Jana Hutter

dblp:117/1907 · also Jana Maria Hutter · DBLP profile ↗
← Back
23ranked-venue papers
5as first author
11since 2021 · last 2026
0000-0003-3476-3500ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 21 · 5 first-author · 10 since 2021Graphics, computer vision, multimedia, augmented reality and games · 10 · 3 first-author · 3 since 2021Artificial intelligence and machine learning · 1 · 1 since 2021Systems, architecture and hardware · 1 · 1 since 2021
YearPublicationVenuePosition
2026 A speech-to-video synthesis approach using spatio-temporal diffusion for vocal tract MRI
Paula Andrea Pérez-Toro, Tomás Arias-Vergara, Fangxu Xing, Xiaofeng Liu 0001, Maureen Stone 0001, Jiachen Zhuo, Juan Rafael Orozco-Arroyave, Elmar Nöth, Jana Hutter, Jerry L. Prince, Andreas K. Maier, Jonghye Woo
Medical Image Anal.9
2026 Advances in automated fetal brain MRI segmentation and biometry: Insights from the FeTA 2024 challenge
abstract
Accurate fetal brain tissue segmentation and biometric measurement are essential for monitoring neurodevelopment and detecting abnormalities in utero. The Fetal Tissue Annotation (FeTA) Challenges have established robust multi-center benchmarks for evaluating state-of-the-art segmentation methods. This paper presents the results of the 2024 challenge edition, which introduced three key innovations. First, we introduced a topology-aware metric based on the Euler characteristic difference (ED) to overcome the performance plateau observed with traditional metrics like Dice or Hausdorff distance (HD), as the performance of the best models in segmentation surpassed the inter-rater variability. While the best teams reached similar scores in Dice (0.81-0.82) and HD95 (2.1-2.3 mm), ED provided greater discriminative power: the winning method achieved an ED of 20.9, representing roughly a 50% improvement over the second- and third-ranked teams despite comparable Dice scores. Second, we introduced a new 0.55T low-field MRI test set, which, when paired with high-quality super-resolution reconstruction, achieved the highest segmentation performance across all test cohorts (Dice=0.86, HD95=1.69, ED=6.26). This provides the first quantitative evidence that low-cost, low-field MRI can match or surpass high-field systems in automated fetal brain segmentation. Third, the new biometry estimation task exposed a clear performance gap: although the best model reached a mean average percentage error (MAPE) of 7.72%, most submissions failed to outperform a simple gestational-age-based linear regression model (MAPE=9.56%), and all remained above inter-rater variability with a MAPE of 5.38%. Finally, by analyzing the top-performing models from FeTA 2024 alongside those from previous challenge editions, we identify ensembles of 3D nnU-Net trained on both real and synthetic data with both image- and anatomy-level augmentations as the most effective approaches for fetal brain segmentation. Our quantitative analysis reveals that acquisition site, super-resolution strategy, and image quality are the primary sources of domain shift, informing recommendations to enhance the robustness and generalizability of automated fetal brain analysis methods.
