Christian F. Baumgartner

dblp:131/4782 · DBLP profile ↗
← Back
24ranked-venue papers
6as first author
11since 2021 · last 2026
0000-0002-3629-4384ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 20 · 5 first-author · 10 since 2021Graphics, computer vision, multimedia, augmented reality and games · 11 · 3 first-author · 6 since 2021Artificial intelligence and machine learning · 4 · 1 first-author · 1 since 2021
YearPublicationVenuePosition
2026 A critical perspective on finite sample conformal prediction theory in medical applications
abstract
Machine learning (ML) is transforming healthcare, but safe clinical decisions demand reliable uncertainty estimates that standard ML models fail to provide. Conformal prediction (CP) is a popular tool that allows users to turn heuristic uncertainty estimates into uncertainty estimates with statistical guarantees. CP works by converting predictions of a ML model, together with a calibration sample, into prediction sets that are guaranteed to contain the true label with any desired probability. An often cited advantage is that CP theory holds for calibration samples of arbitrary size, suggesting that uncertainty estimates with practically meaningful statistical guarantees can be achieved even if only small calibration sets are available. We question this promise by showing that, although the statistical guarantees hold for calibration sets of arbitrary size, the practical utility of these guarantees does highly depend on the size of the calibration set. This observation is relevant in medical domains because data is often scarce and obtaining large calibration sets is therefore infeasible. We corroborate our critique in an empirical demonstration on a medical image classification task.
Klaus-Rudolf Kladny, Bernhard Schölkopf, Lisa M. Koch, Christian F. Baumgartner, Michael Muehlebach
Artif. Intell. Medicine4
2026 Unsupervised anomaly detection in medical imaging using aggregated normative diffusion
abstract
Early detection of anomalies in medical images such as brain magnetic resonance imaging (MRI) is highly relevant for diagnosis and treatment of many medical conditions. Supervised machine learning methods are limited to a small number of pathologies where there is good availability of labeled data. In contrast, unsupervised anomaly detection (UAD) has the potential to identify a broader spectrum of anomalies by spotting deviations from normal patterns. Our research demonstrates that previous state-of-the-art UAD approaches do not generalise well to diverse types of anomalies in multi-modal MRI data. To overcome this, we introduce a new UAD method named Aggregated Normative Diffusion (ANDi). ANDi operates by aggregating differences between predicted denoising steps and ground truth backwards transitions in Denoising Diffusion Probabilistic Models (DDPMs) that have been trained on pyramidal Gaussian noise. We validate ANDi against four recent UAD baselines, and across three diverse brain MRI datasets. We show that ANDi, in some cases, substantially surpasses these baselines and shows increased robustness to varying types of anomalies. Particularly in detecting multiple sclerosis (MS) lesions, ANDi achieves improvements of up to 44 % (0.302 to 0.436 on Lubljana, +0.134) in terms of AUPRC.
Alexander Frötscher, Jaivardhan Kapoor, Thomas Wolfers, Christian F. Baumgartner
Medical Image Anal.4
2025 Subgroup Performance Analysis in Hidden Stratifications
Alceu Bissoto, Trung-Dung Hoang, Tim Flühmann, Susu Sun, Christian F. Baumgartner, Lisa M. Koch
MICCAI (14)5
2025 Mind the Detail: Uncovering Clinically Relevant Image Details in Accelerated MRI with Semantically Diverse Reconstructions
Jan Nikolas Morshuis, Christian Schlarmann, Thomas Kustner, Christian F. Baumgartner, Matthias Hein 0001
MICCAI (2)4
2025 Prototype-Based Multiple Instance Learning for Gigapixel Whole Slide Image Classification
Susu Sun, Dominique van Midden, Geert Litjens 0001, Christian F. Baumgartner
MICCAI (14)4
2024 Subgroup-Specific Risk-Controlled Dose Estimation in Radiotherapy
Paul Fischer, Hannah Willms, Daniela Thorwarth, Michael Muehlebach, Christian F. Baumgartner
MICCAI (10)6
2024 PULPo: Probabilistic Unsupervised Laplacian Pyramid Registration
Leonard Siegert, Paul Fischer, Mattias P. Heinrich, Christian F. Baumgartner
MICCAI (2)4
2024 Editorial for the Special Issue on the 2022 Medical Imaging with Deep Learning Conference
Shadi Albarqouni, Christian F. Baumgartner, Qi Dou 0001, Ender Konukoglu, Bjoern Menze, Archana Venkataraman
