Demo Data from EDBT 2026 / reviewers in the wild / expert
Ryan J. Halter
dblp:115/8195
· DBLP profile ↗
16ranked-venue papers
1as first author
0since 2021 · last 2020
0000-0003-0222-3948ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 11 · 1 first-authorComputer networks · 5
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
5 papers |
Wearable and physiological sensing · 56% Health and well-being technologies · 32% Personal fabrication and tangible interfaces · 13% | |
| Computer architecture, parallel and distributed computing, and storage systems
2 papers |
Embedded and real-time systems · 77% Energy-efficient computing · 23% |
Topics — the 9 heaviest of 9, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Wearable and physiological sensing
wearable platform |
0.5 | 2 | 2016 | The Amulet Wearable Platform: Demo Abstract · SenSys 2016 Amulet: An Energy-Efficient, Multi-Application Wearable Platform · SenSys 2016 |
Embedded and real-time systems › mobile computing
energy-efficient wearable |
0.5 | 2 | 2016 | The Amulet Wearable Platform: Demo Abstract · SenSys 2016 Amulet: An Energy-Efficient, Multi-Application Wearable Platform · SenSys 2016 |
Health and well-being technologies
dietary monitoring |
0.3 | 1 | 2017 | Poster: Auracle: A Wearable Device for Detecting and Monitoring Eating Behavior · MobiSys 2017 |
Personal fabrication and tangible interfaces › digital craft
digital jewellery |
0.2 | 1 | 2014 | Poster: Enabling computational jewelry for mHealth applications · MobiSys 2014 |
Health and well-being technologies
mobile health |
0.2 | 1 | 2014 | Poster: Enabling computational jewelry for mHealth applications · MobiSys 2014 |
Wearable and physiological sensing
user identification |
0.2 | 1 | 2014 | A wearable system that knows who wears it · MobiSys 2014 |
Energy-efficient computing › battery management
battery lifetime optimization |
0.1 | 2 | 2016 | The Amulet Wearable Platform: Demo Abstract · SenSys 2016 Amulet: An Energy-Efficient, Multi-Application Wearable Platform · SenSys 2016 |
Wearable and physiological sensing
earable sensing |
0.1 | 1 | 2017 | Poster: Auracle: A Wearable Device for Detecting and Monitoring Eating Behavior · MobiSys 2017 |
Wearable and physiological sensing
body area network |
0.1 | 1 | 2014 | A wearable system that knows who wears it · MobiSys 2014 |
Methods — techniques the papers use, named apart from their topics
runtime system · 0.5resource usage optimization · 0.5firmware toolchain · 0.5app isolation · 0.5
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2020 | Continuous Detection of Physiological Stress with Commodity HardwareabstractTimely detection of an individual’s stress level has the potential to improve stress management, thereby reducing the risk of adverse health consequences that may arise due to mismanagement of stress. Recent advances in wearable sensing have resulted in multiple approaches to detect and monitor stress with varying levels of accuracy. The most accurate methods, however, rely on clinical-grade sensors to measure physiological signals; they are often bulky, custom made, and expensive, hence limiting their adoption by researchers and the general public. In this article, we explore the viability of commercially available off-the-shelf sensors for stress monitoring. The idea is to be able to use cheap, nonclinical sensors to capture physiological signals and make inferences about the wearer’s stress level based on that data. We describe a system involving a popular off-the-shelf heart rate monitor, the Polar H7; we evaluated our system with 26 participants in both a controlled lab setting with three well-validated stress-inducing stimuli and in free-living field conditions. Our analysis shows that using the off-the-shelf sensor alone, we were able to detect stressful events with an F 1-score of up to 0.87 in the lab and 0.66 in the field, on par with clinical-grade sensors. Varun Mishra 0001, Gunnar Pope, Sarah E. Lord, Stephanie Lewia, Byron Lowens, Kelly Caine, Sougata Sen, Ryan J. Halter, David Kotz |
ACM Trans. Comput. Heal. | 8 |
