Jinyi Qi

dblp:14/2817 · DBLP profile ↗
← Back
35ranked-venue papers
7as first author
6since 2021 · last 2024
0000-0002-5428-0322ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 32 · 7 first-author · 6 since 2021Graphics, computer vision, multimedia, augmented reality and games · 4 · 1 since 2021
YearPublicationVenuePosition
2024 SPLIT: Statistical Positronium Lifetime Image Reconstruction via Time-Thresholding
abstract
Positron emission tomography (PET) is a widely utilized medical imaging modality that uses positron-emitting radiotracers to visualize biochemical processes in a living body. The spatiotemporal distribution of a radiotracer is estimated by detecting the coincidence photon pairs generated through positron annihilations. In human tissue, about 40% of the positrons form positroniums prior to the annihilation. The lifetime of these positroniums is influenced by the microenvironment in the tissue and could provide valuable information for better understanding of disease progression and treatment response. Currently, there are few methods available for reconstructing high-resolution lifetime images in practical applications. This paper presents an efficient statistical image reconstruction method for positronium lifetime imaging (PLI). We also analyze the random triple-coincidence events in PLI and propose a correction method for random events, which is essential for real applications. Both simulation and experimental studies demonstrate that the proposed method can produce lifetime images with high numerical accuracy, low variance, and resolution comparable to that of the activity images generated by a PET scanner with currently available time-of-flight resolution.
Bangyan Huang, Gerard Ariño-Estrada, Kamil Dulski, Roman Y. Shopa, Pawel Moskal, Ewa L. Stepien, Jinyi Qi
IEEE Trans. Medical Imaging8
2023 FLIm-Based in Vivo Classification of Residual Cancer in the Surgical Cavity During Transoral Robotic Surgery
Brent W. Weyers, Julien Bec, Jinyi Qi, Dorina Gui, Arnaud F. Bewley, Marianne Abouyared, D. Gregory Farwell, Andrew C. Birkeland, Laura Marcu
MICCAI (9)4
2023 Neural KEM: A Kernel Method With Deep Coefficient Prior for PET Image Reconstruction
abstract
Image reconstruction of low-count positron emission tomography (PET) data is challenging. Kernel methods address the challenge by incorporating image prior information in the forward model of iterative PET image reconstruction. The kernelized expectation-maximization (KEM) algorithm has been developed and demonstrated to be effective and easy to implement. A common approach for a further improvement of the kernel method would be adding an explicit regularization, which however leads to a complex optimization problem. In this paper, we propose an implicit regularization for the kernel method by using a deep coefficient prior, which represents the kernel coefficient image in the PET forward model using a convolutional neural-network. To solve the maximum-likelihood neural network-based reconstruction problem, we apply the principle of optimization transfer to derive a neural KEM algorithm. Each iteration of the algorithm consists of two separate steps: a KEM step for image update from the projection data and a deep-learning step in the image domain for updating the kernel coefficient image using the neural network. This optimization algorithm is guaranteed to monotonically increase the data likelihood. The results from computer simulations and real patient data have demonstrated that the neural KEM can outperform existing KEM and deep image prior methods.
Kuang Gong, Ramsey Derek Badawi, Edward J. Kim 0002, Jinyi Qi, Guobao Wang
IEEE Trans. Medical Imaging5
2022 Direct Reconstruction of Linear Parametric Images From Dynamic PET Using Nonlocal Deep Image Prior
abstract
Direct reconstruction methods have been developed to estimate parametric images directly from the measured PET sinograms by combining the PET imaging model and tracer kinetics in an integrated framework. Due to limited counts received, signal-to-noise-ratio (SNR) and resolution of parametric images produced by direct reconstruction frameworks are still limited. Recently supervised deep learning methods have been successfully applied to medical imaging denoising/reconstruction when large number of high-quality training labels are available. For static PET imaging, high-quality training labels can be acquired by extending the scanning time. However, this is not feasible for dynamic PET imaging, where the scanning time is already long enough. In this work, we proposed an unsupervised deep learning framework for direct parametric reconstruction from dynamic PET, which was tested on the Patlak model and the relative equilibrium Logan model. The training objective function was based on the PET statistical model. The patient’s anatomical prior image, which is readily available from PET/CT or PET/MR scans, was supplied as the network input to provide a manifold constraint, and also utilized to construct a kernel layer to perform non-local feature denoising. The linear kinetic model was embedded in the network structure as a${1} \times {1} \times {1}$convolution layer. Evaluations based on dynamic datasets of18F-FDG and11C-PiB tracers show that the proposed framework can outperform the traditional and the kernel method-based direct reconstruction methods.
