EDBT 2026 Demo / reviewers in the wild / expert
Joel F. Zuhars
dblp:139/6778
· DBLP profile ↗
3ranked-venue papers
0as first author
0since 2021 · last 1994
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2Systems, architecture and hardware · 2Applied, interdisciplinary, general and emerging computing · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
3 papers |
Medical and health informatics · 100% | |
| Artificial intelligence
3 papers |
Motion planning and robot control · 54% Robot manipulation · 46% |
Topics — the 8 heaviest of 8, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics
surgical robotics |
0.0 | 3 | 1994 | An image-directed robotic system for precise orthopaedic surgery · IEEE Trans. Robotics Autom. 1994 A surgical robot for total hip replacement surgery · ICRA 1992 Force sensing and control for a surgical robot · ICRA 1992 |
Medical and health informatics
orthopedic surgery |
0.0 | 1 | 1994 | An image-directed robotic system for precise orthopaedic surgery · IEEE Trans. Robotics Autom. 1994 |
Robotics › Motion planning and robot control › robot control
force control |
0.0 | 1 | 1992 | Force sensing and control for a surgical robot · ICRA 1992 |
Robotics › Robot manipulation
force sensing |
0.0 | 1 | 1992 | Force sensing and control for a surgical robot · ICRA 1992 |
Robotics › Motion planning and robot control
robot control |
0.0 | 1 | 1992 | Force sensing and control for a surgical robot · ICRA 1992 |
Medical and health informatics › surgical robotics
orthopedic surgical robot |
0.0 | 1 | 1992 | A surgical robot for total hip replacement surgery · ICRA 1992 |
Robotics › Robot manipulation › industrial robot
machining robot |
0.0 | 2 | 1994 | An image-directed robotic system for precise orthopaedic surgery · IEEE Trans. Robotics Autom. 1994 A surgical robot for total hip replacement surgery · ICRA 1992 |
Medical and health informatics › surgical robotics
robot-assisted surgery |
0.0 | 1 | 1992 | Force sensing and control for a surgical robot · ICRA 1992 |
Methods — techniques the papers use, named apart from their topics
CT-based presurgical planning · 0.0robotic cavity preparation · 0.0guarded moves · 0.0force feedback control · 0.0ball-in-cone strategy · 0.0
| Year | Publication | Venue | Position |
|---|---|---|---|
| 1994 | An image-directed robotic system for precise orthopaedic surgeryabstractThe authors have developed an image-directed robotic system to augment the performance of human surgeons in precise bone machining procedures in orthopaedic surgery, initially targeted at cementless total hip replacement surgery. The total system consists of an interactive CT-based presurgical planning component and a surgical system consisting of a robot, redundant motion monitoring, and man-machine interface components. In vitro experiments conducted with this system have demonstrated an order-of-magnitude improvement in implant fit and placement accuracy, compared to standard manual preparation techniques. The first generation system described in this paper was used in a successful veterinary clinical trial on 26 dogs needing hip replacement surgery. It was the basis for subsequent development of a second-generation system that is now in human clinical trials.> Russell H. Taylor, Brent D. Mittelstadt 0001, Howard A. Paul, William Hanson, Peter Kazanzides, Joel F. Zuhars, Bill Williamson, Bela L. Musits, Edward Glassman, William L. Bargar |
IEEE Trans. Robotics Autom. | 6 |
| 1992 | Force sensing and control for a surgical robotabstractThe authors describe the use of force feedback in a surgical robot system (ROBODOC). The application initially being addressed is total hip replacement (THR) surgery, where the robot must prepare a cavity in the femur for an artificial implant. In this system, force feedback is used to provide safety, tactile search capabilities, and an improved man-machine interface. Output of the force sensor is monitored by a safety processor, which initiates corrective action if any of several application-defined thresholds are exceeded. The robot is able to locate objects using guarded moves and force control (ball-in-cone strategy). In addition, the force control algorithm provides an intuitive man-machine interface which allows the surgeon to guide the robot by leading its tool to the desired location. An application of force control currently under development is described, where the force feedback is used to modify the cutter feed rate (force controlled velocity).> Peter Kazanzides, Joel F. Zuhars, Brent D. Mittelstadt 0001, Russell H. Taylor |
ICRA | 2 |
| 1992 | A surgical robot for total hip replacement surgeryabstractThe authors describe a robotic surgical system that has been designed to create femoral cavities that are precisely shaped and positioned for implantation of uncemented prostheses. This robotics system creates cavities with a dimensional accuracy more than 50 times greater than broached cavities, exceeds the tolerances to which implants are manufactured, and does not produce gaps that prevent bone ingrowth. A canine study was undertaken to evaluate the prosthesis fit and placement achieved by employing a surgical robot to prepare the femur. This study compared the results achieved on 15 dogs undergoing total hip replacement with manual broaching techniques and 25 dogs undergoing robotically assisted surgery. Among the 25 dogs, which ranged in age from 2/sup 1///sub 2/ to 11 years, there were no deaths, no infections, and no intraoperative complications. Human applications of this technique are also considered.> Howard A. Paul, Brent Mittlestadt, William L. Bargar, Bela L. Musits, Russell H. Taylor, Peter Kazanzides, Joel F. Zuhars, Bill Williamson, William Hanson |
ICRA | 7 |