EDBT 2026 Demo / reviewers in the wild / expert
Christoph M. Augustin
dblp:173/5657
· DBLP profile ↗
7ranked-venue papers
0as first author
7since 2021 · last 2026
0000-0001-6341-4014ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 7 · 7 since 2021
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2026 | An efficient end-to-end computational framework for the generation of ECG calibrated volumetric models of human atrial electrophysiologyabstractComputational models of atrial electrophysiology (EP) are increasingly utilized for applications such as the development of advanced mapping systems, personalized clinical therapy planning, and the generation of virtual cohorts and digital twins. These models have the potential to establish robust causal links between simulated in silico behaviors and observed human atrial EP, enabling safer, cost-effective, and comprehensive exploration of atrial dynamics. However, current state-of-the-art approaches lack the fidelity and scalability required for regulatory-grade applications, particularly in creating high-quality virtual cohorts or patient-specific digital twins. Challenges include anatomically accurate model generation, calibration to sparse and uncertain clinical data, and computational efficiency within a streamlined workflow. This study addresses these limitations by introducing novel methodologies integrated into an automated end-to-end workflow for generating high-fidelity digital twin snapshots and virtual cohorts of atrial EP. These innovations include: (i) automated multi-scale generation of volumetric biatrial models with detailed anatomical structures and fiber architecture; (ii) a robust method for defining space-varying atrial parameter fields; (iii) a parametric approach for modeling inter-atrial conduction pathways; and (iv) an efficient forward EP model for high-fidelity electrocardiogram computation. We evaluated this workflow on a cohort of 50 atrial fibrillation patients, producing high-quality meshes suitable for reaction-eikonal and reaction-diffusion models and demonstrating the ability to simulate atrial ECGs under parametrically controlled conditions. These advancements represent a critical step toward scalable, precise, and clinically applicable digital twin models and virtual cohorts, enabling enhanced patient-specific predictions and therapeutic planning. Elena Zappon, Luca Azzolin, Matthias A. F. Gsell, Franz Thaler, Anton J. Prassl, Robert Arnold, Karli Gillette, Mohammadreza Kariman, Martin Manninger, Daniel Scherr, Aurel Neic, Martin Urschler, Christoph M. Augustin, Edward J. Vigmond, Gernot Plank |
Medical Image Anal. | 13 |
| 2025 | Regional heterogeneity in left atrial stiffness impacts passive deformation in a cohort of patient-specific modelsabstractIn atrial fibrillation (AF), atrial biomechanics are altered, reducing atrial movement. It remains unclear whether these changes are due to altered anatomy, myocardial stiffness, or constraints from surrounding structures. Understanding the causes of changed atrial deformation in AF could enhance tissue characterization and inform AF diagnosis, stratification, and treatment. We created patient-specific anatomical models of the left atrium (LA) from CT images. Passive LA biomechanics were simulated using finite deformation continuum mechanics equations. LA stiffness was represented by the Guccione material law, where α scaled the anisotropic stiffness parameters. Regional passive stiffness parameters were calibrated to peak regional deformation during the reservoir phase and validated against deformation transients derived from retrospective gated CT images during the reservoir and conduit phase. Physiological LA deformation varies regionally, with the roof deforming significantly less than other regions during the reservoir phase. The fitted model matched peak patient deformations globally and regionally with an average error of [Formula: see text] mm over our cohort. We compared deformation transients through the reservoir and conduit phases and found that the simulated deformation transients were within an average of [Formula: see text] mm per unit time of the CT-derived deformation transients. Regional stiffness varied across the atria with average α values of 1.8, 1.6, 2.2, 1.6 and 2.1 across the cohort in the anterior, posterior, septum, lateral and roof regions respectively. Using mixed effect models, we found no