Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Richard B. Fair

dblp:18/4342 · DBLP profile ↗
← Back
15ranked-venue papers
6as first author
1since 2021 · last 2024
0000-0002-6728-1199ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Systems, architecture and hardware · 8 · 1 first-author · 1 since 2021Applied, interdisciplinary, general and emerging computing · 6 · 5 first-authorArtificial intelligence and machine learning · 1Software engineering, systems software and programming languages · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer architecture, parallel and distributed computing, and storage systems
9 papers
Electronic design automation · 92% Integrated circuit design · 3% Reconfigurable computing and FPGAs · 3%
Artificial intelligence
1 paper
Motion planning and robot control · 100%

Topics — the 22 heaviest of 23, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Electronic design automation
microfluidic biochip design
0.632020
Adaptive Droplet Routing in Digital Microfluidic Biochips Using Deep Reinforcement Learning · ICML 2020
Design Tools for Digital Microfluidic Biochips: Toward Functional Diversification and More Than Moore · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2010
Scheduling of microfluidic operations for reconfigurabletwo-dimensional electrowetting arrays · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2001
Electronic design automation › microfluidic biochip design
droplet routing
0.522020
Adaptive Droplet Routing in Digital Microfluidic Biochips Using Deep Reinforcement Learning · ICML 2020
Design Tools for Digital Microfluidic Biochips: Toward Functional Diversification and More Than Moore · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2010
Electronic design automation
physical design
0.522020
Adaptive Droplet Routing in Digital Microfluidic Biochips Using Deep Reinforcement Learning · ICML 2020
Scheduling of microfluidic operations for reconfigurabletwo-dimensional electrowetting arrays · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2001
Robotics › Motion planning and robot control › robot control › learning control
deep reinforcement learning control
0.112020
Adaptive Droplet Routing in Digital Microfluidic Biochips Using Deep Reinforcement Learning · ICML 2020
Electronic design automation › physical design › placement
module placement
0.112010
Design Tools for Digital Microfluidic Biochips: Toward Functional Diversification and More Than Moore · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2010
Electronic design automation › microfluidic biochip design
digital microfluidic biochip design
0.112006
Microfluidics-Based Biochips: Technology Issues, Implementation Platforms, and Design-Automation Challenges · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2006
Reconfigurable computing and FPGAs
dynamic reconfiguration
0.112006
Microfluidics-Based Biochips: Technology Issues, Implementation Platforms, and Design-Automation Challenges · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2006
Electronic design automation
hardware verification and test
0.112006
Microfluidics-Based Biochips: Technology Issues, Implementation Platforms, and Design-Automation Challenges · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2006
Electronic design automation › system-level design
system-level synthesis
0.112006
Microfluidics-Based Biochips: Technology Issues, Implementation Platforms, and Design-Automation Challenges · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2006
Electronic design automation
system-level design
0.012004
Behavioral modeling and performance evaluation of microelectrofluidics-based PCR systems using SystemC · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2004
Electronic design automation
hardware/software co-design
0.012002
Design of reconfigurable composite microsystems based on hardware/software codesign principles · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2002
Electronic design automation
hardware test
0.012010
Design Tools for Digital Microfluidic Biochips: Toward Functional Diversification and More Than Moore · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2010
Electronic design automation › high-level synthesis › scheduling
operation scheduling
0.012001
Scheduling of microfluidic operations for reconfigurabletwo-dimensional electrowetting arrays · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2001
Cloud and datacenter computing
resource allocation
0.012001
Scheduling of microfluidic operations for reconfigurabletwo-dimensional electrowetting arrays · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2001
Electronic design automation
semiconductor manufacturing
0.021998
History of some early developments in ion-implantation technology leading to silicon transistor manufacturing · Proc. IEEE 1998
Challenges to manufacturing submicron, ultra-large scale integrated circuits · Proc. IEEE 1990
Integrated circuit design › semiconductor process modeling
ion implantation
0.011998
History of some early developments in ion-implantation technology leading to silicon transistor manufacturing · Proc. IEEE 1998
Embedded and real-time systems
cyber-physical system platforms
0.012001
Scheduling of microfluidic operations for reconfigurabletwo-dimensional electrowetting arrays · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2001
Hardware accelerators and domain-specific architectures
lab-on-a-chip
0.012001
Scheduling of microfluidic operations for reconfigurabletwo-dimensional electrowetting arrays · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2001
Electronic design automation › technology computer-aided design › process simulation
dopant diffusion modeling
0.011991
Two-dimensional process simulation using verified phenomenological models · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 1991
Electronic design automation › technology computer-aided design
process simulation
0.011991
Two-dimensional process simulation using verified phenomenological models · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 1991
Electronic design automation › technology computer-aided design › process simulation
