Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Hao Su 0002

dblp:09/4945-2 · DBLP profile ↗
← Back
8ranked-venue papers
4as first author
6since 2021 · last 2026
0000-0003-3299-7418ORCID · conflict

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3 · 3 first-author · 1 since 2021Applied, interdisciplinary, general and emerging computing · 3 · 1 first-author · 3 since 2021Systems, architecture and hardware · 2 · 2 first-authorHuman-computer interaction and ubiquitous computing · 2 · 2 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
1 paper
Accessibility and assistive technology · 75% Human-robot interaction · 25%
Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%
Artificial intelligence
2 papers
Robot manipulation · 70% Motion planning and robot control · 30%

Topics — the 10 heaviest of 10, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
image-guided intervention
0.612022
State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions · Proc. IEEE 2022
Medical and health informatics › surgical navigation
intraoperative imaging
0.612022
State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions · Proc. IEEE 2022
Accessibility and assistive technology
assistive technology
0.612022
Modeling and Stiffness-Based Continuous Torque Control of Lightweight Quasi-Direct-Drive Knee Exoskeletons for Versatile Walking Assistance · IEEE Trans. Robotics 2022
Human-robot interaction › wearable robot
exoskeleton
0.612022
Modeling and Stiffness-Based Continuous Torque Control of Lightweight Quasi-Direct-Drive Knee Exoskeletons for Versatile Walking Assistance · IEEE Trans. Robotics 2022
Accessibility and assistive technology › locomotion assistance
gait assistance
0.612022
Modeling and Stiffness-Based Continuous Torque Control of Lightweight Quasi-Direct-Drive Knee Exoskeletons for Versatile Walking Assistance · IEEE Trans. Robotics 2022
Accessibility and assistive technology › assistive technology
knee exoskeleton
0.612022
Modeling and Stiffness-Based Continuous Torque Control of Lightweight Quasi-Direct-Drive Knee Exoskeletons for Versatile Walking Assistance · IEEE Trans. Robotics 2022
Robotics › Robot manipulation › medical robotics
MRI-compatible robot
0.212022
State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions · Proc. IEEE 2022
Robotics › Robot manipulation › medical robotics
needle steering
0.112011
Real-time MRI-guided needle placement robot with integrated fiber optic force sensing · ICRA 2011
Robotics › Motion planning and robot control
robot control
0.112011
Real-time MRI-guided needle placement robot with integrated fiber optic force sensing · ICRA 2011
Medical and health informatics › medical robotics
robot-assisted intervention
0.012011
Real-time MRI-guided needle placement robot with integrated fiber optic force sensing · ICRA 2011