| 2020 | Phantom Studies of Fused-Data TREIT Using Only Biopsy-Probe ElectrodesabstractTransrectal electrical impedance tomography (TREIT) is a novel imaging modality being developed for prostate biopsy guidance and cancer characterization. We describe a novel fused-data TREIT (fd-TREIT) system and approach developed to improve imaging robustness and evaluate it on challenging clinically-representative phantoms. The new approach incorporates 8 electrodes (in 2 rows) on a biopsy probe (BP) and 12 electrodes on the face of a transrectal ultrasound (TRUS) probe and includes a biopsy gun, instrument tracking, 3D-printed needle guide, and EIT hardware and software. The approach was evaluated via simulation, a series of prostate-shaped gel phantoms, and an ex vivo bovine tissue sample using only absolute reconstructions. The simulations surprisingly found that using only biopsy-probe electrode measurements, i.e. omitting TRUS-probe electrode measurements, significantly improves robustness to noise thus leading to simpler modeling and significant decreases in computational times (~13x speed-up/reconstructions in ~27 minutes). The gel phantom experiments resulted in reconstructions with area under the curve (AUC) values extracted from receiver operator characteristic curves of >0.85 for 4 out of the 5 tests, and when incorporating inclusion boundaries resulted in absolute reconstructions yielding 1.9% and 12.2% average percent errors for 3 consistent tests and all 5 tests, respectively. Ex vivo bovine tests revealed qualitatively that the fd-TREIT approach can largely discriminate a complex adipose and muscle interface in a realistic setting using data from 9 biopsy probe states (biopsy core locations). The algorithms developed here on challenging phantoms suggest strong promise for this technology to aid in imaging during routine 12-core biopsies. Ethan K. Murphy, Alicia Everitt, Ryan J. Halter |
IEEE Trans. Medical Imaging | 4 |
| 2019 | Toward Electrical Impedance Tomography Coupled Ultrasound Imaging for Assessing Muscle HealthabstractThis paper establishes for the first time that a coupled ultrasound (US) and electrical impedance tomography (EIT) system can serve as a non-invasive, spatially localized approach to extract clinically relevant muscle properties. The US/EIT system represents a potential enhancement to electrical impedance myography (EIM), which has shown promise as a non-invasive technology that may have important clinical use in indicating neuromuscular disease status and as a diagnostic tool. A 2.5D EIT algorithm evaluated on simulation, measured phantoms, and measured patient data was studied to evaluate US/EIT's ability to distinguish different aspects of muscle tissue. Simulated and phantom experiments revealed the depths of distinguishability of 3.2 and 4.2 mm in simulation for 10% and 20% changes in muscle properties, respectively, and 3.6 mm in measured phantom experiments assuming a 12% muscle conductivity change. Reconstructions from the patient data established that there were consistent differences 1) between longitudinal (along) and transverse (across) muscle conductivity reconstructions at frequencies of 40 and 80 kHz and 2) side-by-side comparison between healthy and diseased tissue in terms of conductivity, permittivity, and phase at 40 and 80 kHz. Comparisons were made between the EIT reconstructed values and electrical impedance spectroscopy (EIS) measurements (an available surrogate in place of standard EIM measurements) made with the US/EIT system, wherein 1) EIS and EIT show similar sensitivity to longitudinal and transverse differences and 2) EIT showed a more consistent ability to differentiate healthy and diseased tissue. These results suggest that US/EIT appears very promising for non-invasive and spatially localized diagnosis of muscle health. Ethan K. Murphy, Joseph Skinner, Maria Martucci, Seward B. Rutkove, Ryan J. Halter |
IEEE Trans. Medical Imaging | 5 |
| 2018 | GeriActive: Wearable app for monitoring and encouraging physical activity among older adultsabstractThe ability to monitor a person's level of daily activity can inform self-management of physical activity and assist in augmenting behavioral interventions. For older adults, the importance of regular physical activity is critical to reduce the risk of long-term disability. In this work, we present GeriActive, an application on the Amulet wrist-worn device that monitors in real time older adults' daily activity levels (low, moderate and vigorous), which we categorized using metabolic equivalents (METs). The app implements an activity-level detection model we developed using a linear Support Vector Machine (SVM). We