Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Jacob Bergsland

dblp:115/5206 · DBLP profile ↗
← Back
6ranked-venue papers
0as first author
3since 2021 · last 2022
0000-0002-3101-4064ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 4 · 2 since 2021Computer networks · 1 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Bioinformatics and computational biology · 50% Computational science and engineering · 50%

Topics — the 1 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Bioinformatics and computational biology
molecular communication
0.512021
Cardiac Bio-Nanonetwork: Extracellular Matrix Modeling for the Propagation of Extracellular Vesicles · SenSys 2021

Methods — techniques the papers use, named apart from their topics

partial differential equations · 0.5finite element method · 0.5
YearPublicationVenuePosition
2022 Accurate Real-time Polyp Detection in Videos from Concatenation of Latent Features Extracted from Consecutive Frames
abstract
An efficient deep learning model that can be implemented in real-time for polyp detection is crucial to reducing polyp miss-rate during screening procedures. Convolutional neural networks (CNNs) are vulnerable to small changes in the input image. A CNN-based model may miss the same polyp appearing in a series of consecutive frames and produce unsubtle detection output due to changes in camera pose, lighting condition, light reflection, etc. In this study, we attempt to tackle this problem by integrating temporal information among neighboring frames. We propose an efficient feature concatenation method for a CNN-based encoder-decoder model without adding complexity to the model. The proposed method incorporates extracted feature maps of previous frames to detect polyps in the current frame. The experimental results demonstrate that the proposed method of feature concatenation improves the overall performance of automatic polyp detection in videos. The following results are obtained on a public video dataset: sensitivity 90.94%, precision 90.53%, and specificity 92.46%.
Hemin Ali Qadir, Younghak Shin, Jacob Bergsland, Ilangko Balasingham
BIBM3
2021 Cardiac Bio-Nanonetwork: Extracellular Matrix Modeling for the Propagation of Extracellular Vesicles
abstract
Novel non-invasive procedures, such as targeted drug delivery may enhance the efficacy of treatments of cardiac disorders. A possible solution is to utilize a molecular communication paradigm based on cell-derived nano-sized vesicles --- extracellular vesicles (EVs) --- that can be used as vehicles for therapeutic biological cargo. EVs can be engineered with specific cell-targeting transmembrane proteins to improve their pharmacokinetic properties. Here, we study the transport of EVs in a non-cellular component of cardiac tissue referred to as the cardiac extracellular matrix (ECM). We inspect EV diffusion and advection in cardiac ECM by considering 1) tortuosity, which describes the convoluted pathway of EV transportation, 2) volume fraction, which characterizes the porosity of the cardiac ECM; and 3) EV degradation according to their half-life in the body. We analytically describe the EV transportation dynamics via a partial differential equation and solve it numerically using finite element methods. The presented findings indicate that EV propagation is dependent on the cardiac ECM hindrance sources. Bulk flow in the cardiac ECM, however, can mediate the EVs to reach their distant target cells.
Hamid Khoshfekr Rudsari, Mladen Veletic, Jacob Bergsland, Ilangko Balasingham
SenSys3
2021 Toward real-time polyp detection using fully CNNs for 2D Gaussian shapes prediction
abstract
To decrease colon polyp miss-rate during colonoscopy, a real-time detection system with high accuracy is needed. Recently, there have been many efforts to develop models for real-time polyp detection, but work is still required to develop real-time detection algorithms with reliable results. We use single-shot feed-forward fully convolutional neural networks (F-CNN) to develop an accurate real-time polyp detection system. F-CNNs are usually trained on binary masks for object segmentation. We propose the use of 2D Gaussian masks instead of binary masks to enable these models to detect different types of polyps more effectively and efficiently and reduce the number of false positives. The experimental results showed that the proposed 2D Gaussian masks are efficient for detection of flat and small polyps with unclear boundaries between background and polyp parts. The masks make a better training effect to discriminate polyps from the polyp-like false positives. The proposed method achieved state-of-the-art results on two polyp datasets. On the ETIS-LARIB dataset we achieved 86.54% recall, 86.12% precision, and 86.33% F1-score, and on the CVC-ColonDB we achieved 91% recall, 88.35% precision, and F1-score 89.65%.
Hemin Ali Qadir, Younghak Shin, Johannes Solhusvik, Jacob Bergsland, Lars Aabakken, Ilangko Balasingham
Medical Image Anal.4
2020 Improving Automatic Polyp Detection Using CNN by Exploiting Temporal Dependency in Colonoscopy Video
abstract
