chinzei, Nobuhiko Hata, Ferenc A. Jolesz, Ron Kikinis
IROS1
2000 MR Compatible Surgical Assist Robot: System Integration and Preliminary Feasibility Study
Kiyoyuki Chinzei, Nobuhiko Hata, Ferenc A. Jolesz, Ron Kikinis
MICCAI1
2000 Robotic Assist for MR-Guided Surgery Using Leverage and Parallelepiped Mechanism
Yoshihiko Koseki, Kiyoyuki Chinzei, Noriho Koyachi, Tatsuo Arai
MICCAI2
1999 MR Compatibility of Mechatronic Devices: Design Criteria
Kiyoyuki Chinzei, Ron Kikinis, Ferenc A. Jolesz
MICCAI1