Kuang Gong, Ciprian Catana, Jinyi Qi, Quanzheng Li
IEEE Trans. Medical Imaging3
2022 Deep Learning Based Joint PET Image Reconstruction and Motion Estimation
abstract
Respiratory motion is one of the main sources of motion artifacts in positron emission tomography (PET) imaging. The emission image and patient motion can be estimated simultaneously from respiratory gated data through a joint estimation framework. However, conventional motion estimation methods based on registration of a pair of images are sensitive to noise. The goal of this study is to develop a robust joint estimation method that incorporates a deep learning (DL)-based image registration approach for motion estimation. We propose a joint estimation framework by incorporating a learned image registration network into a regularized PET image reconstruction. The joint estimation was formulated as a constrained optimization problem with moving gated images related to a fixed image via the deep neural network. The constrained optimization problem is solved by the alternating direction method of multipliers (ADMM) algorithm. The effectiveness of the algorithm was demonstrated using simulated and real data. We compared the proposed DL-ADMM joint estimation algorithm with a monotonic iterative joint estimation. Motion compensated reconstructions using pre-calculated deformation fields by DL-based (DL-MC recon) and iterative (iterative-MC recon) image registration were also included for comparison. Our simulation study shows that the proposed DL-ADMM joint estimation method reduces bias compared to the ungated image without increasing noise and outperforms the competing methods. In the real data study, our proposed method also generated higher lesion contrast and sharper liver boundaries compared to the ungated image and had lower noise than the reference gated image.
Wenyuan Qi, Evren Asma, Jinyi Qi
IEEE Trans. Medical Imaging5
2022 Positronium Lifetime Image Reconstruction for TOF PET
abstract
Positron emission tomography is widely used in clinical and preclinical applications. Positronium lifetime carries information about the tissue microenvironment where positrons are emitted, but such information has not been captured because of two technical challenges. One challenge is the low sensitivity in detecting triple coincidence events. This problem has been mitigated by the recent developments of PET scanners with long (1-2 m) axial field of view. The other challenge is the low spatial resolution of the positronium lifetime images formed by existing methods that is determined by the time-of-flight (TOF) resolution (200-500 ps) of existing PET scanners. This paper solves the second challenge by developing a new image reconstruction method to generate high-resolution positronium lifetime images using existing TOF PET. Simulation studies demonstrate that the proposed method can reconstruct positronium lifetime images at much better spatial resolution than the limit set by the TOF resolution of the PET scanner. The proposed method opens up the possibility of performing positronium lifetime imaging using existing TOF PET scanners. The lifetime information can be used to understand the tissue microenvironment in vivo which could facilitate the study of disease mechanism and selection of proper treatments.
Jinyi Qi, Bangyan Huang
IEEE Trans. Medical Imaging1
2020 Machine Learning in PET: From Photon Detection to Quantitative Image Reconstruction
abstract
Machine learning has found unique applications in nuclear medicine from photon detection to quantitative image reconstruction. While there have been impressive strides in detector development for time-of-flight positron emission tomography, most detectors still make use of simple signal processing methods to extract the time and position information from the detector signals. Now with the availability of fast waveform digitizers, machine learning techniques have been applied to estimate the position and arrival time of high-energy photons. In quantitative image reconstruction, machine learning has been used to estimate various corrections factors, including scattered events and attenuation images, as well as to reduce statistical noise in reconstructed images. Here machine learning either provides a faster alternative to an existing time-consuming computation, such as in the case of scatter estimation, or creates a data-driven approach to map an implicitly defined function, such as in the case of estimating the attenuation map for PET/MR scans. In this article, we will review the abovementioned applications of machine learning in nuclear medicine.
Kuang Gong, Eric Berg, Simon R. Cherry, Jinyi Qi
Proc. IEEE4
2019 PET Image Reconstruction Using Deep Image Prior
abstract
Recently, deep neural networks have been widely and successfully applied in computer vision tasks and have attracted growing interest in medical imaging. One barrier for the application of deep neural networks to medical imaging is the need for large amounts of prior training pairs, which is not always feasible in clinical practice. This is especially true for medical image reconstruction problems, where raw data are needed. Inspired by the deep image prior framework, in this paper, we proposed a personalized network training method where no prior training pairs are needed, but only the patient's own prior information. The network is updated during the iterative reconstruction process using the patient-specific prior information and measured data. We formulated the maximum-likelihood estimation as a constrained optimization problem and solved it using the alternating direction method of multipliers algorithm. Magnetic resonance imaging guided positron emission tomography reconstruction was employed as an example to demonstrate the effectiveness of the proposed framework. Quantification results based on simulation and real data show that the proposed reconstruction framework can outperform Gaussian post-smoothing and anatomically guided reconstructions using the kernel method or the neural-network penalty.
Kuang Gong, Ciprian Catana, Jinyi Qi, Quanzheng Li
IEEE Trans. Medical Imaging3
2019 Iterative PET Image Reconstruction Using Convolutional Neural Network Representation
abstract
PET image reconstruction is challenging due to the ill-poseness of the inverse problem and limited number of detected photons. Recently, the deep neural networks have been widely and successfully used in computer vision tasks and attracted growing interests in medical imaging. In this paper, we trained a deep residual convolutional neural network to improve PET image quality by using the existing inter-patient information. An innovative feature of the proposed method is that we embed the neural network in the iterative reconstruction framework for image representation, rather than using it as a post-processing tool. We formulate the objective function as a constrained optimization problem and solve it using the alternating direction method of multipliers algorithm. Both simulation data and hybrid real data are used to evaluate the proposed method. Quantification results show that our proposed iterative neural network method can outperform the neural network denoising and conventional penalized maximum likelihood methods.