Vladyslav Zalevskyi, Thomas Sanchez, Misha P. T. Kaandorp, Margaux Roulet, Diego Fajardo-Rojas, Liu Li 0001, Jana Hutter, Hongwei Li 0004, Matthew J. Barkovich, Luca Wilhelmi, Aline Dändliker, Céline Steger, Mériam Koob, Yvan Gomez, Anton Jakovcic, Melita Klaic, Ana Adzic, Pavel Markovic, Gracia Grabaric, Milan Rados, Jordina Aviles Verdera, Gregor Kasprian, Gregor Dovjak, Raphael Gaubert-Rachmühl, Maurice Aschwanden, Davood Karimi, Denis Peruzzo, Tommaso Ciceri, Giorgio Longari, Rachika E. Hamadache, Amina Bouzid, Xavier Lladó, Simone Chiarella, Gerard Martí-Juan, Miguel Ángel González Ballester, Marco Castellaro, Marco Pinamonti, Valentina Visani, Robin Cremese, Keïn Sam, Fleur Gaudfernau, Param Ahir, Mehul Parikh, Maximilian Zenk, Michael Baumgartner 0001, Klaus H. Maier-Hein, Li Tianhong, Zhao Longfei, Domen Preloznik, Ziga Spiclin, Jae Won Choi, Guotai Wang, Lyuyang Tong, Bo Du 0001, Andrea Gondova, Sungmin You, Kiho Im, Abdul Qayyum 0002, Moona Mazher, Steven A. Niederer, András Jakab, Roxane Licandro, Kelly Payette, Meritxell Bach Cuadra
Medical Image Anal.7
2025 A 3D U-Net based Network for Segmenting medical images of Fetal MRI in three Dimensions
abstract
This study introduces a U-Net based algorithmic framework designed to segment 3D MRI images of perinatal fetal brains from a cohort of 20 fetuses, with gestational ages ranging from 20 to 36 weeks. Furthermore, an optimization network based on U-Net is also proposed to enhance the segmentation efficiency of the proposed U-Net framework. The experimental results indicate that the resultant Dice Score metric, Hausdorff distance and Jaccard Index all showed notable enhancements when compared to the U-Net pipeline. The final results confirm that the proposed method is highly effective for segmenting fetal brains across various gestational ages, with the optimized model yielding superior segmentation quality as compared to the conventional U-Net model.
Maneesha Singh, Sameesha Singh, Jana Hutter, L. Jiancong
IPAS3
2025 Fetal body organ T2* relaxometry at low field strength (FOREST)
abstract
Fetal Magnetic Resonance Imaging (MRI) at low field strengths is an exciting new field in both clinical and research settings. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artifacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing tools such as segmentation and reconstruction hampers wider clinical use. In this study, we present the Fetal body Organ T2* RElaxometry at low field STrength (FOREST) pipeline that analyzes ten major fetal body organs. Dynamic multi-echo multi-gradient sequences were acquired and automatically reoriented to a standard plane, reconstructed into a high-resolution volume using deformable slice-to-volume reconstruction, and then automatically segmented into ten major fetal organs. We extensively validated FOREST using an inter-rater quality analysis. We then present fetal T2* body organ growth curves made from 100 control subjects from a wide gestational age range (17-40 gestational weeks) in order to investigate the relationship of T2* with gestational age. The T2* values for all organs except the stomach and spleen were found to have a relationship with gestational age (p<0.05). FOREST is robust to fetal motion, and can be used for both normal and fetuses with pathologies. Low field fetal MRI can be used to perform advanced MRI analysis, and is a viable option for clinical scanning.
Kelly Payette, Alena Uus, Jordina Aviles Verdera, Megan Hall, Alexia Egloff, Maria Deprez, Raphaël Tomi-Tricot, Joseph V. Hajnal, Mary A. Rutherford, Lisa Story, Jana Hutter
Medical Image Anal.11
2025 HERON: High-Efficiency Real-Time Motion Quantification and Re-Acquisition for Fetal Diffusion MRI
abstract
Fetal diffusion MRI (dMRI) provides fascinating and clinically crucial insights into the microstructure of the human brain during development, but is highly sensitive to motion artifacts of fetal movement and maternal breathing, which impact data quality and limit diagnostic accuracy. This study introduces HERON, a robust, real-time, automatic pipeline designed to enhance fetal brain dMRI by performing motion assessment and re-acquisition. HERON leverages AI-driven brain localization, segmentation, and motion assessment on a clinical 0.55T scanner to automatically plan, quality check, and reacquire motion-affected dMRI volumes. Remaining inter-volume motion is corrected during post-processing. Tested in 20 cases, the pipeline effectively improved image quality, reduced intra- and inter-volume motion, and enabled more reliable quantitative analysis even in challenging cases. Excellent agreement with human observers (specificity 97%, sensitivity 92%) was shown and the mean Apparent Diffusion Coefficient and Intravoxel Incoherent Motion dropped in the majority of cases after correction. Improving fetal dMRI through an automatic AI-driven pipeline enables higher diagnostic quality and thus potentially wider use in both research and clinical applications.