Methods — techniques the papers use, named apart from their topics

multimodality sensing · 1.1instrument tracking · 1.1stiffness modeling · 0.6quasi-direct drive actuation · 0.6continuous torque control · 0.6piezoelectric actuation · 0.2fiber optic force sensing · 0.2fabry-perot interferometer · 0.2
YearPublicationVenuePosition
2026 Physics-informed blind wavelet deconvolution transfer network for cross-machine bearing fault diagnosis
Hao Su 0002, Hongfu Zhang, Xiaoan Yan
Eng. Appl. Artif. Intell.1
2026 Toward Generalist Neural Motion Planners for Robotic Manipulators: Challenges and Opportunities
abstract
State-of-the-art generalist manipulation policies have enabled the deployment of robotic manipulators in unstructured human environments. However, these frameworks struggle in cluttered environments primarily because they utilize auxiliary modules for low-level motion planning and control. Motion planning remains challenging due to the high dimensionality of the robot’s configuration space and the presence of workspace obstacles. Neural motion planners have enhanced motion planning efficiency by offering fast inference and effectively handling the inherent multi-modality of the motion planning problem. Despite such benefits, current neural motion planners often struggle to generalize to unseen, out-of-distribution planning settings. This paper reviews and analyzes the state-of-the-art neural motion planners, highlighting both their benefits and limitations. It also outlines a path toward establishing generalist neural motion planners capable of handling domain-specific challenges. For a list of the reviewed papers, please refer to https://davoodsz.github.io/planning-manip-survey.github.io/.
Davood Soleymanzadeh, Ivan Lopez-Sanchez, Hao Su 0002, Yunzhu Li, Xiao Liang 0012, Minghui Zheng
IEEE Trans Autom. Sci. Eng.3
2026 Optimizing Sensor and Data Selection on Lower Limbs via Deep Learning for Real-Time Human Activity Recognition
abstract
Real-time human activity recognition (HAR) is crucial for adaptive control in lower limb exoskeletons, yet achieving an optimal balance between accuracy, latency, and sensor complexity remains challenging. This study's key idea is to systematically evaluate sensor selection and data modalities for real-time HAR using deep neural networks with ultra-short 50 ms sliding windows. Leveraging a dataset from 21 subjects performing six locomotion activities and employing three deep learning models (MLP, LSTM, CNN-LSTM), we assess multiple sensor combinations, including joint angle data, derived angular velocities, and inertial measurements, and quantify their trade-offs across accuracy, latency, and model complexity. Our analysis reveals that bilateral joint angles from hip, knee, and ankle achieve 98.98% accuracy, significantly outperforming unilateral sensor setups. Adding a thigh-mounted IMU further elevates accuracy to 99.23%, highlighting the advantages of multimodal sensor fusion. Additionally, incorporating derived joint angular velocities enhances accuracy, with up to 15% increase when using single-joint bilateral inverse kinematics data. Even a minimal configuration, such as bilateral hip joints with derived angular velocities, achieves over 94% accuracy, offering practical solutions for low-power wearable systems. These findings establish actionable design principles for HAR-driven control in assistive robotics and mobile health applications.
Zihang You, Neethan Ratnakumar, Bo Shen 0005, Hao Su 0002, Xianlian Zhou 0001
IEEE Trans. Hum. Mach. Syst.4
2025 Equilibrium Torque Control-Based Lower-Limb Exoskeleton Assistance With Memory-Enhanced Gait Prediction and Real-Time Learning
abstract
The control of lower-limb exoskeletons plays a crucial role in determining the effectiveness of walking assistance, but how to generate a reference signal still poses a significant challenge. Many existing approaches involve offline training and classifiers or depend on prefabricated models, lacking the adaptability needed to support diverse users and real-time scenarios with varying gait cycles. Meanwhile, balancing intervention on human limbs between compliance and assistance during learning is still an open problem. To address these issues, this article proposes a real-time learning method for walking assistance without classifiers, automatically adapting to alterations in motion patterns. The control law, based on adaptive admittance control and the equilibrium state, ensures stable assistance during learning with intuitive parameter tuning and allows for switching of gait during assistance. Utilizing selective memory recursive least squares in a neural network enables rapid learning and precise prediction of human users’ motion intention, without pretraining. Experimental results demonstrate that our approach achieves a prediction error within 6° after half a minute of learning with a prediction ahead time of 120 ms, outperforming classic approaches. The assistance performance is consistent despite varied control parameters, indicating a certain level of robustness.
Yiming Fei, Hao Su 0002, Yanan Li 0001
IEEE Trans. Syst. Man Cybern. Syst.3
2022 State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions
abstract
