Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Oliver Zettinig

dblp:131/3109 · DBLP profile ↗
← Back
12ranked-venue papers
4as first author
4since 2021 · last 2025
0000-0001-7344-3564ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 10 · 3 first-author · 4 since 2021Graphics, computer vision, multimedia, augmented reality and games · 7 · 2 first-author · 4 since 2021Artificial intelligence and machine learning · 2 · 1 first-authorSystems, architecture and hardware · 2 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Motion planning and robot control · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Motion planning and robot control
robot control
0.212016
Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016
Robotics › Motion planning and robot control › robot control › sensor-based control
visual servoing
0.212016
Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016
Medical and health informatics
image-guided intervention
0.212016
Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016
Medical and health informatics › computer-assisted surgery
needle insertion
0.112016
Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016

Methods — techniques the papers use, named apart from their topics

GPU-based image processing · 0.53d ultrasound registration · 0.5
YearPublicationVenuePosition
2025 Beyond Shadows: Learning Physics-Inspired Ultrasound Confidence Maps from Sparse Annotations
Matteo Ronchetti, Rüdiger Göbl, Vahit Bugra Yesilkaynak, Oliver Zettinig, Nassir Navab
MICCAI (13)4
2023 DISA: DIfferentiable Similarity Approximation for Universal Multimodal Registration
Matteo Ronchetti, Wolfgang Wein, Nassir Navab, Oliver Zettinig, Raphael Prevost
MICCAI (10)4
2022 Global Multi-modal 2D/3D Registration via Local Descriptors Learning
Viktoria Markova, Matteo Ronchetti, Wolfgang Wein, Oliver Zettinig, Raphael Prevost
MICCAI (6)4
2022 PRO-TIP: Phantom for RObust Automatic Ultrasound Calibration by TIP Detection
Matteo Ronchetti, Julia Rackerseder, Maria Tirindelli, Mehrdad Salehi, Nassir Navab, Wolfgang Wein, Oliver Zettinig
MICCAI (8)7
2020 Three-Dimensional Thyroid Assessment from Untracked 2D Ultrasound Clips
Wolfgang Wein, Mattia Lupetti, Oliver Zettinig, Simon Jagoda, Mehrdad Salehi, Viktoria Markova, Dornoosh Zonoobi, Raphael Prevost
MICCAI (3)3
2018 3D freehand ultrasound without external tracking using deep learning
Raphael Prevost, Mehrdad Salehi, Simon Jagoda, Julian Sprung, Alexander Ladikos, Oliver Zettinig, Wolfgang Wein
Medical Image Anal.8
2017 Towards MRI-Based Autonomous Robotic US Acquisitions: A First Feasibility Study
abstract
Robotic ultrasound has the potential to assist and guide physicians during interventions. In this work, we present a set of methods and a workflow to enable autonomous MRI-guided ultrasound acquisitions. Our approach uses a structured-light 3D scanner for patient-to-robot and image-to-patient calibration, which in turn is used to plan 3D ultrasound trajectories. These MRI-based trajectories are followed autonomously by the robot and are further refined online using automatic MRI/US registration. Despite the low spatial resolution of structured light scanners, the initial planned acquisition path can be followed with an accuracy of 2.46 ± 0.96 mm. This leads to a good initialization of the MRI/US registration: the 3D-scan-based alignment for planning and acquisition shows an accuracy (distance between planned ultrasound and MRI) of 4.47 mm, and 0.97 mm after an online-update of the calibration based on a closed loop registration.
Christoph Hennersperger, Bernhard Fuerst, Salvatore Virga, Oliver Zettinig, Benjamin Frisch, Thomas Neff, Nassir Navab
IEEE Trans. Medical Imaging4
2016 Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation
abstract