Jordina Aviles Verdera, Antonia Bortolazzi, Sara Neves Silva, Kelly Payette, Kamilah St. Clair, Sarah McElroy, Shaihan J. Malik, Joseph V. Hajnal, Raphaël Tomi-Tricot, Mary A. Rutherford, Jana Hutter
IEEE Trans. Medical Imaging11
2024 Improving Cross-Domain Brain Tissue Segmentation in Fetal MRI with Synthetic Data
Vladyslav Zalevskyi, Thomas Sanchez, Margaux Roulet, Jordina Aviles Verdera, Jana Hutter, Hamza Kebiri, Meritxell Bach Cuadra
MICCAI (1)5
2024 Optimisation of quantitative brain diffusion-relaxation MRI acquisition protocols with physics-informed machine learning
abstract
Diffusion-relaxation MRI aims to extract quantitative measures that characterise microstructural tissue properties such as orientation, size, and shape, but long acquisition times are typically required. This work proposes a physics-informed learning framework to extract an optimal subset of diffusion-relaxation MRI measurements for enabling shorter acquisition times, predict non-measured signals, and estimate quantitative parameters. In vivo and synthetic brain 5D-Diffusion-T1-T2∗-weighted MRI data obtained from five healthy subjects were used for training and validation, and from a sixth participant for testing. One fully data-driven and two physics-informed machine learning methods were implemented and compared to two manual selection procedures and Cramér-Rao lower bound optimisation. The physics-informed approaches could identify measurement-subsets that yielded more consistently accurate parameter estimates in simulations than other approaches, with similar signal prediction error. Five-fold shorter protocols yielded error distributions of estimated quantitative parameters with very small effect sizes compared to estimates from the full protocol. Selected subsets commonly included a denser sampling of the shortest and longest inversion time, lowest echo time, and high b-value. The proposed framework combining machine learning and MRI physics offers a promising approach to develop shorter imaging protocols without compromising the quality of parameter estimates and signal predictions.
Álvaro Planchuelo-Gómez, Maxime Descoteaux, Hugo Larochelle, Jana Hutter, Derek K. Jones, Chantal M. W. Tax
Medical Image Anal.4
2024 A flexible generative algorithm for growing in silico placentas
abstract
The placenta is crucial for a successful pregnancy, facilitating oxygen exchange and nutrient transport between mother and fetus. Complications like fetal growth restriction and pre-eclampsia are linked to placental vascular structure abnormalities, highlighting the need for early detection of placental health issues. Computational modelling offers insights into how vascular architecture correlates with flow and oxygenation in both healthy and dysfunctional placentas. These models use synthetic networks to represent the multiscale feto-placental vasculature, but current methods lack direct control over key morphological parameters like branching angles, essential for predicting placental dysfunction. We introduce a novel generative algorithm for creating in silico placentas, allowing user-controlled customisation of feto-placental vasculatures, both as individual components (placental shape, chorionic vessels, placentone) and as a complete structure. The algorithm is physiologically underpinned, following branching laws (i.e. Murray's Law), and is defined by four key morphometric statistics: vessel diameter, vessel length, branching angle and asymmetry. Our algorithm produces structures consistent with in vivo measurements and ex vivo observations. Our sensitivity analysis highlights how vessel length variations and branching angles play a pivotal role in defining the architecture of the placental vascular network. Moreover, our approach is stochastic in nature, yielding vascular structures with different topological metrics when imposing the same input settings. Unlike previous volume-filling algorithms, our approach allows direct control over key morphological parameters, generating vascular structures that closely resemble real vascular densities and allowing for the investigation of the impact of morphological parameters on placental function in upcoming studies.