Kuang Gong, Jiahui Guan, Kyung Sang Kim, Xuezhu Zhang, Jaewon Yang, Youngho Seo, Georges El Fakhri, Jinyi Qi, Quanzheng Li
IEEE Trans. Medical Imaging8
2018 Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity
abstract
Positron emission tomography (PET) is a functional imaging modality widely used in oncology, cardiology, and neuroscience. It is highly sensitive, but suffers from relatively poor spatial resolution, as compared with anatomical imaging modalities, such as magnetic resonance imaging (MRI). With the recent development of combined PET/MR systems, we can improve the PET image quality by incorporating MR information into image reconstruction. Previously, kernel learning has been successfully embedded into static and dynamic PET image reconstruction using either PET temporal or MRI information. Here, we combine both PET temporal and MRI information adaptively to improve the quality of direct Patlak reconstruction. We examined different approaches to combine the PET and MRI information in kernel learning to address the issue of potential mismatches between MRI and PET signals. Computer simulations and hybrid real-patient data acquired on a simultaneous PET/MR scanner were used to evaluate the proposed methods. Results show that the method that combines PET temporal information and MRI spatial information adaptively based on the structure similarity index has the best performance in terms of noise reduction and resolution improvement.
Kuang Gong, Jinxiu Cheng-Liao, Guobao Wang, Kevin T. Chen, Ciprian Catana, Jinyi Qi
IEEE Trans. Medical Imaging6
2018 Corrections to "Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity"
abstract
In the above paper[1], there are typos inAlgorithm 1table. The correct version ofAlgorithm 1is given below.
Kuang Gong, Jinxiu Cheng-Liao, Guobao Wang, Kevin T. Chen, Ciprian Catana, Jinyi Qi
IEEE Trans. Medical Imaging6
2017 Sinogram Blurring Matrix Estimation From Point Sources Measurements With Rank-One Approximation for Fully 3-D PET
abstract
An accurate system matrix is essential in positron emission tomography (PET) for reconstructing high quality images. To reduce storage size and image reconstruction time, we factor the system matrix into a product of a geometry projection matrix and a sinogram blurring matrix. The geometric projection matrix is computed analytically and the sinogram blurring matrix is estimated from point source measurements. Previously, we have estimated a 2-D blurring matrix for a preclinical PET scanner. The 2-D blurring matrix only considers blurring effects within a transaxial sinogram and does not compensate for inter-sinogram blurring effects. For PET scanners with a long axial field of view, inter-sinogram blurring can be a major problem influencing the image quality in the axial direction. Hence, the estimation of a 4-D blurring matrix is desirable to further improve the image quality. The 4-D blurring matrix estimation is an ill-conditioned problem due to the large number of unknowns. Here, we propose a rank-one approximation for each blurring kernel image formed by a row vector of the sinogram blurring matrix to improve the stability of the 4-D blurring matrix estimation. The proposed method is applied to the simulated data as well as the real data obtained from an Inveon microPET scanner. The results show that the newly estimated 4-D blurring matrix can improve the image quality over those obtained with a 2-D blurring matrix and requires less point source scans to achieve similar image quality compared with an unconstrained 4-D blurring matrix estimation.
Kuang Gong, Michel Tohme, Martin Judenhofer, Yongfeng Yang, Jinyi Qi
IEEE Trans. Medical Imaging6
2017 Hybrid Pre-Log and Post-Log Image Reconstruction for Computed Tomography
abstract
Tomographic image reconstruction for low-dose computed tomography (CT) is increasingly challenging as dose continues to reduce in clinical applications. Pre-log domain methods and post-log domain methods have been proposed individually and each method has its own disadvantage. While having the potential to improve image quality for low-dose data by using an accurate imaging model, pre-log domain methods suffer slow convergence in practice due to the nonlinear transformation from the image to measurements. In contrast, post-log domain methods have fast convergence speed but the resulting image quality is suboptimal for low dose CT data because the log transformation is extremely unreliable for low-count measurements and undefined for negative values. This paper proposes a hybrid method that integrates the pre-log model and post-log model together to overcome the disadvantages of individual pre-log and post-log methods. We divide a set of CT data into high-count and low-count regions. The post-log weighted least squares model is used for measurements in the high-count region and the pre-log shifted Poisson model for measurements in the low-count region. The hybrid likelihood function can be optimized using an existing iterative algorithm. Computer simulations and phantom experiments show that the proposed hybrid method can achieve faster early convergence than the pre-log shifted Poisson likelihood method and better signal-to-noise performance than the post-log weighted least squares method.
