Demo Data from EDBT 2026 / reviewers in the wild / expert
Marco Beccani
dblp:135/8677
· DBLP profile ↗
6ranked-venue papers
1as first author
0since 2021 · last 2016
0000-0001-9728-895XORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 3 · 1 first-authorSystems, architecture and hardware · 3 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 2Computer networks · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
3 papers |
Motion planning and robot control · 52% Robot navigation and mapping · 26% Robot manipulation · 22% | |
| Computer architecture, parallel and distributed computing, and storage systems
2 papers |
Embedded and real-time systems · 100% | |
| Human-computer interaction and pervasive computing
1 paper |
Wearable and physiological sensing · 87% Accessibility and assistive technology · 13% | |
| Interdisciplinary, comprehensive, and emerging computing
2 papers |
Medical and health informatics · 100% |
Topics — the 21 heaviest of 23, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Motion planning and robot control › robot control
feedback control |
0.5 | 2 | 2016 | Jacobian-Based Iterative Method for Magnetic Localization in Robotic Capsule Endoscopy · IEEE Trans. Robotics 2016 Closed-Loop Control of Local Magnetic Actuation for Robotic Surgical Instruments · IEEE Trans. Robotics 2015 |
Robotics › Motion planning and robot control
robot control |
0.5 | 2 | 2016 | Jacobian-Based Iterative Method for Magnetic Localization in Robotic Capsule Endoscopy · IEEE Trans. Robotics 2016 Closed-Loop Control of Local Magnetic Actuation for Robotic Surgical Instruments · IEEE Trans. Robotics 2015 |
Robotics › Robot navigation and mapping
localization |
0.2 | 1 | 2016 | Jacobian-Based Iterative Method for Magnetic Localization in Robotic Capsule Endoscopy · IEEE Trans. Robotics 2016 |
Robotics › Robot navigation and mapping › localization › signal-based localization
magnetic localization |
0.2 | 1 | 2016 | Jacobian-Based Iterative Method for Magnetic Localization in Robotic Capsule Endoscopy · IEEE Trans. Robotics 2016 |
Robotics › Robot manipulation › micromanipulation
magnetic manipulation |
0.2 | 1 | 2016 | Jacobian-Based Iterative Method for Magnetic Localization in Robotic Capsule Endoscopy · IEEE Trans. Robotics 2016 |
Robotics › Motion planning and robot control › robot control
magnetic field control |
0.2 | 1 | 2015 | Closed-Loop Control of Local Magnetic Actuation for Robotic Surgical Instruments · IEEE Trans. Robotics 2015 |
Medical and health informatics › medical robotics
capsule robot |
0.2 | 1 | 2015 | Toward rapid prototyping of miniature Capsule Robots · ICRA 2015 |
Medical and health informatics
medical robotics |
0.2 | 1 | 2015 | Toward rapid prototyping of miniature Capsule Robots · ICRA 2015 |
Wearable and physiological sensing
gait analysis |
0.2 | 1 | 2015 | Design and implementation of an instrumented cane for gait recognition · ICRA 2015 |
Wearable and physiological sensing › gait analysis
gait recognition |
0.2 | 1 | 2015 | Design and implementation of an instrumented cane for gait recognition · ICRA 2015 |
Embedded and real-time systems › embedded software › embedded operating systems
TinyOS |
0.2 | 1 | 2015 | Toward rapid prototyping of miniature Capsule Robots · ICRA 2015 |
Embedded and real-time systems › embedded hardware platform
wireless embedded platform |
0.2 | 1 | 2015 | Toward rapid prototyping of miniature Capsule Robots · ICRA 2015 |
Embedded and real-time systems
cyber-physical system platforms |
0.2 | 1 | 2014 | A modular software architecture for miniature capsule robots based on TinyOS · SenSys 2014 |
Embedded and real-time systems
real-time operating systems |
0.2 | 1 | 2014 | A modular software architecture for miniature capsule robots based on TinyOS · SenSys 2014 |
Embedded and real-time systems › embedded software › embedded operating systems
sensor node operating system |
0.2 | 1 | 2014 | A modular software architecture for miniature capsule robots based on TinyOS · SenSys 2014 |
Robotics › Robot manipulation
tactile sensing |
0.2 | 1 | 2013 | Wireless tissue palpation: Proof of concept for a single degree of freedom · ICRA 2013 |
Robotics › Robot navigation and mapping
sensor fusion |
0.1 | 1 | 2016 | Jacobian-Based Iterative Method for Magnetic Localization in Robotic Capsule Endoscopy · IEEE Trans. Robotics 2016 |
Robotics › Robot manipulation › medical robotics
surgical robotics |
0.1 | 1 | 2015 | Closed-Loop Control of Local Magnetic Actuation for Robotic Surgical Instruments · IEEE Trans. Robotics 2015 |
Accessibility and assistive technology › assistive technology
assistive device |
0.1 | 1 | 2015 | Design and implementation of an instrumented cane for gait recognition · ICRA 2015 |
Embedded and real-time systems › control systems
feedback control |
0.1 | 1 | 2014 | A modular software architecture for miniature capsule robots based on TinyOS · SenSys 2014 |
Medical and health informatics › surgical robotics
minimally invasive surgery |