trained our model using data from volunteer subjects (n=29) who performed common physical activities (sit, stand, lay down, walk and run) and obtained an accuracy of 94.3% with leave-one-subject-out (LOSO) cross-validation. We ran a week-long field study to evaluate the usability and battery life of the GeriActive system where 5 older adults wore the Amulet as it monitored their activity level. Their feedback showed that our system has the potential to be usable and useful. Our evaluation further revealed a battery life of at least 1 week. The results are promising, indicating that the app may be used for activity-level monitoring by individuals or researchers for health delivery interventions that could improve the health of older adults. George Boateng, John A. Batsis, Patrick Proctor, Ryan J. Halter, David Kotz |
BSN | 4 |
| 2018 | An ultra-low resource wearable EDA sensor using wavelet compressionabstractThis study presents an ultra-low resource platform for physiological sensing that uses on-chip wavelet compression to enable long-term recording of electrodermal activity (EDA) within a 64kB microcontroller. The design is implemented on a wearable platform and provides improvements in size and power compared to existing wearable technologies and was used in a lab setting to monitor EDA of 27 participants throughout a stress induction protocol. We demonstrate the device's sensitivity to stress induction by providing descriptive statistics of 8 common EDA signal features for each stressor of the experiment. To the best of our knowledge, this is the first time a generic, 16-bit microcontroller (MCU) has been used to record real-time physiological signals on a wearable platform without the use of external memory chips or wireless transmission for extended periods of time. The compression techniques described can lead to reductions in size, power, and cost of wearable biosensors with little or no modifications to existing sensor hardware and could be valuable for applications interested in monitoring long-term physiological trends at lower data rates and memory requirements. Gunnar Pope, Varun Mishra 0001, Stephanie Lewia, Byron Lowens, David Kotz, Sarah E. Lord, Ryan J. Halter |
BSN | 7 |
| 2017 | Poster: Auracle: A Wearable Device for Detecting and Monitoring Eating BehaviorabstractChronic disease is one of the most pressing health challenges facing the United States (and an increasing set of other countries). The onset or progression of diseases like obesity, diabetes, and metabolic disorder are strongly related to eating behavior, and scientists are still trying to fully understand the complex mixture of diet, exercise, genetics, sociocultural context, and physical environment that lead to these diseases. Health science, however, has no effective means for automatically measuring eating behavior in free-living conditions. The Auracle aims to be a wearable earpiece that detects eating behavior, to be fielded by health-science researchers in their efforts to study eating behavior and ultimately to develop interventions useful to individuals striving to address chronic disease related to eating. Shengjie Bi, Ellen Davenport, Jun Gong 0002, Ronald A. Peterson, Joseph Skinner, Kevin M. Storer, Kelly Caine, Ryan J. Halter, David Kotz, Kofi M. Odame, Jacob Sorber, Xing-Dong Yang |
MobiSys | 9 |
| 2017 | Absolute Reconstructions Using Rotational Electrical Impedance Tomography for Breast Cancer ImagingabstractA rotational Electrical Impedance Tomography (rEIT) methodology is described and shown to produce spatially accurate absolute reconstructions with improved image contrast and an improved ability to distinguish closely spaced inclusions compared to traditional EIT on data recorded from cylindrical and breast-shaped tanks. Rotations of the tank without altering the interior conductivity distribution are used to produce the rEIT data. Quantitatively, rEIT was able to distinguish two inclusions that were 1.5 cm closer together than traditional EIT could achieve for inclusions placed 2 to 3 cm from the center for the cylindrical tank, and rEIT was able to distinguish two tumor-like inclusions where traditional EIT could not reliably do so. Mathematical analysis showed that rEIT improves the number of stable singular vectors by up to 4.2 and 4.7 times than that of traditional EIT for the cylindrical and breast-shaped