Diana C. de Oliveira, Hani Cheikh Sleiman, Kelly Payette, Jana Hutter, Lisa Story, Joseph V. Hajnal, Daniel C. Alexander, Rebecca Shipley, Paddy Slator
PLoS Comput. Biol.4
2023 An Automated Pipeline for Quantitative T2* Fetal Body MRI and Segmentation at Low Field
abstract
Fetal Magnetic Resonance Imaging at low field strengths is emerging as an exciting direction in perinatal health. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artefacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing tools such as segmentation and reconstruction hampers wider clinical use. In this study, we introduce a semi-automatic pipeline using quantitative MRI for the fetal body at low field strength resulting in fast and detailed quantitative T2* relaxometry analysis of all major fetal body organs. Multi-echo dynamic sequences of the fetal body were acquired and reconstructed into a single high-resolution volume using deformable slice-to-volume reconstruction, generating both structural and quantitative T2* 3D volumes. A neural network trained using a semi-supervised approach was created to automatically segment these fetal body 3D volumes into ten different organs (resulting in dice values > 0.74 for 8 out of 10 organs). The T2* values revealed a strong relationship with GA in the lungs, liver, and kidney parenchyma (R 2 >0.5). This pipeline was used successfully for a wide range of GAs (17–40 weeks), and is robust to motion artefacts. Low field fetal MRI can be used to perform advanced MRI analysis, and is a viable option for clinical scanning.
Kelly Payette, Alena Uus, Jordina Aviles Verdera, Carla Avena Zampieri, Megan Hall, Lisa Story, Maria Deprez, Mary A. Rutherford, Joseph V. Hajnal, Sébastien Ourselin, Raphaël Tomi-Tricot, Jana Hutter
MICCAI (7)12
2021 APPLAUSE: Automatic Prediction of PLAcental health via U-net Segmentation and statistical Evaluation
abstract
PURPOSE: Artificial-intelligence population-based automated quantification of placental maturation and health from a rapid functional Magnetic Resonance scan. The placenta plays a crucial role for any successful human pregnancy. Deviations from the normal dynamic maturation throughout gestation are closely linked to major pregnancy complications. Antenatal assessment in-vivo using T2* relaxometry has shown great promise to inform management and possible interventions but clinical translation is hampered by time consuming manual segmentation and analysis techniques based on comparison against normative curves over gestation. METHODS: This study proposes a fully automatic pipeline to predict the biological age and health of the placenta based on a free-breathing rapid (sub-30 second) T2* scan in two steps: Automatic segmentation using a U-Net and a Gaussian process regression model to characterize placental maturation and health. These are trained and evaluated on 108 3T MRI placental data sets, the evaluation included 20 high-risk pregnancies diagnosed with pre-eclampsia and/or fetal growth restriction. An independent cohort imaged at 1.5 T is used to assess the generalization of the training and evaluation pipeline. RESULTS: Across low- and high-risk groups, automatic segmentation performs worse than inter-rater performance (mean Dice coefficients of 0.58 and 0.68, respectively) but is sufficient for estimating placental mean T2* (0.986 Pearson Correlation Coefficient). The placental health prediction achieves an excellent ability to differentiate cases of placental insufficiency between 27 and 33 weeks. High abnormality scores correlate with low birth weight, premature birth and histopathological findings. Retrospective application on a different cohort imaged at 1.5 T illustrates the ability for direct clinical translation. CONCLUSION: The presented automatic pipeline facilitates a fast, robust and reliable prediction of placental maturation. It yields human-interpretable and verifiable intermediate results and quantifies uncertainties on the cohort-level and for individual predictions. The proposed machine-learning pipeline runs in close to real-time and, deployed in clinical settings, has the potential to become a cornerstone of diagnosis and intervention of placental insufficiency. APPLAUSE generalizes to an independent cohort imaged at 1.5 T, demonstrating robustness to different operational and clinical environments.