Guobao Wang, Jinyi Qi
IEEE Trans. Medical Imaging5
2016 Improving Depth, Energy and Timing Estimation in PET Detectors with Deconvolution and Maximum Likelihood Pulse Shape Discrimination
abstract
In a scintillation detector, the light generated in the scintillator by a gamma interaction is converted to photoelectrons by a photodetector and produces a time-dependent waveform, the shape of which depends on the scintillator properties and the photodetector response. Several depth-of-interaction (DOI) encoding strategies have been developed that manipulate the scintillator's temporal response along the crystal length and therefore require pulse shape discrimination techniques to differentiate waveform shapes. In this work, we demonstrate how maximum likelihood (ML) estimation methods can be applied to pulse shape discrimination to better estimate deposited energy, DOI and interaction time (for time-of-flight (TOF) PET) of a gamma ray in a scintillation detector. We developed likelihood models based on either the estimated detection times of individual photoelectrons or the number of photoelectrons in discrete time bins, and applied to two phosphor-coated crystals (LFS and LYSO) used in a previously developed TOF-DOI detector concept. Compared with conventional analytical methods, ML pulse shape discrimination improved DOI encoding by 27% for both crystals. Using the ML DOI estimate, we were able to counter depth-dependent changes in light collection inherent to long scintillator crystals and recover the energy resolution measured with fixed depth irradiation (~11.5% for both crystals). Lastly, we demonstrated how the Richardson-Lucy algorithm, an iterative, ML-based deconvolution technique, can be applied to the digitized waveforms to deconvolve the photodetector's single photoelectron response and produce waveforms with a faster rising edge. After deconvolution and applying DOI and time-walk corrections, we demonstrated a 13% improvement in coincidence timing resolution (from 290 to 254 ps) with the LFS crystal and an 8% improvement (323 to 297 ps) with the LYSO crystal.
Eric Berg, Emilie Roncali, Will Hutchcroft, Jinyi Qi, Simon R. Cherry
IEEE Trans. Medical Imaging4
2016 Theoretical Analysis of Penalized Maximum-Likelihood Patlak Parametric Image Reconstruction in Dynamic PET for Lesion Detection
abstract
Detecting cancerous lesions is a major clinical application of emission tomography. In a previous work, we studied penalized maximum-likelihood (PML) image reconstruction for lesion detection in static PET. Here we extend our theoretical analysis of static PET reconstruction to dynamic PET. We study both the conventional indirect reconstruction and direct reconstruction for Patlak parametric image estimation. In indirect reconstruction, Patlak parametric images are generated by first reconstructing a sequence of dynamic PET images, and then performing Patlak analysis on the time activity curves (TACs) pixel-by-pixel. In direct reconstruction, Patlak parametric images are estimated directly from raw sinogram data by incorporating the Patlak model into the image reconstruction procedure. PML reconstruction is used in both the indirect and direct reconstruction methods. We use a channelized Hotelling observer (CHO) to assess lesion detectability in Patlak parametric images. Simplified expressions for evaluating the lesion detectability have been derived and applied to the selection of the regularization parameter value to maximize detection performance. The proposed method is validated using computer-based Monte Carlo simulations. Good agreements between the theoretical predictions and the Monte Carlo results are observed. Both theoretical predictions and Monte Carlo simulation results show the benefit of the indirect and direct methods under optimized regularization parameters in dynamic PET reconstruction for lesion detection, when compared with the conventional static PET reconstruction.
Guobao Wang, Jinyi Qi
IEEE Trans. Medical Imaging3
2015 Fluorescence Lifetime Imaging and Intravascular Ultrasound: Co-Registration Study Using Ex Vivo Human Coronaries
abstract
Fluorescence lifetime imaging (FLIM) has demonstrated potential for robust assessment of atherosclerotic plaques biochemical composition and for complementing conventional intravascular ultrasound (IVUS), which provides information on plaque morphology. The success of such a bi-modal imaging modality depends on accurate segmentation of the IVUS images and proper angular registration between these two modalities. This paper reports a novel IVUS segmentation methodology addressing this issue. The image preprocessing consisted of denoising, using the Wiener filter, followed by image smoothing, implemented through the application of the alternating sequential filter on the edge separability metric images. Extraction of the lumen/intima and media/adventitia boundaries was achieved by tracing the gray-scale peaks over the A-lines of the IVUS preprocessed images. Cubic spline interpolation, in both cross-sectional and longitudinal directions, ensured boundary smoothness and continuity. The detection of the guide-wire artifact in both modalities is used for angular registration. Intraluminal studies were conducted in 13 ex vivo segments of human coronaries. The IVUS segmentation accuracy was assessed against independent manual tracings, providing 91.82% sensitivity and 97.55% specificity. The proposed methodology makes the bi-modal FLIM and IVUS approach feasible for comprehensive intravascular diagnosis by providing co-registered biochemical and morphological information of atherosclerotic plaques.
Dimitris Gorpas, Hussain Fatakdawala, Julien Bec, Dinglong Ma, Diego R. Yankelevich, Jinyi Qi, Laura Marcu
IEEE Trans. Medical Imaging6
2015 PET Image Reconstruction Using Kernel Method
abstract
Image reconstruction from low-count positron emission tomography (PET) projection data is challenging because the inverse problem is ill-posed. Prior information can be used to improve image quality. Inspired by the kernel methods in machine learning, this paper proposes a kernel based method that models PET image intensity in each pixel as a function of a set of features obtained from prior information. The kernel-based image model is incorporated into the forward model of PET projection data and the coefficients can be readily estimated by the maximum likelihood (ML) or penalized likelihood image reconstruction. A kernelized expectation-maximization algorithm is presented to obtain the ML estimate. Computer simulations show that the proposed approach can achieve better bias versus variance trade-off and higher contrast recovery for dynamic PET image reconstruction than the conventional maximum likelihood method with and without post-reconstruction denoising. Compared with other regularization-based methods, the kernel method is easier to implement and provides better image quality for low-count data. Application of the proposed kernel method to a 4-D dynamic PET patient dataset showed promising results.