tanks, respectively, which is an indication of improved resolution. Direct investigations into measurements revealed minimum rotation angles that should yield data uncorrupted by noise. Two inverse approaches (one that inverts then fuses the data (I/DF) and one that fuses the data then inverts (DF/I)) and two mesh modeling approaches were considered. It was found that DF/I produces far better results compared to I/DF and a rotated-mesh approach produces further improvements. The ability to obtain improved absolute reconstructions using rEIT on a practical clinical scenario (breast-shaped tank experiment) is an important step towards using rEIT to improve previous EIT results in medical applications. Ethan K. Murphy, Aditya Mahara, Ryan J. Halter |
IEEE Trans. Medical Imaging | 3 |
| 2016 | Amulet: An Energy-Efficient, Multi-Application Wearable PlatformabstractWearable technology enables a range of exciting new applications in health, commerce, and beyond. For many important applications, wearables must have battery life measured in weeks or months, not hours and days as in most current devices. Our vision of wearable platforms aims for long battery life but with the flexibility and security to support multiple applications. To achieve long battery life with a workload comprising apps from multiple developers, these platforms must have robust mechanisms for app isolation and developer tools for optimizing resource usage. Josiah D. Hester, Travis Peters, Tianlong Yun, Ronald A. Peterson, Joseph Skinner, Bhargav Golla, Kevin M. Storer, Steven Hearndon, Kevin Freeman, Sarah E. Lord, Ryan J. Halter, David Kotz, Jacob Sorber |
SenSys | 11 |
| 2016 | The Amulet Wearable Platform: Demo AbstractabstractIn this demonstration we present the Amulet Platform; a hardware and software platform for developing energy- and resource-efficient applications on multi-application wearable devices. This platform, which includes the Amulet Firmware Toolchain, the Amulet Runtime, the ARP-View graphical tool, and open reference hardware, efficiently protects applications from each other without MMU support, allows developers to interactively explore how their implementation decisions impact battery life without the need for hardware modeling and additional software development, and represents a new approach to developing long-lived wearable applications. We envision the Amulet Platform enabling long-duration experiments on human subjects in a wide variety of studies. Josiah D. Hester, Travis Peters, Tianlong Yun, Ronald A. Peterson, Joseph Skinner, Bhargav Golla, Kevin M. Storer, Steven Hearndon, Sarah E. Lord, Ryan J. Halter, David Kotz, Jacob Sorber |
SenSys | 10 |
| 2016 | An Inverse Problems Approach to MR-EPT Image ReconstructionabstractMagnetic Resonance-Electrical Properties Tomography (MR-EPT) is an imaging modality that maps the spatial distribution of the electrical conductivity and permittivity using standard MRI systems. The presence of a body within the scanner alters the RF field, and by mapping these alterations it is possible to recover the electrical properties. The field is time-harmonic, and can be described by the Helmholtz equation. Approximations to this equation have been previously used to estimate conductivity and permittivity in terms of first or second derivatives of RF field data. Using these same approximations, an inverse approach to solving the MR-EPT problem is presented here that leverages a forward model for describing the magnitude and phase of the field within the imaging domain, and a fitting approach for estimating the electrical properties distribution. The advantages of this approach are that 1) differentiation of the measured data is not required, thus reducing noise sensitivity, and 2) different regularization schemes can be adopted, depending on prior knowledge of the distribution of conductivity or permittivity, leading to improved image quality. To demonstrate the developed approach, both Quadratic (QR) and Total Variation (TV) regularization methods were implemented and evaluated through numerical simulation and experimentally acquired data. The proposed inverse approach to MR-EPT reconstruction correctly identifies contrasts and accurately reconstructs the geometry in both simulations and experiments. The TV regularized scheme reconstructs sharp spatial transitions, which are difficult to reconstruct with other, more traditional approaches. Andrea Borsic, Irina M. Perreard, Aditya Mahara, Ryan J. Halter |