While intraoperative imaging is commonly used to guide surgical interventions, automatic robotic support for image-guided navigation has not yet been established in clinical routine. In this paper, we propose a novel visual servoing framework that combines, for the first time, full image-based 3D ultrasound registration with a real-time servo-control scheme. Paired with multi-modal fusion to a pre-interventional plan such as an annotated needle insertion path, it thus allows tracking a target anatomy, continuously updating the plan as the target moves, and keeping a needle guide aligned for accurate manual insertion. The presented system includes a motorized 3D ultrasound transducer mounted on a force-controlled robot and a GPU-based image processing toolkit. The tracking accuracy of our framework is validated on a geometric agar/gelatin phantom using a second robot, achieving positioning errors of on average 0.42-0.44 mm. With compounding and registration runtimes of up to total around 550 ms, real-time performance comes into reach. We also present initial results on a spine phantom, demonstrating the feasibility of our system for lumbar spine injections.
Oliver Zettinig, Bernhard Fuerst, Risto Kojcev, Mehrdad Salehi, Wolfgang Wein, Julia Rackerseder, Edoardo Sinibaldi, Benjamin Frisch, Nassir Navab
ICRA1
2016 Automatic force-compliant robotic ultrasound screening of abdominal aortic aneurysms
abstract
Ultrasound (US) imaging is commonly employed for the diagnosis and staging of abdominal aortic aneurysms (AAA), mainly due to its non-invasiveness and high availability. High inter-operator variability and a lack of repeatability of current US image acquisition impair the implementation of extensive screening programs for affected patient populations. However, this opens the way to a possible automation of the procedure, and recent works have exploited the use of robotic platforms for US applications, both in diagnostic and interventional scenarios. In this work, we propose a system for autonomous robotic US acquisitions aimed at the quantitative assessment of patients' vessel diameter for abdominal aortic aneurysm screening. Using a probabilistic measure of the US quality, we introduce an automatic estimation of the optimal pressure to be applied during the acquisition, and an online optimization of the out-of-plane rotation of the US probe to maximize the visibility of the aorta. We evaluate our method on healthy volunteers and compare the results to manual acquisitions performed by a clinical expert, demonstrating the feasibility of the presented system for AAA screening.
Salvatore Virga, Oliver Zettinig, Karin Pfister, Benjamin Frisch, Thomas Neff, Nassir Navab, Christoph Hennersperger
IROS2
2014 3D Velocity Field and Flow Profile Reconstruction from Arbitrarily Sampled Doppler Ultrasound Data
abstract
With the need for adequate analysis of blood flow dynamics, different maging modalities have been developed to measure varying blood velocities over time. Due to its numerous advantages, Doppler ultrasound sonography remains one of the most widely used techniques in clinical routine, but requires additional preprocessing to recover 3D velocity information. Despite great progress in the last years, recent approaches do not jointly consider spatial and temporal variation in blood flow. In this work, we present a novel gating- and compounding-free method to simultaneously reconstruct a 3D velocity field and a temporal flow profile from arbitrarily sampled Doppler ultrasound measurements obtained from multiple directions. Based on a laminar flow assumption, a patch-wise B-spline formulation of blood velocity is coupled for the first time with a global waveform model acting as temporal regularization. We evaluated our method on three virtual phantom datasets, demonstrating robustness in terms of noise, angle between measurements and data sparsity, and applied it successfully to five real case datasets of carotid artery examination.
Oliver Zettinig, Christoph Hennersperger, Christian Schulte zu Berge, Maximilian Baust, Nassir Navab
MICCAI (2)1
2014 Data-driven estimation of cardiac electrical diffusivity from 12-lead ECG signals
Oliver Zettinig, Tommaso Mansi, Dominik Neumann, Bogdan Georgescu, Saikiran Rapaka, Philipp Seegerer, Elham Kayvanpour, Farbod Sedaghat-Hamedani, Ali Amr, Jan Haas, Henning Steen, Hugo A. Katus, Benjamin Meder, Nassir Navab, Ali Kamen, Dorin Comaniciu
Medical Image Anal.1
2013 Fast Data-Driven Calibration of a Cardiac Electrophysiology Model from Images and ECG
Oliver Zettinig, Tommaso Mansi, Bogdan Georgescu, Elham Kayvanpour, Farbod Sedaghat-Hamedani, Ali Amr, Jan Haas, Henning Steen, Benjamin Meder, Hugo A. Katus, Nassir Navab, Ali Kamen, Dorin Comaniciu
MICCAI (1)1