Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Hing-Chiu Chang

dblp:138/2224 · DBLP profile ↗
← Back
5ranked-venue papers
0as first author
4since 2021 · last 2026
0000-0001-8634-328XORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 5 · 4 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Artificial intelligence
1 paper
Robot manipulation · 100%

Topics — the 1 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
computer-assisted intervention
0.612022
Shape Tracking and Feedback Control of Cardiac Catheter Using MRI-Guided Robotic Platform - Validation With Pulmonary Vein Isolation Simulator in MRI · IEEE Trans. Robotics 2022

Methods — techniques the papers use, named apart from their topics

tracking coils · 1.1learning-based modeling · 1.1fiber bragg grating sensing · 1.1
YearPublicationVenuePosition
2026 Event-Triggered Closed-Loop MPC of Positive Systems: An Enabling Technique for Robot-Assisted MRI-Guided Focused Ultrasound Hyperthermia
abstract
Magnetic resonance imaging (MRI)-guided focused ultrasound (MRg-FUS) is an effectivenoninvasiveintervention. However, when extending to mild hyperthermia treatment (mHT), accurate temperature control with uniform thermal distribution remains challenging for deep-seated targets in highly heterogeneous tissues. To this end, we propose a novel thermal modeling andclosed-loopcontrol scheme for robot-assisted MRg-FUS mHT. A discrete-time positive system is introduced for thermal dynamics modeling. By introducing an event-triggered model predictive controller, objective functions are formulated to optimize transducerphasesequences. Thermal feedback is leveraged to accommodate modeling uncertainties,closingthe control loop to generate constructive ultrasound interference. Our scheme enables simultaneous spatial and temporal heating control, maintaining target temperature within a narrow range ($41\,^\circ \mathrm{C}\text{--}43\,^\circ \mathrm{C}$). The thermal dose evaluated under unknown disturbances demonstrates the robustness of the proposed scheme against severe tissue heterogeneity. Overheating can be avoided, enhancing the potential for safe intervention. Results from mechanical transducer adjustment further support the feasibility of treating large target areas in robot-assisted mHT.
Bohao Zhu, James Lam, Hing-Chiu Chang, Iulian Iordachita, Ka-Wai Kwok
IEEE Trans. Ind. Informatics4
2025 Illuminating the unseen: Advancing MRI domain generalization through causality
Tianjiao Zeng, Furui Liu, Qi Dou 0001, Hing-Chiu Chang, Edward S. Hui
Medical Image Anal.6
2024 Omnidirectional Monolithic Marker for Intra-Operative MR-Based Positional Sensing in Closed MRI
abstract
We present a design of an inductively coupled radio frequency (ICRF) marker for magnetic resonance (MR)-based positional tracking, enabling the robust increase of tracking signal at all scanning orientations in quadrature-excited closed MR imaging (MRI). The marker employs three curved resonant circuits fully covering a cylindrical surface that encloses the signal source. Each resonant circuit is a planar spiral inductor with parallel plate capacitors fabricated monolithically on flexible printed circuit board (FPC) and bent to achieve the curved structure. Size of the constructed marker is Ø3-mm ×5 -mm with quality factor > 22, and its tracking performance was validated with 1.5 T MRI scanner. As result, the marker remains as a high positive contrast spot under 360° rotations in 3 axes. The marker can be accurately localized with a maximum error of 0.56 mm under a displacement of 56 mm from the isocenter, along with an inherent standard deviation of 0.1-mm. Accrediting to the high image contrast, the presented marker enables automatic and real-time tracking in 3D without dependency on its orientation with respect to the MRI scanner receive coil. In combination with its small form-factor, the presented marker would facilitate robust and wireless MR-based tracking for intervention and clinical diagnosis. This method targets applications that can involve rotational changes in all axes (X-Y-Z).
Chim Lee Cheung, Ge Fang, Justin D. L. Ho, Liyuan Liang, Kel Vin Tan, Fa-Hsuan Lin, Hing-Chiu Chang, Ka-Wai Kwok
IEEE Trans. Medical Imaging8
2022 Shape Tracking and Feedback Control of Cardiac Catheter Using MRI-Guided Robotic Platform - Validation With Pulmonary Vein Isolation Simulator in MRI