Maximilian Pietsch, Alison Ho, Alessia Bardanzellu, Aya Mutaz Ahmad Zeidan, Lucy C. Chappell, Joseph V. Hajnal, Mary A. Rutherford, Jana Hutter
Medical Image Anal.8
2021 Data-Driven multi-Contrast spectral microstructure imaging with InSpect: INtegrated SPECTral component estimation and mapping
abstract
We introduce and demonstrate an unsupervised machine learning technique for spectroscopic analysis of quantitative MRI experiments. Our algorithm supports estimation of one-dimensional spectra from single-contrast data, and multidimensional correlation spectra from simultaneous multi-contrast data. These spectrum-based approaches allow model-free investigation of tissue properties, but require regularised inversion of a Laplace transform or Fredholm integral, which is an ill-posed calculation. Here we present a method that addresses this limitation in a data-driven way. The algorithm simultaneously estimates a canonical basis of spectral components and voxelwise maps of their weightings, thereby pooling information across whole images to regularise the ill-posed problem. We show in simulations that our algorithm substantially outperforms current voxelwise spectral approaches. We demonstrate the method on multi-contrast diffusion-relaxometry placental MRI scans, revealing anatomically-relevant sub-structures, and identifying dysfunctional placentas. Our algorithm vastly reduces the data required to reliably estimate spectra, opening up the possibility of quantitative MRI spectroscopy in a wide range of new applications. Our InSpect code is available at github.com/paddyslator/inspect.
Paddy Slator, Jana Hutter, Razvan V. Marinescu, Marco Palombo, Laurence H. Jackson, Alison Ho, Lucy C. Chappell, Mary A. Rutherford, Joseph V. Hajnal, Daniel C. Alexander
Medical Image Anal.2
2020 Data-Driven Multi-contrast Spectral Microstructure Imaging with InSpect
Paddy Slator, Jana Hutter, Razvan V. Marinescu, Marco Palombo, Laurence H. Jackson, Alison Ho, Lucy C. Chappell, Mary A. Rutherford, Joseph V. Hajnal, Daniel C. Alexander
MICCAI (6)2
2020 Higher Order Spherical Harmonics Reconstruction of Fetal Diffusion MRI With Intensity Correction
abstract
We present a novel method for higher order reconstruction of fetal diffusion MRI signal that enables detection of fiber crossings. We combine data-driven motion and intensity correction with super-resolution reconstruction and spherical harmonic parametrisation to reconstruct data scattered in both spatial and angular domains into consistent fetal dMRI signal suitable for further diffusion analysis. We show that intensity correction is essential for good performance of the method and identify anatomically plausible fiber crossings. The proposed methodology has potential to facilitate detailed investigation of developing brain connectivity and microstructure in-utero.
Maria Deprez, Anthony N. Price, Daan Christiaens, Georgia Lockwood Estrin, Lucilio Cordero-Grande, Jana Hutter, Alessandro Daducci, Jacques-Donald Tournier, Mary A. Rutherford, Serena J. Counsell, Meritxell Bach Cuadra, Joseph V. Hajnal
IEEE Trans. Medical Imaging6
2019 Learning Compact ${q}$ -Space Representations for Multi-Shell Diffusion-Weighted MRI
abstract
Diffusion-weighted MRI measures the direction and scale of the local diffusion process in every voxel through its spectrum in q -space, typically acquired in one or more shells. Recent developments in microstructure imaging and multi-tissue decomposition have sparked renewed attention in the radial b -value dependence of the signal. Applications in motion correction and outlier rejection, therefore, require a compact linear signal representation that extends over the radial as well as angular domain. Here, we introduce SHARD, a data-driven representation of the q$ -space signal based on spherical harmonics and a radial decomposition into orthonormal components. This representation provides a complete, orthogonal signal basis, tailored to the spherical geometry of q -space, and calibrated to the data at hand. We demonstrate that the rank-reduced decomposition outperforms model-based alternatives in human brain data, while faithfully capturing the micro- and meso-structural information in the signal. Furthermore, we validate the potential of joint radial-spherical as compared with single-shell representations. As such, SHARD is optimally suited for applications that require low-rank signal predictions, such as motion correction and outlier rejection. Finally, we illustrate its application for the latter using outlier robust regression.
