Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Stefan Gliech

dblp:117/2088 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
0since 2021 · last 2012
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Robot manipulation · 100%

Topics — the 5 heaviest of 5, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation
actuator design
0.112012
A comparison of parallel- and series elastic elements in an actuator for mimicking human ankle joint in walking and running · ICRA 2012
Robotics › Robot manipulation › wearable robotics › prosthetic device
ankle-foot prosthesis
0.112012
A comparison of parallel- and series elastic elements in an actuator for mimicking human ankle joint in walking and running · ICRA 2012
Robotics › Robot manipulation › robot design › robot mechanism design
parallel elastic actuation
0.112012
A comparison of parallel- and series elastic elements in an actuator for mimicking human ankle joint in walking and running · ICRA 2012
Robotics › Robot manipulation › wearable robotics
prosthetic device
0.112012
A comparison of parallel- and series elastic elements in an actuator for mimicking human ankle joint in walking and running · ICRA 2012
Robotics › Robot manipulation › actuator design › compliant actuator
series elastic actuator
0.112012
A comparison of parallel- and series elastic elements in an actuator for mimicking human ankle joint in walking and running · ICRA 2012

Methods — techniques the papers use, named apart from their topics

biomechanical simulation · 0.1
YearPublicationVenuePosition
2012 A comparison of parallel- and series elastic elements in an actuator for mimicking human ankle joint in walking and running
abstract
Elastic elements in prosthetic devices can help to reduce peak power (PP) and energy requirements (ER) for the actuators. Calculations showed that it is impossible with current commercial motor technology to mimic human ankle behavior in detail for higher walking and running speeds with single motor solutions using a Serial Elastic Actuator (SEA). Concerning this result we checked the requirements of a parallel elastic actuator (PEA) and a combination of serial and parallel (SE+PEA) springs. We found that a PEA can reduce PP additionally in comparison to the SEA by pre-loading the spring in the flight phase. This reduces also peak torque. But this loading needs additional energy so that the ER increase in comparison to the SEA. The SE+PEA concept can further decrease PP. With that, the ER are less than the PEA but higher than for the SEA. The results show less benefit for the PEA and the SE+PEA when a constant stiffness and a fixed parallel spring slack length is used for both gaits and all speeds. All concepts show that mimicking human ankle joint behavior in running and walking at higher speeds is still challenging for single motor devices.
Martin Grimmer 0001, Mahdy Eslamy, Stefan Gliech, André Seyfarth
ICRA3