two-dimensional process simulation
0.011991
Two-dimensional process simulation using verified phenomenological models · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 1991
Integrated circuit design
semiconductor device modeling
0.011991
Two-dimensional process simulation using verified phenomenological models · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 1991

Methods — techniques the papers use, named apart from their topics

deep reinforcement learning · 0.9OpenAI Gym · 0.9synthesis · 0.1simulation · 0.1top-down design automation · 0.1systemc simulation · 0.0taguchi robust design · 0.0response surface methodology · 0.0integer linear programming · 0.0numerical simulation · 0.0
YearPublicationVenuePosition
2024 Dynamic Adaptation Using Deep Reinforcement Learning for Digital Microfluidic Biochips
abstract
We describe an exciting new application domain for deep reinforcement learning (RL): droplet routing on digital microfluidic biochips (DMFBs). A DMFB consists of a two-dimensional electrode array, and it manipulates droplets of liquid to automatically execute biochemical protocols for clinical chemistry. However, a major problem with DMFBs is that electrodes can degrade over time. The transportation of droplet transportation over these degraded electrodes can fail, thereby adversely impacting the integrity of the bioassay outcome. We demonstrated that the formulation of droplet transportation as an RL problem enables the training of deep neural network policies that can adapt to the underlying health conditions of electrodes and ensure reliable fluidic operations. We describe an RL-based droplet routing solution that can be used for various sizes of DMFBs. We highlight the reliable execution of an epigenetic bioassay with the RL droplet router on a fabricated DMFB. We show that the use of the RL approach on a simple micro-computer (Raspberry Pi 4) leads to acceptable performance for time-critical bioassays. We present a simulation environment based on the OpenAI Gym Interface for RL-guided droplet routing problems on DMFBs. We present results on our study of electrode degradation using fabricated DMFBs. The study supports the degradation model used in the simulator.
Tung-Che Liang, Yi-Chen Chang, Zhanwei Zhong, Yaas Bigdeli, Tsung-Yi Ho, Krishnendu Chakrabarty, Richard B. Fair
ACM Trans. Design Autom. Electr. Syst.7
2020 Adaptive Droplet Routing in Digital Microfluidic Biochips Using Deep Reinforcement Learning
abstract
We present and investigate a novel application domain for deep reinforcement learning (RL): droplet routing on digital microfluidic biochips (DMFBs). A DMFB, composed of a two-dimensional electrode array, manipulates discrete fluid droplets to automatically execute biochemical protocols such as point-of-care clinical diagnosis. However, a major concern associated with the use of DMFBs is that electrodes in a biochip can degrade over time. Droplet-transportation operations associated with the degraded electrodes can fail, thereby compromising the integrity of the bioassay outcome. We show that casting droplet transportation as an RL problem enables the training of deep network policies to capture the underlying health conditions of electrodes and to provide reliable fluidic operations. We propose a new RL-based droplet-routing flow that can be used for various sizes of DMFBs, and demonstrate reliable execution of an epigenetic bioassay with the RL droplet router on a fabricated DMFB. To facilitate further research, we also present a simulation environment based on the OpenAI Gym Interface for RL-guided droplet-routing problems on DMFBs.
Tung-Che Liang, Zhanwei Zhong, Yaas Bigdeli, Tsung-Yi Ho, Krishnendu Chakrabarty, Richard B. Fair
ICML6
2013 Fault detection, real-time error recovery, and experimental demonstration for digital microfluidic biochips
abstract
Advances in digital microfluidics and integrated sensing hold promise for a new generation of droplet-based biochips that can perform multiplexed assays to determine the identity of target molecules. Despite these benefits, defects and erroneous fluidic operations remain a major barrier to the adoption and deployment of these devices. We describe the first integrated demonstration of cyberphysical coupling in digital microfluidics, whereby errors in droplet transportation on the digital microfluidic platform are detected using capacitive sensors, the test outcome is interpreted by control hardware, and software-based error recovery is accomplished using dynamic reconfiguration. The hardware/software interface is realized through seamless interaction between control software, an off-the-shelf microcontroller and a frequency divider implemented on an FPGA. Experimental results are reported for a fabricated silicon device and links to videos are provided for the first-ever experimental demonstration of cyberphysical coupling and dynamic error recovery in digital microfluidic biochips.
Kai Hu 0003, Bang-Ning Hsu, Andrew Madison, Krishnendu Chakrabarty, Richard B. Fair
DATE5
2010 Design Tools for Digital Microfluidic Biochips: Toward Functional Diversification and More Than Moore
abstract
Microfluidics-based biochips enable the precise control of nanoliter volumes of biochemical samples and reagents. They combine electronics with biology, and they integrate various bioassay operations, such as sample preparation, analysis, separation, and detection. Compared to conventional laboratory procedures, which are cumbersome and expensive, miniaturized biochips offer the advantages of higher sensitivity, lower cost due to smaller sample and reagent volumes, system integration, and less likelihood of human error. This paper first describes the droplet-based “digital” microfluidic technology platform and emerging applications. The physical principles underlying droplet actuation are next described. Finally, the paper presents computer-aided design tools for simulation, synthesis and chip optimization. These tools target modeling and simulation, scheduling, module placement, droplet routing, pin-constrained chip design, and testing.