Daan Christiaens, Lucilio Cordero-Grande, Jana Hutter, Anthony N. Price, Maria Deprez, Joseph V. Hajnal, Jacques-Donald Tournier
IEEE Trans. Medical Imaging3
2018 Slice-level diffusion encoding for motion and distortion correction
abstract
Advances in microstructural modelling are leading to growing requirements on diffusion MRI acquisitions, namely sensitivity to smaller structures and better resolution of the geometric orientations. The resulting acquisitions contain highly attenuated images that present particular challenges when there is motion and geometric distortion. This study proposes to address these challenges by breaking with the conventional one-volume-one-encoding paradigm employed in conventional diffusion imaging using single-shot Echo Planar Imaging. By enabling free choice of the diffusion encoding on the slice level, a higher temporal sampling of slices with low b-value can be achieved. These allow more robust motion correction, and in combination with a second reversed phase-encoded echo, also dynamic distortion correction. These proposed advances are validated on phantom and adult experiments and employed in a study of eight foetal subjects. Equivalence in obtained diffusion quantities with the conventional method is demonstrated as well as benefits in distortion and motion correction. The resulting capability can be combined with any acquisition parameters including multiband imaging and allows application to diffusion MRI studies in general.
Jana Hutter, Daan Christiaens, Torben Schneider, Lucilio Cordero-Grande, Paddy Slator, Maria Deprez, Anthony N. Price, Jacques-Donald Tournier, Mary A. Rutherford, Joseph V. Hajnal
Medical Image Anal.1
2017 Dynamic Field Mapping and Motion Correction Using Interleaved Double Spin-Echo Diffusion MRI
Jana Hutter, Daan Christiaens, Maria Deprez, Lucilio Cordero-Grande, Paddy Slator, Anthony N. Price, Mary A. Rutherford, Joseph V. Hajnal
MICCAI (1)1
2017 Placenta Maps: In Utero Placental Health Assessment of the Human Fetus
abstract
The human placenta is essential for the supply of the fetus. To monitor the fetal development, imaging data is acquired using (US). Although it is currently the gold-standard in fetal imaging, it might not capture certain abnormalities of the placenta. (MRI) is a safe alternative for the in utero examination while acquiring the fetus data in higher detail. Nevertheless, there is currently no established procedure for assessing the condition of the placenta and consequently the fetal health. Due to maternal respiration and inherent movements of the fetus during examination, a quantitative assessment of the placenta requires fetal motion compensation, precise placenta segmentation and a standardized visualization, which are challenging tasks. Utilizing advanced motion compensation and automatic segmentation methods to extract the highly versatile shape of the placenta, we introduce a novel visualization technique that presents the fetal and maternal side of the placenta in a standardized way. Our approach enables physicians to explore the placenta even in utero. This establishes the basis for a comparative assessment of multiple placentas to analyze possible pathologic arrangements and to support the research and understanding of this vital organ. Additionally, we propose a three-dimensional structure-aware surface slicing technique in order to explore relevant regions inside the placenta. Finally, to survey the applicability of our approach, we consulted clinical experts in prenatal diagnostics and imaging. We received mainly positive feedback, especially the applicability of our technique for research purposes was appreciated.
