Demo Data from EDBT 2026 / reviewers in the wild / expert
Jan G. Grandjean
dblp:151/9622
· DBLP profile ↗
1ranked-venue papers
0as first author
0since 2021 · last 2014
—ORCID · unresolved
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% | |
| Artificial intelligence
1 paper |
Robot manipulation · 100% |
Topics — the 2 heaviest of 3, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Medical and health informatics
image-guided intervention |
0.2 | 1 | 2014 | A preliminary study on using a Robotically-Actuated Delivery Sheath (RADS) for transapical aortic valve implantation · ICRA 2014 |
Medical and health informatics
transcatheter aortic valve implantation |
0.2 | 1 | 2014 | A preliminary study on using a Robotically-Actuated Delivery Sheath (RADS) for transapical aortic valve implantation · ICRA 2014 |
Methods — techniques the papers use, named apart from their topics
ultrasound tracking · 0.4kinematic modeling · 0.4closed-loop control · 0.4
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2014 | A preliminary study on using a Robotically-Actuated Delivery Sheath (RADS) for transapical aortic valve implantationabstractRecent technological advancements in cardiovascular surgery such as transapical transcatheter aortic valve implantation (TA-TAVI) enabled treatment to elderly that were initially declined surgery. However, valve malpositioning during TA-TAVI have been reported in several cases. In this preliminary study, we present a novel approach in which a Robotically-Actuated Delivery Sheath (RADS) is used to potentially facilitate valve positioning. A model is developed that describes the shape and articulating tip position of the RADS. We developed a two-dimensional ultrasound tracking method that evaluates the tip position of the RADS in ultrasound images. Both modeling and ultrasound tracking are combined into an integrated system that facilitates closed-loop control of the articulating tip of the RADS. Experiments are performed in order to evaluate the tracking accuracy of the RADS. Experiments show mean positioning errors of approximately 2 mm along the x- and y-axes. Our study demonstrates that the RADS can potentially provide compensation for beating heart and respiratory motions during valve positioning and deployment in TA-TAVI. Gustaaf J. Vrooijink, Tim T. M. Ellenbroek, Paul Breedveld, Jan G. Grandjean, Sarthak Misra |
ICRA | 4 |