Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data.

Alex Beltran

dblp:136/1137 · DBLP profile ↗
← Back
3ranked-venue papers
1as first author
0since 2021 · last 2016
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Computer networks · 2 · 1 first-authorHuman-computer interaction and ubiquitous computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer networks
2 papers
Internet of things and sensor networks · 64% Network performance modeling · 36%
Human-computer interaction and pervasive computing
2 papers
Ubiquitous computing and smart environments · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Energy systems and smart grids · 100%
Computer architecture, parallel and distributed computing, and storage systems
1 paper
Energy-efficient computing · 100%

Topics — the 5 heaviest of 7, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Ubiquitous computing and smart environments › occupancy sensing
occupancy detection
0.212015
Poster: Model Predictive Control with Real-time Occupancy Detection · SenSys 2015
Network performance modeling
predictive control
0.212015
Poster: Model Predictive Control with Real-time Occupancy Detection · SenSys 2015
Internet of things and sensor networks › iot applications › smart environments
smart building
0.212015
Poster: Model Predictive Control with Real-time Occupancy Detection · SenSys 2015
Internet of things and sensor networks › wireless sensor network › distributed sensing › iot sensing
occupancy sensing
0.212013
ThermoSense: thermal array sensor networks in building management · SenSys 2013
Energy-efficient computing
building energy management
0.012013
ThermoSense: thermal array sensor networks in building management · SenSys 2013

Methods — techniques the papers use, named apart from their topics

model predictive control · 0.7thermal array sensing · 0.3user study · 0.2drifting control strategy · 0.2
YearPublicationVenuePosition
2016 FORCES: feedback and control for occupants to refine comfort and energy savings
abstract
Humans spend 90% of their lives inside buildings, but often the Heating, Ventilation, and Air Conditioning (HVAC) systems of commercial buildings do not properly maintain occupant comfort. Use of feedback through comfort voting applications has been shown to improve the quality of service, but the effects of application feedback and user interface design has not been investigated. In this work, we present several methods of feedback that use data presentation and environmental interaction in comfort voting applications. Through a 40 week user study of 61 University employees across 3 buildings, we show that feedback systems can be used to increase user satisfaction with thermal conditions from 33.9% to 93.3% and reduce energy consumption up to 18.99% compared to a system without voting. In addition, we find that by including a drifting control strategy, we find energy savings up to 37% can be realized without a significant reduction in satisfaction.
Daniel A. Winkler, Alex Beltran, Niloufar Piroozi Esfahani, Paul P. Maglio, Alberto Cerpa
UbiComp2
2015 Poster: Model Predictive Control with Real-time Occupancy Detection
abstract
Buildings are responsible for more than 40% of US primary energy consumption. Of that, nearly 50% goes to heating, ventilation and air-conditioning (HVAC) systems. Savings made in HVAC systems therefore have a major impact in energy consumption and are of critical importance. We present a model predictive control framework (MPC) for smart building control. The framework has several components, including (a) occupancy sensing in real time, (b) occupancy prediction models based on historical occupancy data, (c) thermodynamic building models, (d) weather forecasting data, and (e) a model predictive control optimization that tries to minimize monetary costs in energy use while maintaining quality comfort bounds for the building's users. We tested the system in a real building with over 40 workers, and we show that we could obtain monetary savings of more than 50% without sacrificing user comfort.
Alex Beltran, Alberto Cerpa
SenSys1
2013 ThermoSense: thermal array sensor networks in building management
abstract
Buildings are often inefficiently conditioned. Rooms that are empty are needlessly conditioned and partially filled rooms are conditioned assuming maximum occupancy. In this demonstration, we describe a system that reduces energy consumption by opportunistically reducing energy consumption based on room usage; we only condition rooms currently occupied and condition the space based on real-time occupancy measurements. We will show how a thermal sensor array can be used measure occupancy in real-time and how this occupancy information can be integrated with a real building management system in order to control the heating, cooling, ventilation and lighting of a building to optimize energy usage.
Varick L. Erickson, Alex Beltran, Daniel A. Winkler, Niloufar Piroozi Esfahani, John R. Lusby, Alberto Cerpa
SenSys2