Demo Data from EDBT 2026 / reviewers in the wild / expert
Gregory J. Mancini
dblp:151/9319
· DBLP profile ↗
7ranked-venue papers
0as first author
2since 2021 · last 2024
0000-0002-2319-2098ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 7 · 2 since 2021Systems, architecture and hardware · 7 · 2 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
3 papers |
Robot manipulation · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
5 papers |
Medical and health informatics · 100% | |
| Human-computer interaction and pervasive computing
1 paper |
Haptics and multimodal interaction · 100% |
Topics — the 13 heaviest of 13, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation › medical robotics
surgical robotics |
1.1 | 2 | 2024 | Towards a Novel Soft Magnetic Laparoscope for Single Incision Laparoscopic Surgery · ICRA 2024 A Noninvasive Approach to Recovering the Lost Force Feedback for a Robotic-Assisted Insertable Laparoscopic Surgical Camera · ICRA 2019 |
Robotics › Robot manipulation
laparoscopic surgery |
0.8 | 1 | 2024 | Towards a Novel Soft Magnetic Laparoscope for Single Incision Laparoscopic Surgery · ICRA 2024 |
Medical and health informatics
surgical robotics |
0.6 | 2 | 2021 | Recovering Stress Distribution on Deformable Tissue for a Magnetic Actuated Insertable Laparoscopic Surgical Camera · ICRA 2021 Design of a unified active locomotion mechanism for a capsule-shaped laparoscopic camera system · ICRA 2014 |
Medical and health informatics › surgical robotics
minimally invasive surgery |
0.5 | 1 | 2021 | Recovering Stress Distribution on Deformable Tissue for a Magnetic Actuated Insertable Laparoscopic Surgical Camera · ICRA 2021 |
Robotics › Robot manipulation › actuation
magnetic actuation |
0.4 | 1 | 2019 | A Noninvasive Approach to Recovering the Lost Force Feedback for a Robotic-Assisted Insertable Laparoscopic Surgical Camera · ICRA 2019 |
Medical and health informatics
computer-assisted surgery |
0.4 | 1 | 2019 | A Noninvasive Approach to Recovering the Lost Force Feedback for a Robotic-Assisted Insertable Laparoscopic Surgical Camera · ICRA 2019 |
Medical and health informatics › surgical robotics › minimally invasive surgery
laparoscopic surgery |
0.4 | 1 | 2019 | A Noninvasive Approach to Recovering the Lost Force Feedback for a Robotic-Assisted Insertable Laparoscopic Surgical Camera · ICRA 2019 |
Haptics and multimodal interaction › haptic feedback
force feedback |
0.4 | 1 | 2019 | A Noninvasive Approach to Recovering the Lost Force Feedback for a Robotic-Assisted Insertable Laparoscopic Surgical Camera · ICRA 2019 |
Medical and health informatics › surgical robotics
robot-assisted surgery |
0.3 | 1 | 2018 | Design and Test of an In-Vivo Robotic Camera Integrated with Optimized Illumination System for Single-port Laparoscopic Surgery · ICRA 2018 |
Medical and health informatics › surgical robotics
single port surgery |
0.2 | 1 | 2024 | Towards a Novel Soft Magnetic Laparoscope for Single Incision Laparoscopic Surgery · ICRA 2024 |
Robotics › Robot manipulation › medical robotics
capsule robot |
0.2 | 1 | 2014 | Design of a unified active locomotion mechanism for a capsule-shaped laparoscopic camera system · ICRA 2014 |
Robotics › Robot manipulation
medical robotics |
0.2 | 1 | 2014 | Design of a unified active locomotion mechanism for a capsule-shaped laparoscopic camera system · ICRA 2014 |
Robotics › Robot manipulation › human-robot interaction
shared autonomy |
0.1 | 1 | 2019 | A Noninvasive Approach to Recovering the Lost Force Feedback for a Robotic-Assisted Insertable Laparoscopic Surgical Camera · ICRA 2019 |
Methods — techniques the papers use, named apart from their topics
soft material design · 1.5magnetic anchoring and guidance · 1.5shared autonomy · 1.1real-time force measurement · 1.1magnetic coupling · 1.1viscoelastic modeling · 0.5geometric constraints · 0.5magnetic actuation · 0.43d rotational magnetic field · 0.4freeform optical lens design · 0.3
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2024 | Towards a Novel Soft Magnetic Laparoscope for Single Incision Laparoscopic SurgeryabstractIn single-incision laparoscopic surgery (SILS), magnetic anchoring and guidance system (MAGS) is a promising technique to prevent clutter in the surgical workspace and provide a larger vision field. Existing camera designs mainly rely on rigid structure design, resulting in risks of losing magnetic coupling and impacting tissue during the insertion and coupling procedure. In this paper, we proposed a wireless MAGS consisting of soft material and structure design. The camera can bend at the exit of the trocar and maintain strong coupling with the external actuator. The operation principle and modeling were established to investigate the parameter design. An easier insertion procedure was introduced and demonstrated in the experiment. The bendability was tested showing the camera could reach 20° in bending angle and 16.4mm in displacement. The insertion and deployment took less than 2 minutes on average. Shuai Li 0018, Gregory J. Mancini, Jindong Tan |
ICRA | 4 |
| 2021 | Recovering Stress Distribution on Deformable Tissue for a Magnetic Actuated Insertable Laparoscopic Surgical CameraabstractFully insertable laparoscopic cameras represent a promising future of minimally invasive surgery. The most characteristic technology adopted on these devices is transabdominal anchoring and actuation based on magnetic coupling. However, few have paid adequate attention to the safety concerns. As the camera is anchored against the interior abdominal wall without any force feedback, the patient is being exposed to a high risk of getting injured by inappropriate stress on the tissue. We have recovered the camera-tissue interaction force via a non-invasive approach in our previous work. Aiming to access the stress distribution, this paper presents a viscoelastic camera-tissue interaction model, which establishes explicit relations between the contact force and the stress distribution on the tissue. For the first time, a geometric constraint between the contact angle and the tissue indentation is introduced, which helps make the multivariable model solvable. Ex-vivo experiments on porcine abdomen tissue facilitated by non-invasive force measurement validate effectiveness of the model. This work lays foundation for improving control and surgical safety of using a magnetic actuated insertable laparoscopic surgical camera. Gregory J. Mancini, Amy Chandler, Jindong Tan |