0.0 | 1 | 2013 | Wireless tissue palpation: Proof of concept for a single degree of freedom · ICRA 2013 |
Methods — techniques the papers use, named apart from their topics
wireless communication · 0.4modular hardware architecture · 0.4magnetic field measurement · 0.3load cell · 0.3least-squares interpolation · 0.2jacobian-based iterative method · 0.2finite element method · 0.2magnetic gear theory · 0.2gait pattern classification · 0.2embedded sensing · 0.2dynamic modeling · 0.2
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2016 | Jacobian-Based Iterative Method for Magnetic Localization in Robotic Capsule EndoscopyabstractThe purpose of this study is to validate a Jacobian-based iterative method for real-time localization of magnetically controlled endoscopic capsules. The proposed approach applies finite-element solutions to the magnetic field problem and least-squares interpolations to obtain closed-form and fast estimates of the magnetic field. By defining a closed-form expression for the Jacobian of the magnetic field relative to changes in the capsule pose, we are able to obtain an iterative localization at a faster computational time when compared with prior works, without suffering from the inaccuracies stemming from dipole assumptions. This new algorithm can be used in conjunction with an absolute localization technique that provides initialization values at a slower refresh rate. The proposed approach was assessed via simulation and experimental trials, adopting a wireless capsule equipped with a permanent magnet, six magnetic field sensors, and an inertial measurement unit. The overall refresh rate, including sensor data acquisition and wireless communication was 7 ms, thus enabling closed-loop control strategies for magnetic manipulation running faster than 100 Hz. The average localization error, expressed in cylindrical coordinates was below 7 mm in both the radial and axial components and 5$^\circ$ in the azimuthal component. The average error for the capsule orientation angles, obtained by fusing gyroscope and inclinometer measurements, was below 5$^\circ$. Christian Di Natali, Marco Beccani, Nabil Simaan, Pietro Valdastri |
IEEE Trans. Robotics | 2 |
| 2015 | Toward rapid prototyping of miniature Capsule RobotsabstractMinimally invasive robotic surgery techniques are becoming popular thanks to their enhanced patient benefits, including shorter recovery time, better cosmetic results and reduced discomforts. Less invasive procedures would be achieved with the use of Medical Capsule Robots (MCRs). These devices are characterized by low power requirements and small dimensions as well as uncompromising safety. MCRs operate wirelessly in abdominal Minimally Invasive Surgery (MIS) and Natural Orifice Transluminal Endoscopic Surgery (NOTES) or in the Gastrointestinal (GI) tract. The design process of MCRs, however, is expensive and time consuming. A platform for rapid prototyping MCRs is needed so that MCR researchers can reduce development costs and spend more time in studying innovative MCR applications. In this work, we introduce an open source modular platform geared toward rapid prototyping MCRs. To speed up the prototyping process, the MCR is programmed using TinyOS instead of bare-bone C. We present the hardware architecture of the platform, and the motivation for using TinyOS. To show the viability of TinyOS, we present results from an experiment involving sensing, actuation and wireless communication. This work lays the foundation for our future goal of building an integrated design environment for the design, analysis and simulation of MCRs. Addisu Taddese, Marco Beccani, Ekawahyu Susilo, Péter Völgyesi, Ákos Lédeczi, Pietro Valdastri |
ICRA | 2 |
| 2015 | Design and implementation of an instrumented cane for gait recognitionabstractIndependent mobility is an important aspect of an individual's life and must sometimes be augmented by use of an assistive device such as a wheeled walker or cane following a fall, injury, or functional decline. Physical therapists perform functional gait assessments to gauge the probability of an individual experiencing a fall and often recommend use of a walker, cane, or walking stick to decrease fall risk. Our team has developed a clinical assessment tool centered on a standard walking cane embedded system that can enhance a therapist's observation-based gait assessment with use of additional objective and quantitative data. This system can be utilized to detect timing and speed of cane placement, angular acceleration of the cane, and amounts of weight borne on the cane. This system is designed to assist physical therapists at the basic level in collection of objective data during gait analysis, to facilitate appropriate assistive gait device prescription, to provide patients and therapists feedback during gait training, and to reduce wrist and shoulder injuries with cane usage. However, more importantly, using the plethora of objective data that can be obtained from this cane, automated gait analysis and gait pattern classification can be performed to understand a patient's walking performance. Joshua W. Wade, Marco Beccani, Alec Myszka, Esube Bekele, Pietro Valdastri, Patricia Flemming, Michael de Riesthal, Thomas J. Withrow, Nilanjan Sarkar |