Guobao Wang, Jinyi Qi
IEEE Trans. Medical Imaging2
2015 Edge-Preserving PET Image Reconstruction Using Trust Optimization Transfer
abstract
Iterative image reconstruction for positron emission tomography can improve image quality by using spatial regularization. The most commonly used quadratic penalty often oversmoothes sharp edges and fine features in reconstructed images, while nonquadratic penalties can preserve edges and achieve higher contrast recovery. Existing optimization algorithms such as the expectation maximization (EM) and preconditioned conjugate gradient (PCG) algorithms work well for the quadratic penalty, but are less efficient for high-curvature or nonsmooth edge-preserving regularizations. This paper proposes a new algorithm to accelerate edge-preserving image reconstruction by using two strategies: trust surrogate and optimization transfer descent. Trust surrogate approximates the original penalty by a smoother function at each iteration, but guarantees the algorithm to descend monotonically; Optimization transfer descent accelerates a conventional optimization transfer algorithm by using conjugate gradient and line search. Results of computer simulations and real 3-D data show that the proposed algorithm converges much faster than the conventional EM and PCG for smooth edge-preserving regularization and can also be more efficient than the current state-of-art algorithms for the nonsmooth l1 regularization.
Guobao Wang, Jinyi Qi
IEEE Trans. Medical Imaging2
2012 An Optimization Transfer Algorithm for Nonlinear Parametric Image Reconstruction From Dynamic PET Data
abstract
Direct reconstruction of kinetic parameters from raw projection data is a challenging task in molecular imaging using dynamic positron emission tomography (PET). This paper presents a new optimization transfer algorithm for penalized likelihood direct reconstruction of nonlinear parametric images that is easy to use and has a fast convergence rate. Each iteration of the proposed algorithm can be implemented in three simple steps: a frame-by-frame maximum likelihood expectation-maximization (EM)-like image update, a frame-by-frame image smoothing, and a pixel-by-pixel time activity curve fitting. Computer simulation shows that the direct algorithm can achieve a better bias-variance performance than the indirect reconstruction algorithm. The convergence rate of the new algorithm is substantially faster than our previous algorithm that is based on a separable paraboloidal surrogate function. The proposed algorithm has been applied to real 4-D PET data.
Guobao Wang, Jinyi Qi
IEEE Trans. Medical Imaging2
2012 Penalized Likelihood PET Image Reconstruction Using Patch-Based Edge-Preserving Regularization
abstract
Iterative image reconstruction for positron emission tomography (PET) can improve image quality by using spatial regularization that penalizes image intensity difference between neighboring pixels. The most commonly used quadratic penalty often oversmoothes edges and fine features in reconstructed images. Nonquadratic penalties can preserve edges but often introduce piece-wise constant blocky artifacts and the results are also sensitive to the hyper-parameter that controls the shape of the penalty function. This paper presents a patch-based regularization for iterative image reconstruction that uses neighborhood patches instead of individual pixels in computing the nonquadratic penalty. The new regularization is more robust than the conventional pixel-based regularization in differentiating sharp edges from random fluctuations due to noise. An optimization transfer algorithm is developed for the penalized maximum likelihood estimation. Each iteration of the algorithm can be implemented in three simple steps: an EM-like image update, an image smoothing and a pixel-by-pixel image fusion. Computer simulations show that the proposed patch-based regularization can achieve higher contrast recovery for small objects without increasing background variation compared with the quadratic regularization. The reconstruction is also more robust to the hyper-parameter than conventional pixel-based nonquadratic regularizations. The proposed regularization method has been applied to real 3-D PET data.
Guobao Wang, Jinyi Qi
IEEE Trans. Medical Imaging2
2011 Adaptive Imaging for Lesion Detection Using a Zoom-in PET System
abstract
Positron emission tomography (PET) has become a leading modality in molecular imaging. Demands for further improvements in spatial resolution and sensitivity remain high with growing number of applications. In this paper we present a novel PET system design that integrates a high-resolution depth-of-interaction (DOI) detector into an existing PET system to obtain higher-resolution and higher-sensitivity images in a target region around the face of the high-resolution detector. A unique feature of the proposed PET system is that the high-resolution detector can be adaptively positioned based on the detectability or quantitative accuracy of a feature of interest. This paper focuses on the signal-known-exactly, background-known-exactly (SKE-BKE) detection task. We perform theoretical analysis of lesion detectability using computer observers, and then develop methods that can efficiently calculate the optimal position of the high-resolution detector that maximizes the lesion detectability. We simulated incorporation of a high-resolution DOI detector into the microPET II scanner. Quantitative results verified that the new system has better performance than the microPET II scanner in terms of spatial resolution and lesion detectability, and that the optimal position for lesion detection can be reliably predicted by the proposed method.