ICRA | 2 |
| 2019 | A Noninvasive Approach to Recovering the Lost Force Feedback for a Robotic-Assisted Insertable Laparoscopic Surgical CameraabstractFully insertable laparoscopic cameras feature more locomotive flexibility in a larger workspace compared to conventional trocar-based laparoscopes and thus represent a promising future of minimally invasive surgery. These cameras are principally anchored and actuated by transabdominal magnetic coupling. Although several proof-of-concept prototypes have shown the technical feasibility in terms of camera actuation and laparoscopic imaging, none of them are getting close to clinical practice due to concerns about safety. One common problem lies in that the interaction force between the camera and the abdominal wall tissue is completely unknown and not controlled. The camera is being manipulated in an open loop which exposes the patient to a high risk of being injured. In this paper, a noninvasive real-time camera-tissue interaction force measurement approach for an insertable laparoscopic camera is proposed, implemented, and validated.Ex-vivo experiments using a simulated abdominal cavity have demonstrated the effectiveness of this approach during anchoring, translation, and rotation camera behaviors. Potential surgical impacts enabled by the force feedback have also been exemplified by a robotic-assisted camera control experiment using shared autonomy. Gregory J. Mancini, Jindong Tan |
ICRA | 2 |
| 2018 | Design and Test of an In-Vivo Robotic Camera Integrated with Optimized Illumination System for Single-port Laparoscopic SurgeryabstractThis paper proposes a novel in-vivo robotic laparo-scopic camera design with an optimized illumination system, which is a crucial component for achieving high imaging quality. The robotic camera design with three extendable wings can reserve sufficient on-board space to harbor the optimized illumination system without affecting the compactness of the camera. We contribute a freeform optical lens design method and develop three miniature optical lenses for the LEDs to achieve greater than 95% illumination uniformity, greater than 14, 000 lx illuminance on a target plane with a distance of 100 mm, and greater than 89% optical efficiency. The prototype is implemented and experimentally tested, which demonstrates great performance of the in-vivo robotic laparoscopic camera and the significance of the optimized illumination system. Xiaolong Liu 0002, Reza Yazdanpanah Abdolmalaki, Gregory J. Mancini, Jindong Tan |
ICRA | 5 |
| 2015 | Design and analysis of a magnetic actuated capsule camera robot for single incision laparoscopic surgeryabstractThis paper presents the design of a novel insertable robotic capsule camera system for single incision laparoscopic surgery. This design features a unified mechanism for anchoring, navigating, and rotating an insertable camera by externally generated rotational magnetic field. The design is inspired by the spherical motor concept where the external stator generates anchoring and rotational magnetic field to control the motion of the insertable robotic capsule camera. The insertable camera body, which has no active locomotion mechanism onboard, is capsulated in a one-piece housing with two ringshaped tail-end magnets and one cylindrical central magnet embedded on-board as a rotor. The stator positioned outside an abdominal cavity consists of both permanent magnets and electromagnetic coils for generating reliable rotational magnetic field. The initial prototype results in a compact insertable camera robot with a 12.7mm diameter and a 68mm length. The design concepts are analyzed theoretically and verified experimentally. The experiments validate that the proposed capsule robot design provides reliable camera fixation and locomotion capabilities under various testing conditions. Xiaolong Liu 0002, Gregory J. Mancini, Jindong Tan |
IROS | 2 |
| 2014 | Design of a unified active locomotion mechanism for a capsule-shaped laparoscopic camera systemabstractThis paper proposes a unified active locomotion mechanism for a capsule-shaped laparoscopic surgical camera system. The proposed design integrates the camera's fixation and manipulation together by adjusting a 3D rotational magnetic field from a stator outside a patient's body. The stator generates both torque to rotate the inside rotor dome in all three dimensions, and force to serve as an anchoring system that keeps the camera steady during a surgical procedure. This design eliminates the need for an articulated design and therefore the integrated motors to significantly reduce the size of the camera. A set of stator and rotor designs are developed and evaluated by simulations and experiments. Xiaolong Liu 0002, Gregory J. Mancini, Jindong Tan |
ICRA | 2 |
| 2014 | Design of a unified active locomotion mechanism for a wireless laparoscopic camera systemabstractThis paper proposes an active locomotion mechanism for a wireless laparoscopic surgical camera. The mechanism consists of a stator with 17 iron-core coils and a rotor with 3 cylindrical permanent magnets inside the camera. Our motor-free design unifies the camera's fixation and manipulation by adjusting input currents in the stator which generates 3D rotational magnetic fields, and decouples the camera's locomotion into pan motion and tilt motion. In the simulation studies, our proposed design can conservatively achieve 360° pan motion with a 22.5° resolution, and 127° ~ 164° maximum tilting range for tilt motion which depends on tilt motion working modes and the distance between the rotor and the stator. Xiaolong Liu 0002, Gregory J. Mancini, Jindong Tan |
IROS | 2 |