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of target anatomy, surrounding tissue, and instrumentation, but there are significant challenges in harnessing it for effectively guiding interventional procedures. Challenges include the strong static magnetic field, rapidly switching magnetic field gradients, high-power radio frequency pulses, sensitivity to electrical noise, and constrained space to operate within the bore of the scanner. MRI has a number of advantages over other medical imaging modalities, including no ionizing radiation, excellent soft-tissue contrast that allows for visualization of tumors and other features that are not readily visible by other modalities, true 3-D imaging capabilities, including the ability to image arbitrary scan plane geometry or perform volumetric imaging, and capability for multimodality sensing, including diffusion, dynamic contrast, blood flow, blood oxygenation, temperature, and tracking of biomarkers. The use of robotic assistants within the MRI bore, alongside the patient during imaging, enables intraoperative MR imaging (iMRI) to guide a surgical intervention in a closed-loop fashion that can include tracking of tissue deformation and target motion, localization of instrumentation, and monitoring of therapy delivery. With the ever-expanding clinical use of MRI, MRI-compatible robotic systems have been heralded as a new approach to assist interventional procedures to allow physicians to treat patients more accurately and effectively. Deploying robotic systems inside the bore synergizes the visual capability of MRI and the manipulation capability of robotic assistance, resulting in a closed-loop surgery architecture. This article details the challenges and history of robotic systems intended to operate in an MRI environment and outlines promising clinical applications and associated state-of-the-art MRI-compatible robotic systems and technology for making this possible.
Hao Su 0002, Ka-Wai Kwok, Kevin Cleary, Iulian Iordachita, Murat Cenk Cavusoglu, Jaydev P. Desai, Gregory S. Fischer
Proc. IEEE1
2022 Modeling and Stiffness-Based Continuous Torque Control of Lightweight Quasi-Direct-Drive Knee Exoskeletons for Versatile Walking Assistance
abstract
State-of-the-art exoskeletons are typically limited by low control bandwidth and small range stiffness of actuators which are based on high gear ratios and elastic components (e.g., series elastic actuators). Furthermore, most exoskeletons are based on discrete gait phase detection and/or discrete stiffness control resulting in discontinuous torque profiles. To fill these two gaps, we developed a portable lightweight knee exoskeleton using quasi-direct drive (QDD) actuation that provides 14 Nm torque (36.8% biological joint moment for overground walking). This paper presents 1) stiffness modeling of torque-controlled QDD exoskeletons and 2) stiffness-based continuous torque controller that estimates knee joint moment in real-time. Experimental tests found the exoskeleton had high bandwidth of stiffness control (16 Hz under 100 Nm/rad) and high torque tracking accuracy with 0.34 Nm Root Mean Square (RMS) error (6.22%) across 0-350 Nm/rad large range stiffness. The continuous controller was able to estimate knee moments accurately and smoothly for three walking speeds and their transitions. Experimental results with 8 able-bodied subjects demonstrated that our exoskeleton was able to reduce the muscle activities of all 8 measured knee and ankle muscles by 8.60%-15.22% relative to unpowered condition, and two knee flexors and one ankle plantar flexor by 1.92%-10.24% relative to baseline (no exoskeleton) condition.
Tzu-Hao Huang, Shuangyue Yu, Mhairi MacLean, Junxi Zhu, Antonio Di Lallo, Chunhai Jiao, Thomas C. Bulea, Minghui Zheng, Hao Su 0002
IEEE Trans. Robotics10
2012 A MRI-guided concentric tube continuum robot with piezoelectric actuation: A feasibility study
abstract
This paper presents a versatile magnetic resonance imaging (MRI) compatible concentric tube continuum robotic system. The system enables MR image-guided placement of a curved, steerable active cannula. It is suitable for a variety of clinical applications including image-guided neurosurgery and percutaneous interventions, along with procedures that involve accessing a desired image target, through a curved trajectory. This 6 degree-of-freedom (DOF) robotic device is piezoelectrically actuated to provide precision motion with joint-level precision of better than 0.03mm, and is fully MRI-compatible allowing simultaneous robotic motion and imaging with no image quality degradation. The MRI compatibility of the robot has been evaluated under 3 Tesla MRI using standard prostate imaging sequences, with an average signal to noise ratio loss of less than 2% during actuator motion. The accuracy of active cannula control was evaluated in benchtop trials using an external optical tracking system with RMS error in tip placement of 1.00mm. Preliminary phantom trials of three active cannula placements in the MRI scanner showed cannula trajectories that agree with our kinematic model, with a RMS tip placement error of 0.61 - 2.24 mm.
Hao Su 0002, Diana C. Cardona, Weijian Shang, Alexander Camilo, Gregory A. Cole, D. Caleb Rucker, Robert J. Webster III, Gregory S. Fischer
ICRA1
2011 Real-time MRI-guided needle placement robot with integrated fiber optic force sensing
abstract
This paper presents the first prototype of a magnetic resonance imaging (MRI) compatible piezoelectric actuated robot integrated with a high-resolution fiber optic sensor for prostate brachytherapy with real-time in situ needle steering capability in 3T MRI. The 6-degrees-of-freedom (DOF) robot consists of a modular 3-DOF needle driver with fiducial tracking frame and a 3-DOF actuated Cartesian stage. The needle driver provides needle cannula rotation and translation (2-DOF) and stylet translation (1-DOF). The driver mimics the manual physician gesture by two point grasping. To render proprioception associated with prostate interventions, a Fabry Perot interferometer based fiber optic strain sensor is designed to provide high-resolution axial needle insertion force measurement and is robust to large range of temperature variation. The paper explains the robot mechanism, controller design, optical modeling and opto-mechanical design of the force sensor. MRI compatibility of the robot is evaluated under 3T MRI using standard prostate imaging sequences and average signal noise ratio (SNR) loss is limited to 2% during actuator motion. A dynamic needle insertion is performed and bevel tip needle steering capability is demonstrated under continuous real-time MRI guidance, both with no visually identifiable interference during robot motion. Fiber optic sensor calibration validates the theoretical modeling with satisfactory sensing range and resolution for prostate intervention.
Hao Su 0002, Michael Zervas, Gregory A. Cole, Cosme Furlong, Gregory S. Fischer
ICRA1