IEEE Trans. Medical Imaging | 4 |
| 2016 | Prostate Cancer Detection Using Composite Impedance MetricabstractProstate cancer (PCa) recurrences are often predicted by assessing the status of surgical margins (SM)- positive surgical margins (PSM) increase the chances of biochemical recurrence by 2-4 times which may lead to PCa recurrence. To this end, an electrical impedance acquisition system with a microendoscopic probe was employed in an ex-vivo study of human prostates. This system measures the tissue bioimpedance over a range of frequencies (1 kHz to 1MHz), and computes a number of Composite Impedance Metrics (CIM). A classifier trained using CIM data can be used to classify tissue as benign or cancerous. The system was used to collect the impedance spectra from 14 excised prostates, which were obtained from men undergoing radical prostatectomy, for a total of 23 cancerous and 53 benign measurements. The data revealed statistically significant (p < 0.05) differences in the impedance properties of the benign and tumorous tissues, and among the measurements taken on the apical, base, and lateral surface of the prostate. Further, in the leave-one-patient-out cross validation, a maximum predictive accuracy of 90.79% was achieved by combining high frequency CIM phase data to train a support vector machine classifier with a radial basis function kernel. The observations are consistent with the physiology and morphology of benign and malignant prostate tissue. CIMs were found to be an effective tool in distinguishing benign from cancerous tissues. Shadab Khan, Aditya Mahara, Elias S. Hyams, Alan R. Schned, Ryan J. Halter |
IEEE Trans. Medical Imaging | 5 |
| 2015 | Real-Time Electrical Impedance Variations in Women With and Without Breast CancerabstractThe chaotic vascular network surrounding malignant tumors leads to pulsatile blood flow patterns that differ from those in benign regions of the breast. This study aimed to determine if high-speed electrical impedance tomography (EIT) is able to detect conductivity changes associated with cyclic blood-volume changes and to gauge the potential of using these signatures to differentiate malignant from benign regions within the breast. EIT imaging of pulsating latex membranes submerged in saline baths provided initial validation of its use for tracking temporally varying conductivities. Nineteen women (10 with cancer, nine without) were imaged with EIT over the course of several heartbeats in synchrony with pulse-oximetry acquisition. Eight parameters ( rs, ϕ(rt,max), rt,max, Plow:full, Phigh:full, Plow:high) relating the conductivity images and pulse-oximeter signatures were extracted and used as a means of comparing malignant and benign regions of the breast. Significant differences between malignant and benign regions of interest were noted in seven of the eight parameters. The maximum correlation between conductivity and pulse-oximeter signals, rt,max , was observed to be the optimal discriminating parameter with a receiver operating characteristic area under the curve of 0.8 and a specificity of 81% at a sensitivity of 77%. Assessing the dynamic conductivity of breast may provide additional clinical utility to that of standard imaging modalities, but further investigation is necessary to better understand the biophysical mechanisms leading to the observed conductivity changes. Ryan J. Halter, Alexander Hartov, Steven P. Poplack, Roberta M. diFlorio-Alexander, Wendy A. Wells, Kari M. Rosenkranz, Richard J. Barth, Peter A. Kaufman, Keith D. Paulsen |
IEEE Trans. Medical Imaging | 1 |
| 2015 | FPGA-Based Voltage and Current Dual Drive System for High Frame Rate Electrical Impedance TomographyabstractElectrical impedance tomography (EIT) is used to image the electrical property distribution of a tissue under test. An EIT system comprises complex hardware and software modules, which are typically designed for a specific application. Upgrading these modules is a time-consuming process, and requires rigorous testing to ensure proper functioning of new modules with the existing ones. To this end, we developed a modular and reconfigurable data acquisition (DAQ) system using National Instruments' (NI) hardware and software modules, which offer inherent compatibility