Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Yasuyuki Shiraishi

dblp:15/9966 · DBLP profile ↗
← Back
2ranked-venue papers
0as first author
0since 2021 · last 2012
0000-0002-5036-3593ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 2Systems, architecture and hardware · 2

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
2 papers
Robot manipulation · 100%
Interdisciplinary, comprehensive, and emerging computing
2 papers
Medical and health informatics · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › medical robotics
needle insertion
0.322012
Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment · ICRA 2012
In vitro and in vivo validation of robotic palpation-based needle insertion method for breast tumor treatment · ICRA 2011
Medical and health informatics › oncology
breast tumor treatment
0.122012
Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment · ICRA 2012
In vitro and in vivo validation of robotic palpation-based needle insertion method for breast tumor treatment · ICRA 2011

Methods — techniques the papers use, named apart from their topics

numerical simulation · 0.3in vitro and in vivo experiments · 0.3ultrasound imaging · 0.2in vitro and in vivo validation · 0.2
YearPublicationVenuePosition
2012 Geometry effect of preloading probe on accurate needle insertion for breast tumor treatment
abstract
We herein describe a needle insertion method involving tissue preloading for accurate breast tumor treatment. A mechanical preloading probe locates a tumor lesion from ultrasound imaging information and reduces lesion displacement during needle insertion by pressing the breast tissue. We validated the insertion accuracy of this method by numerical simulation and experiments both in vitro and in vivo. For further accuracy enhancement, we evaluated the geometry effect of the preloading probe on needle insertion accuracy by experiments in vitro. We compared the insertion accuracy between insertion with preloading using different probe diameters and normal needle insertion. In addition, we compared insertion accuracy at different tumor depths. The data indicated a tendency for adaptation of larger preloading probe diameters with deeper tumors. This suggests the potential for our method to enhance placement accuracy by real-time geometry regulation.
Maya Hatano, Yo Kobayashi, Makiko Suzuki, Yasuyuki Shiraishi, Tomoyuki Yambe, Makoto Hashizume, Masakatsu G. Fujie
ICRA4
2011 In vitro and in vivo validation of robotic palpation-based needle insertion method for breast tumor treatment
abstract
We describe a palpation-based needle insertion method for diagnostic biopsy and radiofrequency ablation treatment of a breast tumor. The mechanical palpation probe locates cancerous tissue from ultrasound imaging information and reduces tissue displacement during needle insertion by pressing the breast tissue. We examined the insertion accuracy of this method and compared palpation-based needle insertion with normal needle insertion both in vitro and in vivo. Palpation-based needle insertion had a smaller error, suggesting that this procedure is a safe, effective alternative to traditional methods of breast needle insertion.
Maya Hatano, Yo Kobayashi, Ryutaro Hamano, Makiko Suzuki, Yasuyuki Shiraishi, Tomoyuki Yambe, Kozo Konishi, Makoto Hashizume, Masakatsu G. Fujie
ICRA5