Demo Data from EDBT 2026 / reviewers in the wild / expert
Benjamin Frisch
dblp:135/1630
· DBLP profile ↗
9ranked-venue papers
0as first author
0since 2021 · last 2017
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 6Graphics, computer vision, multimedia, augmented reality and games · 4Artificial intelligence and machine learning · 2Systems, architecture and hardware · 2
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
1 paper |
Motion planning and robot control · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 4 heaviest of 4, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Motion planning and robot control
robot control |
0.2 | 1 | 2016 | Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016 |
Robotics › Motion planning and robot control › robot control › sensor-based control
visual servoing |
0.2 | 1 | 2016 | Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016 |
Medical and health informatics
image-guided intervention |
0.2 | 1 | 2016 | Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016 |
Medical and health informatics › computer-assisted surgery
needle insertion |
0.1 | 1 | 2016 | Toward real-time 3D ultrasound registration-based visual servoing for interventional navigation · ICRA 2016 |
Methods — techniques the papers use, named apart from their topics
GPU-based image processing · 0.53d ultrasound registration · 0.5
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2017 | Towards MRI-Based Autonomous Robotic US Acquisitions: A First Feasibility StudyabstractRobotic ultrasound has the potential to assist and guide physicians during interventions. In this work, we present a set of methods and a workflow to enable autonomous MRI-guided ultrasound acquisitions. Our approach uses a structured-light 3D scanner for patient-to-robot and image-to-patient calibration, which in turn is used to plan 3D ultrasound trajectories. These MRI-based trajectories are followed autonomously by the robot and are further refined online using automatic MRI/US registration. Despite the low spatial resolution of structured light scanners, the initial planned acquisition path can be followed with an accuracy of 2.46 ± 0.96 mm. This leads to a good initialization of the MRI/US registration: the 3D-scan-based alignment for planning and acquisition shows an accuracy (distance between planned ultrasound and MRI) of 4.47 mm, and 0.97 mm after an online-update of the calibration based on a closed loop registration. Christoph Hennersperger, Bernhard Fuerst, Salvatore Virga, Oliver Zettinig, Benjamin Frisch, Thomas Neff, Nassir Navab |
IEEE Trans. Medical Imaging | 5 |
| 2016 | Quaternionic Upsampling: Hyperspherical Techniques for 6 DoF Pose TrackingabstractFast real-time tracking is an integral component of modern 3D computer vision pipelines. Despite their advantages in accuracy and reliability, optical trackers suffer from limited acquisition rates depending either on intrinsic sensor capabilities or physical limitations such as exposure time. Moreover, data transmission and image processing produce latency in the pose stream. We introduce quaternionic upsampling to overcome these problems. The technique models the pose parameters as points on multidimensional hyperspheres in (dual) quaternion space. In order to upsample the pose stream, we present several methods to sample points on geodesics and piecewise continuous curves on these manifolds and compare them regarding accuracy and computation efficiency. With the unified approach of quaternionic upsampling, both interpolation and extrapolation in pose space can be done by continuous linear variation of only one sampling parameter. Since the method can be implemented rather efficiently, pose rates of over 4 kHz and future pose predictions with an accuracy of 128 μm and 0.5° are possible in real-time. The method does not depend on a special tracking algorithm and can thus be used for any arbitrary 3 DoF or 6 DoF rotation or pose tracking system. Benjamin Busam, Benjamin Frisch, Nassir Navab |
3DV | 3 |