ICRA | 2 |
| 2015 | Closed-Loop Control of Local Magnetic Actuation for Robotic Surgical InstrumentsabstractWe propose local magnetic actuation (LMA) as an approach to robotic actuation for surgical instruments. An LMA actuation unit consists of a pair of diametrically magnetized single-dipole cylindrical magnets, working as magnetic gears across the abdominal wall. In this study, we developed a dynamic model for an LMA actuation unit by extending the theory proposed for coaxial magnetic gears. The dynamic model was used for closed-loop control, and two alternative strategies-using either the angular velocity at the motor or at the load as feedback parameter-were compared. The amount of mechanical power that can be transferred across the abdominal wall at different intermagnetic distances was also investigated. The proposed dynamic model presented a relative error below 7.5% in estimating the load torque from the system parameters. Both the strategies proposed for closed-loop control were effective in regulating the load speed with a relative error below 2% of the desired steady-state value. However, the load-side closed-loop control approach was more precise and allowed the system to transmit larger values of torque, showing, at the same time, less dependence from the angular velocity. In particular, an average value of 1.5 mN·m can be transferred at 7 cm, increasing up to 13.5 mN·m as the separation distance is reduced down to 2 cm. Given the constraints in diameter and volume for a surgical instrument, the proposed approach allows for transferring a larger amount of mechanical power than what would be possible to achieve by embedding commercial dc motors. Christian Di Natali, Jacopo Buzzi, Nicolo Garbin, Marco Beccani, Pietro Valdastri |
IEEE Trans. Robotics | 4 |
| 2014 | A modular software architecture for miniature capsule robots based on TinyOSabstractMinimally invasive surgical techniques are becoming popular due to their enhanced patient benefits. Less invasive procedures can be achieved with the use of wireless Medical Capsule Robots (MCRs). MCRs are low powered and small in size and can be used for physiological parameter monitoring, therapy delivery, and biopsy sampling. Designing MCRs from the ground up is a costly and time consuming process. In this work, we present a flexible modular architecture to facilitate the design of MCRs and propose using TinyOS as the operating system. To assess the architecture and validate the feasibility of TinyOS, we implement a closed-loop control of a sensor-actuator system and compare the results with a traditional MCR built based on an 8051 microcontroller (MCU) programmed in plain C. Similar performances from the two approaches lead us to conclude that TinyOS is a valid option to implement a modular architecture for designing MCRs. Addisu Taddese, Péter Völgyesi, Ákos Lédeczi, Marco Beccani, Ekawahyu Susilo, Pietro Valdastri |
SenSys | 4 |
| 2013 | Wireless tissue palpation: Proof of concept for a single degree of freedomabstractPalpating tissues and organs to identify hidden tumors or to detect buried vessels is not a viable option in laparoscopic surgery due to lack of force feedback. So far, research toward restoring tactile and kinesthetic sensations in minimally invasive surgery has focused on the distal sensing element or on the proximal rendering of haptic cues. In this work we present a pilot study to assess the feasibility of wireless tissue palpation, where a magnetic device is deployed through a standard surgical trocar and operated to perform tissue palpation without requiring a dedicated entry port. The setup consists of a wireless intra-body device and an external robotic manipulator holding a load cell and a permanent magnet. Embedded in the wireless cylindrical device (12.7 mm in diameter and 27.5 mm in height) is a sensing module, a wireless microcontroller, a battery and a permanent magnet. This preliminary study assessed the precision in reconstructing the indentation depth based on magnetic field measurements at the wireless device (i.e., 0.1 mm accuracy). Experimental trials demonstrated the effectiveness of wireless vertical indentation in detecting the elastic modulus of three different silicone tissue simulators (elastic modulus ranging from 50 kPa to 93 kPa), showing a maximum relative error below 3%. Finally, wireless palpation was used to identify differences in tissue stiffness from a lump embedded into a porcine liver. The reported results have the potential to open a new paradigm in the field of palpation devices, where direct physical connection across the abdominal wall is no longer required. Marco Beccani, Christian Di Natali, Mark Rentschler, Pietro Valdastri |
ICRA | 1 |