Jinyi Qi
IEEE Trans. Medical Imaging2
2009 Bayesian Image Reconstruction for Improving Detection Performance of Muon Tomography
abstract
Muon tomography is a novel technology that is being developed for detecting high-Z materials in vehicles or cargo containers. Maximum likelihood methods have been developed for reconstructing the scattering density image from muon measurements. However, the instability of maximum likelihood estimation often results in noisy images and low detectability of high-Z targets. In this paper, we propose using regularization to improve the image quality of muon tomography. We formulate the muon reconstruction problem in a Bayesian framework by introducing a prior distribution on scattering density images. An iterative shrinkage algorithm is derived to maximize the log posterior distribution. At each iteration, the algorithm obtains the maximum a posteriori update by shrinking an unregularized maximum likelihood update. Inverse quadratic shrinkage functions are derived for generalized Laplacian priors and inverse cubic shrinkage functions are derived for generalized Gaussian priors. Receiver operating characteristic studies using simulated data demonstrate that the Bayesian reconstruction can greatly improve the detection performance of muon tomography.
Guobao Wang, L. J. Schultz, Jinyi Qi
IEEE Trans. Image Process.3
2009 Analysis of Penalized Likelihood Image Reconstruction for Dynamic PET Quantification
abstract
Quantification of tracer kinetics using dynamic positron emission tomography (PET) provides important information for understanding the physiological and biochemical processes in humans and animals. A common procedure is to reconstruct a sequence of dynamic images first, and then apply kinetic analysis to the time activity curve of a region of interest derived from the reconstructed images. Obviously, the choice of image reconstruction method and its parameters affect the accuracy of the time activity curve and hence the estimated kinetic parameters. This paper analyzes the effects of penalized likelihood image reconstruction on tracer kinetic parameter estimation. Approximate theoretical expressions are derived to study the bias, variance, and ensemble mean squared error of the estimated kinetic parameters. Computer simulations show that these formulae predict correctly the changes of these statistics as functions of the regularization parameter. It is found that the choice of the regularization parameter has a significant impact on kinetic parameter estimation, indicating proper selection of image reconstruction parameters is important for dynamic PET. A practical method has been developed to use the theoretical formulae to guide the selection of the regularization parameter in dynamic PET image reconstruction.
Guobao Wang, Jinyi Qi
IEEE Trans. Medical Imaging2
2009 Generalized Algorithms for Direct Reconstruction of Parametric Images From Dynamic PET Data
abstract
Indirect and direct methods have been developed for reconstructing parametric images from dynamic positron emission tomography (PET) data. Indirect methods are simple and easy to implement because reconstruction and kinetic modeling are performed in two separate steps. Direct methods estimate parametric images directly from dynamic PET sinograms and, in theory, can be statistically more efficient, but the algorithms are often difficult to implement and are very specific to the kinetic model being used. This paper presents a class of generalized algorithms for direct reconstruction of parametric images that are relatively easy to implement and can be adapted to different kinetic models. The proposed algorithms use optimization transfer principle to convert the maximization of a penalized likelihood into a pixel-wise weighted least squares (WLS) kinetic fitting problem at each iteration. Thus, it can employ existing WLS algorithms developed for kinetic models. The proposed algorithms resemble the empirical iterative implementation of the indirect approach, but converge to a solution of the direct formulation. Computer simulations showed that the proposed direct reconstruction algorithms are flexible and achieve a better bias-variance tradeoff than indirect reconstruction methods.
Guobao Wang, Jinyi Qi
IEEE Trans. Medical Imaging2
2008 Statistical image reconstruction for muon tomography using Gaussian scale mixture model
abstract
Muon tomography is a novel imaging technique that uses background cosmic radiation to inspect cargo containers for detecting the transportation or smuggling of heavy nuclear materials. Empirically, muon scattering data are modeled as zero-mean Gaussian random variables with variance being a function of the atom number and density of the scattering material. However, a single Gaussian distribution cannot model the tail of the true distribution and hence results in inaccuracy in the reconstructed images. In this paper, we propose a Gaussian scale mixture (GSM) to approximate the true distribution of muon data. The GSM follows the true distribution more closely than a single Gaussian model. We have derived a maximum likelihood reconstruction algorithm using the optimization transfer principle. Receiver operating characteristics (ROC) studies were performed using computer simulated data to evaluate the new algorithm. The results show that the use of GSM improves the detection performance significantly over that of the traditional Gaussian model.