correlation between regional patient LA deformation and regional estimates of wall thickness or regional volumes of epicardial adipose tissue. We found a significant correlation between regionally calibrated stiffness and CT-derived LA biomechanics (p = 0.023). We have shown that regional heterogeneity in stiffness contributes to regional LA biomechanics, while anatomical features appeared less important. These findings provide insight into the underlying causes of altered LA biomechanics in AF. Tiffany M. G. Baptiste, Cristóbal Rodero, Charles Sillett, Marina Strocchi, Christopher W. Lanyon, Christoph M. Augustin, Angela W. C. Lee, José Alonso Solís-Lemus, Caroline H. Roney, Daniel B. Ennis, Ronak Rajani, C. Aldo Rinaldi, Gernot Plank, Richard Wilkinson, Steven Williams 0001, Steven A. Niederer |
PLoS Comput. Biol. | 6 |
| 2025 | Systematic computational assessment of atrial function impairment due to fibrotic remodeling in electromechanical propertiesabstractCardiac fibrosis is a pathological condition associated with many cardiovascular diseases. Atrial fibrosis leads to reduced atrial function, resulting in diminished blood flow and an increased risk of stroke. This reduced function arises from altered myocardial electrophysiological and mechanical properties. Identifying the relative importance of these fibrosis-associated properties can reveal the most significant determinants of left atrial function impairment. In this study, we used a computational framework to investigate the relative importance of various fibrosis-associated properties. Our model, a 3D electromechanical framework coupled with a 0D circulatory model, incorporated patient-specific geometries and fibrosis distributions from clinical imaging data. Nine parameters related to fibrotic remodeling (conduction velocity, ion channel expression levels, cell- and tissue-scale contractility, and stiffness) were analyzed using two sensitivity analysis schemes: a one-factor-at-a-time setup, allowing for analysis of isolated effects, and a fractional factorial design, enabling examination of combined effects. As output, we tracked various metrics derived from model-predicted pressure-volume loops. Impairment of L-type calcium current (ICaL) was most detrimental (up to 64% reduction in A-loop area of the left atrial pressure-volume relationship, quantifying work performed during atrial contraction). Conversely, reduced inward rectifier current (IK1) led to improved atrial function (up to 27% increase in A-loop area). Detailed analysis of spatiotemporal distributions linked these effects to changes in intracellular calcium handling. Fractional factorial design analysis revealed that combination with other parameter changes blunted the impact of reduced ICaL but amplified the impact of reduced IK1. Future research focusing on IK1 and ICaL could be highly significant for clinical and scientific advances. Modeling work can help evaluate left atrial function among larger patient cohorts, focusing on strain analysis. Our work could also be extended to spatiotemporal simulations of blood flow and thrombosis, shedding light onto the mechanisms underlying atriogenic stroke. Åshild Telle, Ahmad Kassar, Nadia Chamoun, Romanos Haykal, Alejandro Gonzalo, Tori Hensley, Yaacoub Chahine, Oscar Flores, Juan C. del Álamo, Nazem Akoum, Christoph M. Augustin, Patrick M. Boyle |
PLoS Comput. Biol. | 11 |
| 2023 | Cell to whole organ global sensitivity analysis on a four-chamber heart electromechanics model using Gaussian processes emulatorsabstractCardiac pump function arises from a series of highly orchestrated events across multiple scales. Computational electromechanics can encode these events in physics-constrained models. However, the large number of parameters in these models has made the systematic study of the link between cellular, tissue, and organ scale parameters to whole heart physiology challenging. A patient-specific anatomical heart model, or digital twin, was created. Cellular ionic dynamics and contraction were simulated with the Courtemanche-Land and the ToR-ORd-Land models for the atria and the ventricles, respectively. Whole heart contraction was coupled with the circulatory system, simulated with CircAdapt, while accounting for the effect of the pericardium on cardiac motion. The four-chamber electromechanics framework resulted in 117 parameters of interest. The model was broken into five