Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Peter C. W. Kim

dblp:03/9223 · DBLP profile ↗
← Back
5ranked-venue papers
0as first author
2since 2021 · last 2026
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4 · 1 since 2021Systems, architecture and hardware · 3Graphics, computer vision, multimedia, augmented reality and games · 1 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
3 papers
Trustworthy machine learning · 36% Image recognition and object detection · 36% Vision and language · 11%
Interdisciplinary, comprehensive, and emerging computing
3 papers
Medical and health informatics · 100%
Human-computer interaction and pervasive computing
1 paper
Human-robot interaction · 77% Interaction techniques and input · 23%

Topics — the 8 heaviest of 10, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Machine learning › Trustworthy machine learning › open-world recognition
open-set recognition
0.912025
Recognize Any Surgical Object: Unleashing the Power of Weakly-Supervised Data · ICLR 2025
Computer vision › Image recognition and object detection › medical image analysis
surgical scene understanding
0.912025
Recognize Any Surgical Object: Unleashing the Power of Weakly-Supervised Data · ICLR 2025
Medical and health informatics
surgical robotics
0.432016
Plenoptic cameras in surgical robotics: Calibration, registration, and evaluation · ICRA 2016
Smart Tissue Anastomosis Robot (STAR): Accuracy evaluation for supervisory suturing using near-infrared fluorescent markers · ICRA 2014
Experimental evaluation of contact-less hand tracking systems for tele-operation of surgical tasks · ICRA 2014
Computer vision › Vision and language
weakly supervised vision-language learning
0.312025
Recognize Any Surgical Object: Unleashing the Power of Weakly-Supervised Data · ICLR 2025
Computer vision › 3D vision › range sensing
depth sensing
0.212016
Plenoptic cameras in surgical robotics: Calibration, registration, and evaluation · ICRA 2016
Medical and health informatics › surgical robotics
robot-assisted surgery
0.212016
Plenoptic cameras in surgical robotics: Calibration, registration, and evaluation · ICRA 2016
Human-robot interaction
teleoperation
0.212014
Experimental evaluation of contact-less hand tracking systems for tele-operation of surgical tasks · ICRA 2014
Interaction techniques and input › input sensing › tracking
hand tracking
0.112014
Experimental evaluation of contact-less hand tracking systems for tele-operation of surgical tasks · ICRA 2014