| 2016 | Toward real-time 3D ultrasound registration-based visual servoing for interventional navigationabstractWhile intraoperative imaging is commonly used to guide surgical interventions, automatic robotic support for image-guided navigation has not yet been established in clinical routine. In this paper, we propose a novel visual servoing framework that combines, for the first time, full image-based 3D ultrasound registration with a real-time servo-control scheme. Paired with multi-modal fusion to a pre-interventional plan such as an annotated needle insertion path, it thus allows tracking a target anatomy, continuously updating the plan as the target moves, and keeping a needle guide aligned for accurate manual insertion. The presented system includes a motorized 3D ultrasound transducer mounted on a force-controlled robot and a GPU-based image processing toolkit. The tracking accuracy of our framework is validated on a geometric agar/gelatin phantom using a second robot, achieving positioning errors of on average 0.42-0.44 mm. With compounding and registration runtimes of up to total around 550 ms, real-time performance comes into reach. We also present initial results on a spine phantom, demonstrating the feasibility of our system for lumbar spine injections. Oliver Zettinig, Bernhard Fuerst, Risto Kojcev, Mehrdad Salehi, Wolfgang Wein, Julia Rackerseder, Edoardo Sinibaldi, Benjamin Frisch, Nassir Navab |
ICRA | 9 |
| 2016 | Automatic force-compliant robotic ultrasound screening of abdominal aortic aneurysmsabstractUltrasound (US) imaging is commonly employed for the diagnosis and staging of abdominal aortic aneurysms (AAA), mainly due to its non-invasiveness and high availability. High inter-operator variability and a lack of repeatability of current US image acquisition impair the implementation of extensive screening programs for affected patient populations. However, this opens the way to a possible automation of the procedure, and recent works have exploited the use of robotic platforms for US applications, both in diagnostic and interventional scenarios. In this work, we propose a system for autonomous robotic US acquisitions aimed at the quantitative assessment of patients' vessel diameter for abdominal aortic aneurysm screening. Using a probabilistic measure of the US quality, we introduce an automatic estimation of the optimal pressure to be applied during the acquisition, and an online optimization of the out-of-plane rotation of the US probe to maximize the visibility of the aorta. We evaluate our method on healthy volunteers and compare the results to manual acquisitions performed by a clinical expert, demonstrating the feasibility of the presented system for AAA screening. Salvatore Virga, Oliver Zettinig, Karin Pfister, Benjamin Frisch, Thomas Neff, Nassir Navab, Christoph Hennersperger |
IROS | 5 |
| 2016 | Personalized, relevance-based Multimodal Robotic Imaging and augmented reality for Computer Assisted Interventions
Nassir Navab, Christoph Hennersperger, Benjamin Frisch, Bernhard Fuerst |
Medical Image Anal. | 3 |
| 2016 | First Robotic SPECT for Minimally Invasive Sentinel Lymph Node MappingabstractIn this paper we present the usage of a drop-in gamma probe for intra-operative Single-Photon Emission Computed Tomography (SPECT) imaging in the scope of minimally invasive robot-assisted interventions. The probe is designed to be inserted and reside inside the abdominal cavity during the intervention. It is grasped during the procedure using a robotic laparoscopic gripper enabling full six degrees of freedom handling by the surgeon. We demonstrate the first deployment of the tracked probe for intra-operative in-patient robotic SPECT enabling augmented-reality image guidance. The hybrid mechanical- and image-based in-patient probe tracking is shown to have an accuracy of 0.2 mm. The overall system performance is evaluated and tested with a phantom for gynecological sentinel lymph node interventions and compared to ground-truth data yielding a mean reconstruction accuracy of 0.67 mm. Bernhard Fuerst, Julian Sprung, Francisco Pinto, Benjamin Frisch, Thomas Wendler 0001, Hervé Simon, Laurent Mengus, Nynke S. van den Berg, Henk G. van der Poel, Fijs W. B. van Leeuwen, Nassir Navab |
IEEE Trans. Medical Imaging | 4 |
| 2015 | Cooperative Robotic Gamma Imaging: Enhancing US-guided Needle Biopsy
Benjamin Busam, Christoph Hennersperger, Julia Rackerseder, An Lu, Nassir Navab, Benjamin Frisch |
MICCAI (2) | 7 |
| 2015 | Radiopositive Tissue Displacement Compensation for SPECT-guided Surgery
Francisco Pinto, Bernhard Fuerst, Benjamin Frisch, Nassir Navab |
MICCAI (2) | 3 |
| 2014 | Towards Personalized Interventional SPECT-CT Imaging
José Gardiazabal, Philipp Matthies, Asli Okur, Jakob Vogel, Silvan Kraft, Benjamin Frisch, Tobias Lasser, Nassir Navab |
MICCAI (1) | 7 |