Haichao Miao, Gabriel Mistelbauer, Alexey Karimov, Amir Alansary, Alice Davidson, David Lloyd 0003, Mellisa Damodaram, Lisa Story, Jana Hutter, Joseph V. Hajnal, Mary A. Rutherford, Bernhard Preim, Bernhard Kainz, M. Eduard Gröller
IEEE Trans. Vis. Comput. Graph.9
2015 Self-gated MRI motion modeling for respiratory motion compensation in integrated PET/MRI
Robert Grimm 0002, Sebastian Fürst, Michael Souvatzoglou, Christoph Forman, Jana Hutter, Isabel Dregely, Sibylle Ilse Ziegler, Berthold Kiefer, Joachim Hornegger, Kai Tobias Block, Stephan G. Nekolla
Medical Image Anal.5
2015 Multi-Dimensional Flow-Preserving Compressed Sensing (MuFloCoS) for Time-Resolved Velocity-Encoded Phase Contrast MRI
abstract
4-D time-resolved velocity-encoded phase-contrast MRI (4-D PCI) is a fully non-invasive technique to assess hemodynamics in vivo with a broad range of potential applications in multiple cardiovascular diseases. It is capable of providing quantitative flow values and anatomical information simultaneously. The long acquisition time, however, still inhibits its wider clinical use. Acceleration is achieved at present using parallel MRI (pMRI) techniques which can lead to substantial loss of image quality for higher acceleration factors. Both the high-dimensionality and the significant degree of spatio-temporal correlation in 4-D PCI render it ideally suited for recently proposed compressed sensing (CS) techniques. We propose the Multi-Dimensional Flow-preserving Compressed Sensing (MuFloCoS) method to exploit these properties. A multi-dimensional iterative reconstruction is combined with an interleaved sampling pattern (I-VT), an adaptive masked and weighted temporal regularization (TMW) and fully automatically obtained vessel-masks. The performance of the novel method was analyzed concerning image quality, feasibility of acceleration factors up to 15, quantitative flow values and diagnostic accuracy in phantom experiments and an in vivo carotid study with 18 volunteers. Comparison with iterative state-of-the-art methods revealed significant improvements using the new method, the temporal normalized root mean square error of the peak velocity was reduced by 45.32% for the novel MuFloCoS method with acceleration factor 9. The method was furthermore applied to two patient cases with diagnosed high-grade stenosis of the ICA, which confirmed the performance of MuFloCoS to produce valuable results in the presence of pathological findings in 56 s instead of over 8 min (full sampling).
Jana Hutter, Peter Schmitt, Marc Saake, Axel Stubinger, Robert Grimm 0002, Christoph Forman, Andreas Greiser, Joachim Hornegger, Andreas K. Maier
IEEE Trans. Medical Imaging1
2013 Free-Breathing Whole-Heart Coronary MRA: Motion Compensation Integrated into 3D Cartesian Compressed Sensing Reconstruction
Christoph Forman, Robert Grimm 0002, Jana Hutter, Andreas K. Maier, Joachim Hornegger, Michael O. Zenge
MICCAI (2)3
2013 Self-gated Radial MRI for Respiratory Motion Compensation on Hybrid PET/MR Systems
Robert Grimm 0002, Sebastian Fürst, Isabel Dregely, Christoph Forman, Jana Hutter, Sibylle Ilse Ziegler, Stephan G. Nekolla, Berthold Kiefer, Markus Schwaiger, Joachim Hornegger, Kai Tobias Block
MICCAI (3)5
2013 Low-Rank and Sparse Matrix Decomposition for Compressed Sensing Reconstruction of Magnetic Resonance 4D Phase Contrast Blood Flow Imaging (LoSDeCoS 4D-PCI)
Jana Hutter, Peter Schmitt, Gunhild E. Aandal, Andreas Greiser, Christoph Forman, Robert Grimm 0002, Joachim Hornegger, Andreas K. Maier
MICCAI (1)1
2012 Prior-Based Automatic Segmentation of the Carotid Artery Lumen in TOF MRA (PASCAL)
Jana Hutter, Hannes G. Hofmann, Robert Grimm 0002, Andreas Greiser, Marc Saake, Joachim Hornegger, Arnd Dörfler, Peter Schmitt
MICCAI (2)1