Guobao Wang, Jinyi Qi
ICIP2
2006 Theoretical study of penalized-likelihood image reconstruction for region of interest quantification
abstract
Region of interest (ROI) quantification is an important task in emission tomography (e.g., positron emission tomography and single photon emission computed tomography). It is essential for exploring clinical factors such as tumor activity, growth rate, and the efficacy of therapeutic interventions. Statistical image reconstruction methods based on the penalized maximum-likelihood (PML) or maximum a posteriori principle have been developed for emission tomography to deal with the low signal-to-noise ratio of the emission data. Similar to the filter cut-off frequency in the filtered backprojection method, the regularization parameter in PML reconstruction controls the resolution and noise tradeoff and, hence, affects ROI quantification. In this paper, we theoretically analyze the performance of ROI quantification in PML reconstructions. Building on previous work, we derive simplified theoretical expressions for the bias, variance, and ensemble mean-squared-error (EMSE) of the estimated total activity in an ROI that is surrounded by a uniform background. When the mean and covariance matrix of the activity inside the ROI are known, the theoretical expressions are readily computable and allow for fast evaluation of image quality for ROI quantification with different regularization parameters. The optimum regularization parameter can then be selected to minimize the EMSE. Computer simulations are conducted for small ROIs with variable uniform uptake. The results show that the theoretical predictions match the Monte Carlo results reasonably well.
Jinyi Qi, Ronald H. Huesman
IEEE Trans. Medical Imaging1
2004 Accurate estimation of the fisher information matrix for the PET image reconstruction problem
abstract
The Fisher information matrix (FIM) plays a key role in the analysis and applications of statistical image reconstruction methods based on Poisson data models. The elements of the FIM are a function of the reciprocal of the mean values of sinogram elements. Conventional plug-in FIM estimation methods do not work well at low counts, where the FIM estimate is highly sensitive to the reciprocal mean estimates at individual detector pairs. A generalized error look-up table (GELT) method is developed to estimate the reciprocal of the mean of the sinogram data. This approach is also extended to randoms precorrected data. Based on these techniques, an accurate FIM estimate is obtained for both Poisson and randoms precorrected data. As an application, the new GELT method is used to improve resolution uniformity and achieve near-uniform image resolution in low count situations.
Quanzheng Li, Evren Asma, Jinyi Qi, James R. Bading, Richard M. Leahy
IEEE Trans. Medical Imaging3
2004 Analysis of lesion detectability in Bayesian emission reconstruction with nonstationary object variability
abstract
Bayesian methods based on the maximum a posteriori principle (also called penalized maximum-likelihood methods) have been developed to improve image quality in emission tomography. To explore the full potential of Bayesian reconstruction for lesion detection, we derive simplified theoretical expressions that allow fast evaluation of the detectability of a lesion in Bayesian reconstruction. This work is builded on the recent progress on the theoretical analysis of image properties of statistical reconstructions and the development of numerical observers. We explicitly model the nonstationary variation of the lesion and background without assuming that they are locally stationary. The results can be used to choose the optimum prior parameters for the maximum lesion detectability. The theoretical results are validated using Monte Carlo simulations. The comparisons show good agreement between the theoretical predictions and the Monte Carlo results. We also demonstrate that the lesion detectability can be reliably estimated using one noisy data set.
Jinyi Qi
IEEE Trans. Medical Imaging1
2004 Propagation of errors from the sensitivity image in list mode reconstruction
abstract
List mode image reconstruction is attracting renewed attention. It eliminates the storage of empty sinogram bins. However, a single back projection of all LORs is still necessary for the pre-calculation of a sensitivity image. Since the detection sensitivity is dependent on the object attenuation and detector efficiency, it must be computed for each study. Exact computation of the sensitivity image can be a daunting task for modern scanners with huge numbers of LORs. Thus, some fast approximate calculation may be desirable. In this paper, we analyze the error propagation from the sensitivity image into the reconstructed image. The theoretical analysis is based on the fixed point condition of the list mode reconstruction. The nonnegativity constraint is modeled using the Kuhn-Tucker condition. With certain assumptions and the first-order Taylor series approximation, we derive a closed form expression for the error in the reconstructed image as a function of the error in the sensitivity image. The result shows that the error response is frequency-dependent and provides a simple expression for determining the required accuracy of the sensitivity image calculation. Computer simulations show that the theoretical results are in good agreement with the measured results.
Jinyi Qi, Ronald H. Huesman
IEEE Trans. Medical Imaging1
2002 Spatiotemporal reconstruction of list mode PET data
abstract
We describe a method for computing a continuous time estimate of tracer density using list-mode positron emission tomography data. The rate function in each voxel is modeled as an inhomogeneous Poisson process whose rate function can be represented using a cubic B-spline basis. The rate functions are estimated by maximizing the likelihood of the arrival times of detected photon pairs over the control vertices of the spline, modified by quadratic spatial and temporal smoothness penalties and a penalty term to enforce nonnegativity. Randoms rate functions are estimated by assuming independence between the spatial and temporal randoms distributions. Similarly, scatter rate functions are estimated by assuming spatiotemporal independence and that the temporal distribution of the scatter is proportional to the temporal distribution of the trues. A quantitative evaluation was performed using simulated data and the method is also demonstrated in a human study using 11C-raclopride.
