Bela L. Musits

dblp:139/6723 · DBLP profile ↗
← Back
3ranked-venue papers
0as first author
0since 2021 · last 1994
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 2Systems, architecture and hardware · 2Applied, interdisciplinary, general and emerging computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%
Artificial intelligence
3 papers
Robot manipulation · 100%

Topics — the 7 heaviest of 8, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
surgical robotics
0.021994
An image-directed robotic system for precise orthopaedic surgery · IEEE Trans. Robotics Autom. 1994
A surgical robot for total hip replacement surgery · ICRA 1992
Medical and health informatics
orthopedic surgery
0.011994
An image-directed robotic system for precise orthopaedic surgery · IEEE Trans. Robotics Autom. 1994
Medical and health informatics › surgical robotics
orthopedic surgical robot
0.011992
A surgical robot for total hip replacement surgery · ICRA 1992
Robotics › Robot manipulation › industrial robot
machining robot
0.021994
An image-directed robotic system for precise orthopaedic surgery · IEEE Trans. Robotics Autom. 1994
A surgical robot for total hip replacement surgery · ICRA 1992
Robotics › Robot manipulation
assembly
0.011988
Sensors for robotic assembly · ICRA 1988
Robotics › Robot manipulation
precision positioning
0.011988
Sensors for robotic assembly · ICRA 1988
Robotics › Robot manipulation › assembly
sensor-based assembly
0.011988
Sensors for robotic assembly · ICRA 1988

Methods — techniques the papers use, named apart from their topics

CT-based presurgical planning · 0.0robotic cavity preparation · 0.0tactile-vision sensing · 0.0machine vision · 0.0fiber-optic sensing · 0.0
YearPublicationVenuePosition
1994 An image-directed robotic system for precise orthopaedic surgery
abstract
The authors have developed an image-directed robotic system to augment the performance of human surgeons in precise bone machining procedures in orthopaedic surgery, initially targeted at cementless total hip replacement surgery. The total system consists of an interactive CT-based presurgical planning component and a surgical system consisting of a robot, redundant motion monitoring, and man-machine interface components. In vitro experiments conducted with this system have demonstrated an order-of-magnitude improvement in implant fit and placement accuracy, compared to standard manual preparation techniques. The first generation system described in this paper was used in a successful veterinary clinical trial on 26 dogs needing hip replacement surgery. It was the basis for subsequent development of a second-generation system that is now in human clinical trials.>
Russell H. Taylor, Brent D. Mittelstadt 0001, Howard A. Paul, William Hanson, Peter Kazanzides, Joel F. Zuhars, Bill Williamson, Bela L. Musits, Edward Glassman, William L. Bargar
IEEE Trans. Robotics Autom.8
1992 A surgical robot for total hip replacement surgery
abstract
The authors describe a robotic surgical system that has been designed to create femoral cavities that are precisely shaped and positioned for implantation of uncemented prostheses. This robotics system creates cavities with a dimensional accuracy more than 50 times greater than broached cavities, exceeds the tolerances to which implants are manufactured, and does not produce gaps that prevent bone ingrowth. A canine study was undertaken to evaluate the prosthesis fit and placement achieved by employing a surgical robot to prepare the femur. This study compared the results achieved on 15 dogs undergoing total hip replacement with manual broaching techniques and 25 dogs undergoing robotically assisted surgery. Among the 25 dogs, which ranged in age from 2/sup 1///sub 2/ to 11 years, there were no deaths, no infections, and no intraoperative complications. Human applications of this technique are also considered.>
Howard A. Paul, Brent Mittlestadt, William L. Bargar, Bela L. Musits, Russell H. Taylor, Peter Kazanzides, Joel F. Zuhars, Bill Williamson, William Hanson
ICRA4
1988 Sensors for robotic assembly
abstract
Special-purpose sensors and hybrid mechanical systems have been developed to assemble advanced electronic circuits. State-of-the-art robot systems that are used for electronic assembly and accuracy requirements for the developing surface mount technology are reviewed, showing the need for improved robot positioning capability. Examples of laboratory experiments that demonstrated successful precision assembly or testing using an ordinary robot, a micropositioner, and an optical sensing system are given. These involve fiber-optic sensing, machine-vision endpoint sensing, and hybrid tactic-vision endpoint sensing.>
Andrew E. Brennemann, Ralph L. Hollis, Mark A. Lavin, Bela L. Musits
ICRA4