over generations of hardware and software revisions. The system can be configured to use up to 32-channels. This EIT system can be used to interchangeably apply current or voltage signal, and measure the tissue response in a semi-parallel fashion. A novel signal averaging algorithm, and 512-point fast Fourier transform (FFT) computation block was implemented on the FPGA. FFT output bins were classified as signal or noise. Signal bins constitute a tissue's response to a pure or mixed tone signal. Signal bins' data can be used for traditional applications, as well as synchronous frequency-difference imaging. Noise bins were used to compute noise power on the FPGA. Noise power represents a metric of signal quality, and can be used to ensure proper tissue-electrode contact. Allocation of these computationally expensive tasks to the FPGA reduced the required bandwidth between PC, and the FPGA for high frame rate EIT. In 16-channel configuration, with a signal-averaging factor of 8, the DAQ frame rate at 100 kHz exceeded 110 frames s (-1), and signal-to-noise ratio exceeded 90 dB across the spectrum. Reciprocity error was found to be for frequencies up to 1 MHz. Static imaging experiments were performed on a high-conductivity inclusion placed in a saline filled tank; the inclusion was clearly localized in the reconstructions obtained for both absolute current and voltage mode data. Shadab Khan, Preston K. Manwaring, Andrea Borsic, Ryan J. Halter |
IEEE Trans. Medical Imaging | 4 |
| 2015 | 3D Microendoscopic Electrical Impedance Tomography for Margin Assessment During Robot-Assisted Laparoscopic ProstatectomyabstractRadially configured microendoscopic electrical impedance probes intended for intraoperative surgical margin assessment during robot-assisted laparoscopic prostatectomy (RALP) were examined through simulation, bench-top experimentation, and ex vivo tissue studies. Three probe designs with 8, 9, and 17 electrodes, respectively, were analyzed through finite element method based simulations. One mm diameter spherical inclusions ( σinclusion = 1 S/m) are positioned at various locations within a hemispherical background ( σbackground = 0.1 S/m) of radius 5 mm. An 8-electrode configuration is not able to localize the inclusion at these positions while 9 and 17-electrode configurations are able to accurately reconstruct the inclusion at maximum depth of 1 mm and 3 mm, respectively. All three probe designs were constructed and evaluated using saline phantoms and ex vivo porcine and human prostate tissues. The 17-electrode probe performed best in saline phantom studies, accurately reconstructing high contrast, 1-mm-diameter metal cylindrical inclusions in a saline bath ( σsaline = 0.1 S/m) with a position and area error of 0.46 mm and 0.84 mm2, respectively. Additionally, the 17-electrode probe was able to adequately distinguish cancerous from benign tissues in three ex vivo human prostates. Simulations, bench-top saline experiments, and ex vivo tissue sampling suggest that for intraoperative surgical margin assessment during RALP, the 17-electrode probe (as compared to an 8 and 9 electrode probe) will be necessary to provide sufficient accuracy and sensitivity. Aditya Mahara, Shadab Khan, Ethan K. Murphy, Alan R. Schned, Elias S. Hyams, Ryan J. Halter |
IEEE Trans. Medical Imaging | 6 |
| 2014 | A wearable system that knows who wears itabstractBody-area networks of pervasive wearable devices are increasingly used for health monitoring, personal assistance, entertainment, and home automation. In an ideal world, a user would simply wear their desired set of devices with no configuration necessary: the devices would discover each other, recognize that they are on the same person, construct a secure communications channel, and recognize the user to which they are attached. In this paper we address a portion of this vision by offering a wearable system that unobtrusively recognizes the person wearing it. Because it can recognize the user, our system can properly label sensor data or personalize interactions. Cory Cornelius, Ronald A. Peterson, Joseph Skinner, Ryan J. Halter, David Kotz |
MobiSys | 4 |
| 2014 | Poster: Enabling computational jewelry for mHealth applicationsabstractNo abstract available. Andres Molina-Markham, Ronald A. Peterson, Joseph Skinner, Ryan J. Halter, Jacob Sorber, David Kotz |
MobiSys | 4 |