Thomas E. Nichols, Jinyi Qi, Evren Asma, Richard M. Leahy
IEEE Trans. Medical Imaging2
2001 Theoretical Study of Lesion Detectability of MAP Reconstruction using Computer Observers
abstract
The low signal-to-noise ratio (SNR) in emission data has stimulated the development of statistical image reconstruction methods based on the maximum a posteriori (MAP) principle. Experimental examples have shown that statistical methods improve image quality compared to the conventional filtered backprojection (FBP) method. However, these results depend on isolated data sets. Here we study the lesion detectability of MAP reconstruction theoretically, using computer observers. These theoretical results can be applied to different object structures. They show that for a quadratic smoothing prior, the lesion detectability using the prewhitening observer is independent of the smoothing parameter and the neighborhood of the prior, while the nonprewhitening observer exhibits an optimum smoothing point. We also compare the results to those of FBP reconstruction. The comparison shows that for ideal positron emission tomography (PET) systems (where data are true line integrals of the tracer distribution) the MAP reconstruction has a higher SNR for lesion detection than FBP reconstruction due to the modeling of the Poisson noise. For realistic systems, MAP reconstruction further benefits from accurately modeling the physical photon detection process in PET.
Jinyi Qi, Ronald H. Huesman
IEEE Trans. Medical Imaging1
2000 Comparison of 3D maximum a posteriori and filtered backprojection algorithms for high resolution animal imaging with microPET
abstract
We have evaluated the performance of two three-dimensional (3-D) reconstruction algorithms with data acquired from microPET, a high resolution tomograph dedicated to small animal imaging. The first was a linear filtered-backprojection algorithm (FBP) with reprojection of the missing data, and the second was a statistical maximum a posteriori probability algorithm (MAP). The two algorithms were evaluated in terms of their resolution performance, both in phantoms and in vivo. Sixty independent realizations of a phantom simulating the brain of a baby monkey were acquired, each containing three million counts. Each of these realizations was reconstructed independently with both algorithms. The ensemble of the 60 reconstructed realizations was used to estimate the standard deviation as a measure of the noise for each reconstruction algorithm. More detail was recovered in the MAP reconstruction without an increase in noise relative to FBP. Studies in a simple cylindrical compartment phantom demonstrated improved recovery of known activity ratios with MAP. Finally, in vivo studies also demonstrated a clear improvement in spatial resolution using the MAP algorithm. The quantitative accuracy of the MAP reconstruction was also evaluated by comparison with autoradiography and direct well counting of tissue samples and was shown to be superior.
Arion Chatziioannou, Jinyi Qi, Alex Annala, K. Nguyen, Richard M. Leahy, Simon R. Cherry
IEEE Trans. Medical Imaging2
2000 Resolution and noise properties of MAP reconstruction for fully 3D PET
abstract
We derive approximate analytical expressions for the local impulse response and covariance of images reconstructed from fully three-dimensional (3-D) positron emission tomography (PET) data using maximum a posteriori (MAP) estimation. These expressions explicitly account for the spatially variant detector response and sensitivity of a 3-D tomograph. The resulting spatially variant impulse response and covariance are computed using 3-D Fourier transforms. A truncated Gaussian distribution is used to account for the effect on the variance of the nonnegativity constraint used in MAP reconstruction. Using Monte Carlo simulations and phantom data from the microPET small animal scanner, we show that the approximations provide reasonably accurate estimates of contrast recovery and covariance of MAP reconstruction for priors with quadratic energy functions. We also describe how these analytical results can be used to achieve near-uniform contrast recovery throughout the reconstructed volume.
Jinyi Qi, Richard M. Leahy
IEEE Trans. Medical Imaging1
1999 A theoretical study of the contrast recovery and variance of MAP reconstructions from PET data
abstract
We examine the spatial resolution and variance properties of PET images reconstructed using maximum a posteriori (MAP) or penalized-likelihood methods. Resolution is characterized by the contrast recovery coefficient (CRC) of the local impulse response. Simplified approximate expressions are derived for the local impulse response CRC's and variances for each voxel. Using these results we propose a practical scheme for selecting spatially variant smoothing parameters to optimize lesion detectability through maximization of the local CRC-to-noise ratio in the reconstructed image.
Jinyi Qi, Richard M. Leahy
IEEE Trans. Medical Imaging1
1997 Approximate maximum likelihood hyperparameter estimation for Gibbs priors
abstract
The parameters of the prior, the hyperparameters, play an important role in Bayesian image estimation. Of particular importance for the case of Gibbs priors is the global hyperparameter, beta, which multiplies the Hamiltonian. Here we consider maximum likelihood (ML) estimation of beta from incomplete data, i.e., problems in which the image, which is drawn from a Gibbs prior, is observed indirectly through some degradation or blurring process. Important applications include image restoration and image reconstruction from projections. Exact ML estimation of beta from incomplete data is intractable for most image processing. Here we present an approximate ML estimator that is computed simultaneously with a maximum a posteriori (MAP) image estimate. The algorithm is based on a mean field approximation technique through which multidimensional Gibbs distributions are approximated by a separable function equal to a product of one-dimensional (1-D) densities. We show how this approach can be used to simplify the ML estimation problem. We also show how the Gibbs-Bogoliubov-Feynman (GBF) bound can be used to optimize the approximation for a restricted class of problems. We present the results of a Monte Carlo study that examines the bias and variance of this estimator when applied to image restoration.
Richard M. Leahy, Jinyi Qi
IEEE Trans. Image Process.3