Automatic polyp detection has been shown to be difficult due to various polyp-like structures in the colon and high interclass variations in polyp size, color, shape, and texture. An efficient method should not only have a high correct detection rate (high sensitivity) but also a low false detection rate (high precision and specificity). The state-of-the-art detection methods include convolutional neural networks (CNN). However, CNNs have shown to be vulnerable to small perturbations and noise; they sometimes miss the same polyp appearing in neighboring frames and produce a high number of false positives. We aim to tackle this problem and improve the overall performance of the CNN-based object detectors for polyp detection in colonoscopy videos. Our method consists of two stages: a region of interest (RoI) proposal by CNN-based object detector networks and a false positive (FP) reduction unit. The FP reduction unit exploits the temporal dependencies among image frames in video by integrating the bidirectional temporal information obtained by RoIs in a set of consecutive frames. This information is used to make the final decision. The experimental results show that the bidirectional temporal information has been helpful in estimating polyp positions and accurately predict the FPs. This provides an overall performance improvement in terms of sensitivity, precision, and specificity compared to conventional false positive learning method, and thus achieves the state-of-the-art results on the CVC-ClinicVideoDB video data set.
Hemin Ali Qadir, Ilangko Balasingham, Johannes Solhusvik, Jacob Bergsland, Lars Aabakken, Younghak Shin
IEEE J. Biomed. Health Informatics4
2016 Experimental ultra wideband path loss models for implant communications
abstract
Ultra wideband (UWB) signals possess characteristics that may enable high data rate communications with deeply implanted medical sensors and actuators. Nevertheless, this application could be hindered in part by international spectrum regulations, which restrict UWB communications to 3.1-10.6 GHz where propagation conditions through the human body are rather unfavorable. Therefore, for the proper feasibility assessment and design of implant communications using UWB signals, accurate models of the radio channel are of utmost importance. Hence, we present UWB path loss models for the two most commonly used implant communication scenarios, i.e., in-body to on-body (IB2OB) and in-body to off-body (IB2OFF). These models were extracted from in vivo measurements in the abdominal cavity within 3.1-8.5 GHz using a living porcine subject. A thorough comparison between this modeling approach and channel measurements using a homogeneous phantom, which mimics the electromagnetic behaviour of muscle tissue, is presented too. Measurements in a homogeneous propagation medium are simpler to perform, but they fail to capture several physiological effects observed in a living subject. Thus, we measured the deviation between the phantom-based and in-vivo-based path loss models. In general, phantom measurements yielded a more pessimistic estimation of the path loss. We provide the correction factors to adjust easy-to-perform phantom-based measurements to more realistic path loss values, which can assist the biomedical engineer in the early stages of design and testing of wireless implantable devices.
Concepcion Garcia-Pardo, Alejandro Fornes-Leal, Narcís Cardona, Raúl Chávez-Santiago, Jacob Bergsland, Ilangko Balasingham, Sverre Brovoll, Øyvind Aardal, Svein-Erik Hamran, Rafael Palomar
PIMRC5
2015 In-Body to On-Body Ultrawideband Propagation Model Derived From Measurements in Living Animals
abstract
Ultrawideband (UWB) radio technology for wireless implants has gained significant attention. UWB enables the fabrication of faster and smaller transceivers with ultralow power consumption, which may be integrated into more sophisticated implantable biomedical sensors and actuators. Nevertheless, the large path loss suffered by UWB signals propagating through inhomogeneous layers of biological tissues is a major hindering factor. For the optimal design of implantable transceivers, the accurate characterization of the UWB radio propagation in living biological tissues is indispensable. Channel measurements in phantoms and numerical simulations with digital anatomical models provide good initial insight into the expected path loss in complex propagation media like the human body, but they often fail to capture the effects of blood circulation, respiration, and temperature gradients of a living subject. Therefore, we performed UWB channel measurements within 1-6 GHz on two living porcine subjects because of the anatomical resemblance with an average human torso. We present for the first time, a path loss model derived from these in vivo measurements, which includes the frequency-dependent attenuation. The use of multiple on-body receiving antennas to combat the high propagation losses in implant radio channels was also investigated.
Pål Anders Floor, Raúl Chávez-Santiago, Sverre Brovoll, Øyvind Aardal, Jacob Bergsland, Ole-Johannes H. N. Grymyr, Per Steinar Halvorsen, Rafael Palomar, Dirk Plettemeier, Svein-Erik Hamran, Tor A. Ramstad, Ilangko Balasingham
IEEE J. Biomed. Health Informatics5