Medical Image Anal.2
2023 Right for the Wrong Reason: Can Interpretable ML Techniques Detect Spurious Correlations?
Susu Sun, Lisa M. Koch, Christian F. Baumgartner
MICCAI (2)3
2022 Sampling Possible Reconstructions of Undersampled Acquisitions in MR Imaging With a Deep Learned Prior
abstract
Undersampling the k-space during MR acquisitions saves time, however results in an ill-posed inversion problem, leading to an infinite set of images as possible solutions. Traditionally, this is tackled as a reconstruction problem by searching for a single "best" image out of this solution set according to some chosen regularization or prior. This approach, however, misses the possibility of other solutions and hence ignores the uncertainty in the inversion process. In this paper, we propose a method that instead returns multiple images which are possible under the acquisition model and the chosen prior to capture the uncertainty in the inversion process. To this end, we introduce a low dimensional latent space and model the posterior distribution of the latent vectors given the acquisition data in k-space, from which we can sample in the latent space and obtain the corresponding images. We use a variational autoencoder for the latent model and the Metropolis adjusted Langevin algorithm for the sampling. We evaluate our method on two datasets; with images from the Human Connectome Project and in-house measured multi-coil images. We compare to five alternative methods. Results indicate that the proposed method produces images that match the measured k-space data better than the alternatives, while showing realistic structural variability. Furthermore, in contrast to the compared methods, the proposed method yields higher uncertainty in the undersampled phase encoding direction, as expected.
Kerem Can Tezcan, Neerav Karani, Christian F. Baumgartner, Ender Konukoglu
IEEE Trans. Medical Imaging3
2021 Semi-supervised task-driven data augmentation for medical image segmentation
abstract
Supervised learning-based segmentation methods typically require a large number of annotated training data to generalize well at test time. In medical applications, curating such datasets is not a favourable option because acquiring a large number of annotated samples from experts is time-consuming and expensive. Consequently, numerous methods have been proposed in the literature for learning with limited annotated examples. Unfortunately, the proposed approaches in the literature have not yet yielded significant gains over random data augmentation for image segmentation, where random augmentations themselves do not yield high accuracy. In this work, we propose a novel task-driven data augmentation method for learning with limited labeled data where the synthetic data generator, is optimized for the segmentation task. The generator of the proposed method models intensity and shape variations using two sets of transformations, as additive intensity transformations and deformation fields. Both transformations are optimized using labeled as well as unlabeled examples in a semi-supervised framework. Our experiments on three medical datasets, namely cardiac, prostate and pancreas, show that the proposed approach significantly outperforms standard augmentation and semi-supervised approaches for image segmentation in the limited annotation setting. The code is made publicly available at https://github.com/krishnabits001/task_driven_data_augmentation.
Krishna Chaitanya, Neerav Karani, Christian F. Baumgartner, Ertunc Erdil, Anton S. Becker, Olivio Donati, Ender Konukoglu
Medical Image Anal.3
2019 PHiSeg: Capturing Uncertainty in Medical Image Segmentation
Christian F. Baumgartner, Kerem Can Tezcan, Krishna Chaitanya, Andreas M. Hötker, Urs J. Muehlematter, Khoschy Schawkat, Anton S. Becker, Olivio Donati, Ender Konukoglu
MICCAI (2)1
2019 A Partially Reversible U-Net for Memory-Efficient Volumetric Image Segmentation
Robin Brügger, Christian F. Baumgartner, Ender Konukoglu
MICCAI (3)2
2019 MR Image Reconstruction Using Deep Density Priors
abstract
Algorithms for magnetic resonance (MR) image reconstruction from undersampled measurements exploit prior information to compensate for missing k-space data. Deep learning (DL) provides a powerful framework for extracting such information from existing image datasets, through learning, and then using it for reconstruction. Leveraging this, recent methods employed DL to learn mappings from undersampled to fully sampled images using paired datasets, including undersampled and corresponding fully sampled images, integrating prior knowledge implicitly. In this letter, we propose an alternative approach that learns the probability distribution of fully sampled MR images using unsupervised DL, specifically variational autoencoders (VAE), and use this as an explicit prior term in reconstruction, completely decoupling the encoding operation from the prior. The resulting reconstruction algorithm enjoys a powerful image prior to compensate for missing k-space data without requiring paired datasets for training nor being prone to associated sensitivities, such as deviations in undersampling patterns used in training and test time or coil settings. We evaluated the proposed method with T1 weighted images from a publicly available dataset, multi-coil complex images acquired from healthy volunteers ( N=8 ), and images with white matter lesions. The proposed algorithm, using the VAE prior, produced visually high quality reconstructions and achieved low RMSE values, outperforming most of the alternative methods on the same dataset. On multi-coil complex data, the algorithm yielded accurate magnitude and phase reconstruction results. In the experiments on images with white matter lesions, the method faithfully reconstructed the lesions.