Methods — techniques the papers use, named apart from their topics

weakly supervised learning · 0.9vision-language pretraining · 0.9foundation model · 0.9metric calibration · 0.5hand-eye calibration · 0.5trajectory accuracy measurement · 0.4near-infrared fluorescent markers · 0.4multispectral vision · 0.4latency measurement · 0.4experimental evaluation · 0.4
YearPublicationVenuePosition
2026 Chain-of-Look Spatial Reasoning for Dense Surgical Instrument Counting
abstract
Accurate counting of surgical instruments in Operating Rooms (OR) is a critical prerequisite for ensuring patient safety during surgery. Despite recent progress of large visual-language models and agentic AI, accurately counting such instruments remains highly challenging, particularly in dense scenarios where instruments are tightly clustered. To address this problem, we introduce Chain-of-Look, a novel visual reasoning framework that mimics the sequential human counting process by enforcing a structured visual chain, rather than relying on classic object detection which is unordered. This visual chain guides the model to count along a coherent spatial trajectory, improving accuracy in complex scenes. To further enforce the physical plausibility of the visual chain, we introduce the neighboring loss function, which explicitly models the spatial constraints inherent to densely packed surgical instruments. We also present SurgCount-HD, a new dataset comprising 1,464 high-density surgical instrument images. Extensive experiments demonstrate that our method outperforms state-of-the-art approaches for counting (e.g., CountGD, REC) as well as Multimodality Large Language Models (e.g., Qwen, ChatGPT) in the challenging task of dense surgical instrument counting. The code and dataset is available at https://github.com/rishi1134/CoLSR.git
Rishikesh Bhyri, Brian R. Quaranto, Junsong Yuan 0001, Peter C. W. Kim, Nan Xi
WACV4
2025 Recognize Any Surgical Object: Unleashing the Power of Weakly-Supervised Data
abstract
We present RASO, a foundation model designed to Recognize Any Surgical Object, offering robust open-set recognition capabilities across a broad range of surgical procedures and object classes, in both surgical images and videos. RASO leverages a novel weakly-supervised learning framework that generates tag-image-text pairs automatically from large-scale unannotated surgical lecture videos, significantly reducing the need for manual annotations. Our scalable data generation pipeline gathers 2,200 surgical procedures and produces 3.6 million tag annotations across 2,066 unique surgical tags. Our experiments show that RASO achieves improvements of 2.9 mAP, 4.5 mAP, 10.6 mAP, and 7.2 mAP on four standard surgical benchmarks respectively in zero-shot settings, and surpasses state-of-the-art models in supervised surgical action recognition tasks. We will open-source our code, model, and dataset to facilitate further research.
Jiajie Li 0002, Brian R. Quaranto, Chenhui Xu, Ishan Mishra, Ruiyang Qin, Dancheng Liu, Peter C. W. Kim, Jinjun Xiong
ICLR7
2016 Plenoptic cameras in surgical robotics: Calibration, registration, and evaluation
abstract
Three-dimensional sensing of changing surgical scenes would improve the function of surgical robots. This paper explores the requirements and utility of a new type of depth sensor, the plenoptic camera, for surgical robots. We present a metric calibration procedure for the plenoptic camera and the registration of its coordinate frame to the robot (hand-eye calibration). We also demonstrate the utility in robotic needle insertion and application of sutures in phantoms. The metric calibration accuracy is reported as 1.14 ± 0.80 mm for the plenoptic camera and 1.57 ± 0.90 mm for hand-eye calibration. The accuracy of needle insertion task is 1.79 ± 0.35 mm for the entire robotic system. Additionally, the accuracy of suture placement with the presented system is reported at 1.80 ± 0.43 mm. Finally, we report consistent suture spacing with only 0.11 mm standard deviation between inter-suture distances. The measured accuracy of less than 2 mm with consistent suture spacing is a promising result to provide repeatable leak-free suturing with a robotic tool and a plenoptic depth imager.
Azad Shademan, Ryan S. Decker, Justin D. Opfermann, Simon Léonard, Peter C. W. Kim, Axel Krieger
ICRA5
2014 Experimental evaluation of contact-less hand tracking systems for tele-operation of surgical tasks
abstract
This paper reports an evaluation of contact-less hand tracking sensors for the use of tele-operation, in particular for surgical robotics applications. Two hand tracking systems are investigated: 3Gear Systems interface with the Microsoft KinectTMsensor, and the Leap Motion sensor system. This paper reports an experimental evaluation and comparison of the two systems range, static positioning error, trajectory accuracy of single finger and hand motions, and latency. Latency and trajectory accuracy were found superior using the Leap system. KinectTM/3Gear was found superior when larger range and gesture control are necessary. 3Gear was used in a simulated surgical positioning task and demonstrated an average translational accuracy of 6.2mm. Given the data we have collected, we conclude that neither system, at present, possesses the high level of accuracy and robustness over the required range that would be a prerequisite for use as a medical robotics master.
Yonjae Kim, Peter C. W. Kim, Rebecca Selle, Azad Shademan, Axel Krieger
ICRA2
2014 Smart Tissue Anastomosis Robot (STAR): Accuracy evaluation for supervisory suturing using near-infrared fluorescent markers
abstract
This paper specifies and evaluates the accuracy of the Smart Tissue Anastomosis Robot (STAR). The STAR is a proof of concept vision-guided robotic system equipped with an actuated laparoscopic suturing tool and a multispectral vision system. The STAR supports image-based suturing commands and is capable of detecting near-infrared fluorescent (NIRF) markers that provide reliable visual segmentation and tracking. The paper reports the best case scenario accuracy specifications of the STAR as derived from its configuration and calibration parameters. We also evaluate experimentally the effects of overlaying NIRF markers on the accuracy of the STAR when these markers are used as the source of image-based commands and we compare these results to the accuracy of the STAR with image-based commands generated from plain color images. Our results demonstrate that the STAR is able to place sutures on a planar phantom with an average accuracy of 0.5 mm with a standard deviation of 0.2 mm and that NIRF markers have no statistically significant adverse effect on the accuracy.
Simon Léonard, Azad Shademan, Yonjae Kim, Axel Krieger, Peter C. W. Kim
ICRA5