hierarchical sub-models: tissue electrophysiology, ToR-ORd-Land model, Courtemanche-Land model, passive mechanics and CircAdapt. For each sub-model, we trained Gaussian processes emulators (GPEs) that were then used to perform a global sensitivity analysis (GSA) to retain parameters explaining 90% of the total sensitivity for subsequent analysis. We identified 45 out of 117 parameters that were important for whole heart function. We performed a GSA over these 45 parameters and identified the systemic and pulmonary peripheral resistance as being critical parameters for a wide range of volumetric and hemodynamic cardiac indexes across all four chambers. We have shown that GPEs provide a robust method for mapping between cellular properties and clinical measurements. This could be applied to identify parameters that can be calibrated in patient-specific models or digital twins, and to link cellular function to clinical indexes. Marina Strocchi, Stefano Longobardi, Christoph M. Augustin, Matthias A. F. Gsell, Argyrios Petras, C. Aldo Rinaldi, Edward J. Vigmond, Gernot Plank, Chris J. Oates, Richard Wilkinson, Steven A. Niederer |
PLoS Comput. Biol. | 3 |
| 2022 | Correction: Linking statistical shape models and simulated function in the healthy adult human heartabstract[This corrects the article DOI: 10.1371/journal.pcbi.1008851.]. Cristóbal Rodero, Marina Strocchi, Maciej Marciniak, Stefano Longobardi, John Whitaker, Mark D. O'Neill, Karli Gillette, Christoph M. Augustin, Gernot Plank, Edward J. Vigmond, Pablo Lamata, Steven A. Niederer |
PLoS Comput. Biol. | 8 |
| 2021 | A Framework for the generation of digital twins of cardiac electrophysiology from clinical 12-leads ECGsabstractCardiac digital twins (Cardiac Digital Twin (CDT)s) of human electrophysiology (Electrophysiology (EP)) are digital replicas of patient hearts derived from clinical data that match like-for-like all available clinical observations. Due to their inherent predictive potential, CDTs show high promise as a complementary modality aiding in clinical decision making and also in the cost-effective, safe and ethical testing of novel EP device therapies. However, current workflows for both the anatomical and functional twinning phases within CDT generation, referring to the inference of model anatomy and parameters from clinical data, are not sufficiently efficient, robust and accurate for advanced clinical and industrial applications. Our study addresses three primary limitations impeding the routine generation of high-fidelity CDTs by introducing; a comprehensive parameter vector encapsulating all factors relating to the ventricular EP; an abstract reference frame within the model allowing the unattended manipulation of model parameter fields; a novel fast-forward electrocardiogram (Electrocardiogram (ECG)) model for efficient and bio-physically-detailed simulation required for parameter inference. A novel workflow for the generation of CDTs is then introduced as an initial proof of concept. Anatomical twinning was performed within a reasonable time compatible with clinical workflows (<4h) for 12 subjects from clinically-attained magnetic resonance images. After assessment of the underlying fast forward ECG model against a gold standard bidomain ECG model, functional twinning of optimal parameters according to a clinically-attained 12 lead ECG was then performed using a forward Saltelli sampling approach for a single subject. The achieved results in terms of efficiency and fidelity demonstrate that our workflow is well-suited and viable for generating biophysically-detailed CDTs at scale. Karli Gillette, Matthias A. F. Gsell, Anton J. Prassl, Elias Karabelas, Ursula Reiter, Gert Reiter, Thomas Grandits, Christian Payer, Darko Stern, Martin Urschler, Jason D. Bayer, Christoph M. Augustin, Aurel Neic, Thomas Pock, Edward J. Vigmond, Gernot Plank |
Medical Image Anal. | 12 |
| 2021 | Linking statistical shape models and simulated function in the healthy adult human heartabstractCardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n = 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R = 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function. Cristóbal Rodero, Marina Strocchi, Maciej Marciniak, Stefano Longobardi, John Whitaker, Mark D. O'Neill, Karli Gillette, Christoph M. Augustin, Gernot Plank, Edward J. Vigmond, Pablo Lamata, Steven A. Niederer |
PLoS Comput. Biol. | 8 |