Kerem Can Tezcan, Christian F. Baumgartner, Roger Lüchinger, Klaas P. Pruessmann, Ender Konukoglu
IEEE Trans. Medical Imaging2
2018 Visual Feature Attribution Using Wasserstein GANs
abstract
Attributing the pixels of an input image to a certain category is an important and well-studied problem in computer vision, with applications ranging from weakly supervised localisation to understanding hidden effects in the data. In recent years, approaches based on interpreting a previously trained neural network classifier have become the de facto state-of-the-art and are commonly used on medical as well as natural image datasets. In this paper, we discuss a limitation of these approaches which may lead to only a subset of the category specific features being detected. To address this problem we develop a novel feature attribution technique based on Wasserstein Generative Adversarial Networks (WGAN), which does not suffer from this limitation. We show that our proposed method performs substantially better than the state-of-the-art for visual attribution on a synthetic dataset and on real 3D neuroimaging data from patients with mild cognitive impairment (MCI) and Alzheimer's disease (AD). For AD patients the method produces compellingly realistic disease effect maps which are very close to the observed effects.
Christian F. Baumgartner, Lisa M. Koch, Kerem Can Tezcan, Jia Xi Ang, Ender Konukoglu
CVPR1
2018 A Lifelong Learning Approach to Brain MR Segmentation Across Scanners and Protocols
Neerav Karani, Krishna Chaitanya, Christian F. Baumgartner, Ender Konukoglu
MICCAI (1)3
2018 Multi-Atlas Segmentation Using Partially Annotated Data: Methods and Annotation Strategies
abstract
Multi-atlas segmentation is a widely used tool in medical image analysis, providing robust and accurate results by learning from annotated atlas datasets. However, the availability of fully annotated atlas images for training is limited due to the time required for the labelling task. Segmentation methods requiring only a proportion of each atlas image to be labelled could therefore reduce the workload on expert raters tasked with annotating atlas images. To address this issue, we first re-examine the labelling problem common in many existing approaches and formulate its solution in terms of a Markov Random Field energy minimisation problem on a graph connecting atlases and the target image. This provides a unifying framework for multi-atlas segmentation. We then show how modifications in the graph configuration of the proposed framework enable the use of partially annotated atlas images and investigate different partial annotation strategies. The proposed method was evaluated on two Magnetic Resonance Imaging (MRI) datasets for hippocampal and cardiac segmentation. Experiments were performed aimed at (1) recreating existing segmentation techniques with the proposed framework and (2) demonstrating the potential of employing sparsely annotated atlas data for multi-atlas segmentation.
Lisa M. Koch, Martin Rajchl, Wenjia Bai, Christian F. Baumgartner, Tong Tong 0001, Jonathan Passerat-Palmbach, Paul Aljabar, Daniel Rueckert
IEEE Trans. Pattern Anal. Mach. Intell.4
2018 Deep Learning Techniques for Automatic MRI Cardiac Multi-Structures Segmentation and Diagnosis: Is the Problem Solved?
abstract
Delineation of the left ventricular cavity, myocardium, and right ventricle from cardiac magnetic resonance images (multi-slice 2-D cine MRI) is a common clinical task to establish diagnosis. The automation of the corresponding tasks has thus been the subject of intense research over the past decades. In this paper, we introduce the "Automatic Cardiac Diagnosis Challenge" dataset (ACDC), the largest publicly available and fully annotated dataset for the purpose of cardiac MRI (CMR) assessment. The dataset contains data from 150 multi-equipments CMRI recordings with reference measurements and classification from two medical experts. The overarching objective of this paper is to measure how far state-of-the-art deep learning methods can go at assessing CMRI, i.e., segmenting the myocardium and the two ventricles as well as classifying pathologies. In the wake of the 2017 MICCAI-ACDC challenge, we report results from deep learning methods provided by nine research groups for the segmentation task and four groups for the classification task. Results show that the best methods faithfully reproduce the expert analysis, leading to a mean value of 0.97 correlation score for the automatic extraction of clinical indices and an accuracy of 0.96 for automatic diagnosis. These results clearly open the door to highly accurate and fully automatic analysis of cardiac CMRI. We also identify scenarios for which deep learning methods are still failing. Both the dataset and detailed results are publicly available online, while the platform will remain open for new submissions.