abstract
Cardiac electrophysiology is an effective treatment for atrial fibrillation, in which a long, steerable catheter is inserted into the heart chamber to conduct radio frequency ablation. Magnetic resonance imaging (MRI) can provide enhanced intraoperative monitoring of the ablation progress as well as the localization of catheter position. However, accurate and real-time tracking of the catheter shape and its efficient manipulation under MRI remains challenging. In this article, we designed a shape tracking system that integrates a multicore fiber Bragg grating (FBG) fiber and tracking coils with a standard cardiac catheter. Both the shape and positional tracking of the bendable section could be achieved. A learning-based modeling method is developed for cardiac catheters, which uses FBG-reconstructed three-dimensional curvatures for model initialization. The proposed modeling method was implemented on an MRI-guided robotic platform to achieve feedback control of a cardiac catheter. The shape tracking performance was experimentally verified, demonstrating 2.33° average error for each sensing segment and 1.53 mm positional accuracy at the catheter tip. The feedback control performance was tested by autonomous targeting and path following (average deviation of 0.62 mm) tasks. The overall performance of the integrated robotic system was validated by a pulmonary vein isolation simulator withex-vivotissue ablation, which employed a left atrial phantom with pulsatile liquid flow. Catheter tracking and feedback control tests were conducted in an MRI scanner, demonstrating the capability of the proposed system under MRI.
Ziyang Dong, Ge Fang, Zhuoliang He, Justin D. L. Ho, Chim Lee Cheung, Wai Lun Tang, Xiaochen Xie, Liyuan Liang, Hing-Chiu Chang, Chi Keong Ching, Ka-Wai Kwok
IEEE Trans. Robotics10
2015 Comparison of Acoustic Radiation Force Impulse Imaging Derived Carotid Plaque Stiffness With Spatially Registered MRI Determined Composition
abstract
Measurements of plaque stiffness may provide important prognostic and diagnostic information to help clinicians distinguish vulnerable plaques containing soft lipid pools from more stable, stiffer plaques. In this preliminary study, we compare in vivo ultrasonic Acoustic Radiation Force Impulse (ARFI) imaging derived measures of carotid plaque stiffness with composition determined by spatially registered Magnetic Resonance Imaging (MRI) in five human subjects with stenosis > 50%. Ultrasound imaging was implemented on a commercial diagnostic scanner with custom pulse sequences to collect spatially registered 2D longitudinal B-mode and ARFI images. A standardized, multi-contrast weighted MRI sequence was used to obtain 3D Time of Flight (TOF), T1 weighted (T1W), T2 weighted (T2W), and Proton Density Weighted (PDW) transverse image stacks of volumetric data. The MRI data was segmented to identify lipid, calcium, and normal loose matrix components using commercially available software. 3D MRI segmented plaque models were rendered and spatially registered with 2D B-mode images to create fused ultrasound and MRI volumetric images for each subject. ARFI imaging displacements in regions of interest (ROIs) derived from MRI segmented contours of varying composition were compared. Regions of calcium and normal loose matrix components identified by MRI presented as homogeneously stiff regions of similarly low (typically ≈ 1 μm) displacement in ARFI imaging. MRI identified lipid pools > 2 mm(2), found in three out of five subjects, presented as softer regions of increased displacement that were on average 1.8 times greater than the displacements in adjacent regions of loose matrix components in spatially registered ARFI images. This work provides early evidence supporting the use of ARFI imaging to noninvasively identify lipid regions in carotid artery plaques in vivo that are believed to increase the propensity of a plaque to rupture. Additionally, the results provide early training data for future studies and aid in the interpretation and possible clinical utility of ARFI imaging for identifying the elusive vulnerable plaque.
Joshua R. Doherty, Jeremy J. Dahl, Peter G. Kranz, Nada El Husseini, Hing-Chiu Chang, Nankuei Chen, Jason D. Allen, Katherine L. Ham, Gregg E. Trahey
IEEE Trans. Medical Imaging5