Olivier Bernard 0001, Alain Lalande, Clément Zotti, Frederic Cervenansky, Xin Yang 0009, Pheng-Ann Heng, Irem Cetin, Karim Lekadir, Oscar Camara 0001, Miguel Ángel González Ballester, Gerard Sanroma, Sandy Napel, Steffen E. Petersen, Georgios Tziritas, Ilias Grinias, Mahendra Khened, Alex Varghese, Ganapathy Krishnamurthi, Marc-Michel Rohé, Xavier Pennec, Maxime Sermesant, Fabian Isensee, Paul F. Jaeger, Klaus H. Maier-Hein, Peter M. Full, Ivo Wolf, Sandy Engelhardt, Christian F. Baumgartner, Lisa M. Koch, Jelmer M. Wolterink, Ivana Isgum, Yeonggul Jang, Yoonmi Hong, Jay Patravali, Shubham Jain 0006, Olivier Humbert, Pierre-Marc Jodoin
IEEE Trans. Medical Imaging28
2017 Compositional neural-network modeling of complex analog circuits
abstract
We introduce CompNN, a compositional method for the construction of a neural-network (NN) capturing the dynamic behavior of a complex analog multiple-input multiple-output (MIMO) system. CompNN first learns for each input/output pair (i, j), a small-sized nonlinear auto-regressive neural network with exogenous input (NARX) representing the transfer-function hij. The training dataset is generated by varying input i of the MIMO, only. Then, for each output j, the transfer functions hijare combined by a time-delayed neural network (TDNN) layer, fj. The training dataset for fjis generated by varying all MIMO inputs. The final output is f = (f1, ..., fn). The NNs parameters are learned using Levenberg-Marquardt back-propagation algorithm. We apply CompNN to learn an NN abstraction of a CMOS band-gap voltage-reference circuit (BGR). First, we learn the NARX NNs corresponding to trimming, load-jump and line-jump responses of the circuit. Then, we recompose the outputs by training the second layer TDNN structure. We demonstrate the performance of our learned NN in the transient simulation of the BGR by reducing the simulation-time by a factor of 17 compared to the transistor-level simulations. CompNN allows us to map particular parts of the NN to specific behavioral features of the BGR. To the best of our knowledge, CompNN is the first method to learn the NN of an analog integrated circuit (MIMO system) in a compositional fashion.
Ramin M. Hasani, Dieter Haerle, Christian F. Baumgartner, Alessio Lomuscio, Radu Grosu
IJCNN3
2017 Autoadaptive motion modelling for MR-based respiratory motion estimation
abstract
Respiratory motion poses significant challenges in image-guided interventions. In emerging treatments such as MR-guided HIFU or MR-guided radiotherapy, it may cause significant misalignments between interventional road maps obtained pre-procedure and the anatomy during the treatment, and may affect intra-procedural imaging such as MR-thermometry. Patient specific respiratory motion models provide a solution to this problem. They establish a correspondence between the patient motion and simpler surrogate data which can be acquired easily during the treatment. Patient motion can then be estimated during the treatment by acquiring only the simpler surrogate data. In the majority of classical motion modelling approaches once the correspondence between the surrogate data and the patient motion is established it cannot be changed unless the model is recalibrated. However, breathing patterns are known to significantly change in the time frame of MR-guided interventions. Thus, the classical motion modelling approach may yield inaccurate motion estimations when the relation between the motion and the surrogate data changes over the duration of the treatment and frequent recalibration may not be feasible. We propose a novel methodology for motion modelling which has the ability to automatically adapt to new breathing patterns. This is achieved by choosing the surrogate data in such a way that it can be used to estimate the current motion in 3D as well as to update the motion model. In particular, in this work, we use 2D MR slices from different slice positions to build as well as to apply the motion model. We implemented such an autoadaptive motion model by extending our previous work on manifold alignment. We demonstrate a proof-of-principle of the proposed technique on cardiac gated data of the thorax and evaluate its adaptive behaviour on realistic synthetic data containing two breathing types generated from 6 volunteers, and real data from 4 volunteers. On synthetic data the autoadaptive motion model yielded 21.45% more accurate motion estimations compared to a non-adaptive motion model 10 min after a change in breathing pattern. On real data we demonstrated the method's ability to maintain motion estimation accuracy despite a drift in the respiratory baseline. Due to the cardiac gating of the imaging data, the method is currently limited to one update per heart beat and the calibration requires approximately 12 min of scanning. Furthermore, the method has a prediction latency of 800 ms. These limitations may be overcome in future work by altering the acquisition protocol.
Christian F. Baumgartner, Christoph Kolbitsch, Jamie McClelland, Daniel Rueckert, Andrew P. King
Medical Image Anal.1
2017 SonoNet: Real-Time Detection and Localisation of Fetal Standard Scan Planes in Freehand Ultrasound
abstract
Identifying and interpreting fetal standard scan planes during 2-D ultrasound mid-pregnancy examinations are highly complex tasks, which require years of training. Apart from guiding the probe to the correct location, it can be equally difficult for a non-expert to identify relevant structures within the image. Automatic image processing can provide tools to help experienced as well as inexperienced operators with these tasks. In this paper, we propose a novel method based on convolutional neural networks, which can automatically detect 13 fetal standard views in freehand 2-D ultrasound data as well as provide a localization of the fetal structures via a bounding box. An important contribution is that the network learns to localize the target anatomy using weak supervision based on image-level labels only. The network architecture is designed to operate in real-time while providing optimal output for the localization task. We present results for real-time annotation, retrospective frame retrieval from saved videos, and localization on a very large and challenging dataset consisting of images and video recordings of full clinical anomaly screenings. We found that the proposed method achieved an average F1-score of 0.798 in a realistic classification experiment modeling real-time detection, and obtained a 90.09% accuracy for retrospective frame retrieval. Moreover, an accuracy of 77.8% was achieved on the localization task.
Christian F. Baumgartner, Konstantinos Kamnitsas, Jacqueline Matthew, Tara P. Fletcher, Sandra Smith, Lisa M. Koch, Bernhard Kainz, Daniel Rueckert
IEEE Trans. Medical Imaging1
2017 High-Resolution Self-Gated Dynamic Abdominal MRI Using Manifold Alignment
abstract
We present a novel retrospective self-gating method based on manifold alignment (MA), which enables reconstruction of free breathing, high spatial, and temporal resolution abdominal magnetic resonance imaging sequences. Based on a radial golden-angle acquisition trajectory, our method enables a multidimensional self-gating signal to be extracted from the k -space data for more accurate motion representation. The k -space radial profiles are evenly divided into a number of overlapping groups based on their radial angles. MA is then used to simultaneously learn and align the low dimensional manifolds of all groups, and embed them into a common manifold. In the manifold, k -space profiles that represent similar respiratory positions are close to each other. Image reconstruction is performed by combining radial profiles with evenly distributed angles that are close in the manifold. Our method was evaluated on both 2-D and 3-D synthetic and in vivo data sets. On the synthetic data sets, our method achieved high correlation with the ground truth in terms of image intensity and virtual navigator values. Using the in vivo data, compared with a state-of-the-art approach based on the center of k -space gating, our method was able to make use of much richer profile data for self-gating, resulting in statistically significantly better quantitative measurements in terms of organ sharpness and image gradient entropy.
Xin Chen 0003, Muhammad Usman 0014, Christian F. Baumgartner, Daniel R. Balfour, Paul K. Marsden, Andrew J. Reader, Claudia Prieto, Andrew P. King
IEEE Trans. Medical Imaging3
2016 Real-Time Standard Scan Plane Detection and Localisation in Fetal Ultrasound Using Fully Convolutional Neural Networks
Christian F. Baumgartner, Konstantinos Kamnitsas, Jacqueline Matthew, Sandra Smith, Bernhard Kainz, Daniel Rueckert
MICCAI (2)1
2014 High-resolution dynamic MR imaging of the thorax for respiratory motion correction of PET using groupwise manifold alignment
Christian F. Baumgartner, Christoph Kolbitsch, Daniel R. Balfour, Paul K. Marsden, Jamie McClelland, Daniel Rueckert, Andrew P. King
Medical Image Anal.1