Krishnendu Chakrabarty, Richard B. Fair, Jun Zeng 0001
IEEE Trans. Comput. Aided Des. Integr. Circuits Syst.2
2006 Microfluidics-Based Biochips: Technology Issues, Implementation Platforms, and Design-Automation Challenges
abstract
Microfluidics-based biochips are soon expected to revolutionize clinical diagnosis, deoxyribonucleic acid (DNA) sequencing, and other laboratory procedures involving molecular biology. In contrast to continuous-flow systems that rely on permanently etched microchannels, micropumps, and microvalves, digital microfluidics offers a scalable system architecture and dynamic reconfigurability; groups of unit cells in a microfluidics array can be reconfigured to change their functionality during the concurrent execution of a set of bioassays. As more bioassays are executed concurrently on a biochip, system integration and design complexity are expected to increase dramatically. This paper presents an overview of an integrated system-level design methodology that attempts to address key issues in the synthesis, testing and reconfiguration of digital microfluidics-based biochips. Different actuation mechanisms for microfluidics-based biochips, and associated design-automation trends and challenges are also discussed. The proposed top-down design-automation approach is expected to relieve biochip users from the burden of manual optimization of bioassays, time-consuming hardware design, and costly testing and maintenance procedures, and it will facilitate the integration of fluidic components with a microelectronic component in next-generation systems-on-chips (SOCs).
Krishnendu Chakrabarty, Richard B. Fair
IEEE Trans. Comput. Aided Des. Integr. Circuits Syst.3
2004 Special Issue on Biomedical Applications for MEMS and Microfluidics
Abraham Lee, Richard B. Fair
Proc. IEEE2
2004 Behavioral modeling and performance evaluation of microelectrofluidics-based PCR systems using SystemC
abstract
Composite microsystems that incorporate microelectromechanical and microelectrofluidic devices are emerging as the next generation of system-on-a-chip (SOC). We present a performance comparison between two types of microelectrofluidic systems (MEFS): continuous-flow systems and droplet-based systems. The comparison is based on a specific microelectrofluidic application-a polymerase chain reaction (PCR) system. The behavioral modeling, simulation, and performance evaluation are based on a SystemC design environment. The performance comparison includes the system throughput, system-correction capacity, system-processing capacity, and system-design complexity. By using our system-performance evaluation environment, we demonstrated that the droplet-based MEFS provides higher performance, as well as lower design and integration complexity.
Krishnendu Chakrabarty, Richard B. Fair
IEEE Trans. Comput. Aided Des. Integr. Circuits Syst.3
2002 Design of reconfigurable composite microsystems based on hardware/software codesign principles
abstract
Composite microsystems that integrate mechanical and fluidic components with electronics are emerging as the next generation of system-on-a-chip. Custom microsystems are expensive, inflexible, and unsuitable for high-volume production. The authors address this problem by leveraging hardware/software codesign principles to design reconfigurable composite microsystems. They partition the system design parameters into nonreconfigurable and reconfigurable categories. In this way, operational flexibility is enhanced and the microsystems are designed for a wider range of application. In addition, the Taguchi robust design method is used to make the system robust, and response surface methodologies are used to explore the widest performance range for the system. A case study is presented for a microvalve, which serves as a representative microelectrofluidic device.
Krishnendu Chakrabarty, Richard B. Fair
IEEE Trans. Comput. Aided Des. Integr. Circuits Syst.3
2001 Scheduling of microfluidic operations for reconfigurabletwo-dimensional electrowetting arrays
abstract
We present an architectural design and optimization methodology for performing biochemical reactions using two-dimensional (2-D) electrowetting arrays. We define a set of basic microfluidic operations and leverage electronic design automation principles for system partitioning, resource allocation, and operation scheduling. Fluidic operations are carried out through the electrostatic configuration of a set of grid points. While concurrency is desirable to minimize processing time, the size of the 2-D array limits the number of concurrent operations of any type. Furthermore, functional dependencies between the operations also limit concurrency. We use integer linear programming to minimize the processing time by automatically extracting parallelism from a biochemical assay. As a case study, we apply our optimization method to the polymerase chain reaction, which is an important step in many lab-on-a-chip biochemical applications.
Krishnendu Chakrabarty, Richard B. Fair
IEEE Trans. Comput. Aided Des. Integr. Circuits Syst.3
1998 History of some early developments in ion-implantation technology leading to silicon transistor manufacturing
abstract
Ion implantation of dopant impurities to form p-n junctions and other doped regions in silicon transistors has evolved from an experimental curiosity in solid-state physics to become a dominant technology in today's integrated circuit manufacturing. This paper traces the key inventions and early developments in ion beam doping concepts from the early 1950's through the 1970's as they were applied to the development of metal-oxide-semiconductor (MOS) and bipolar transistors. Early on, scientists were fascinated with possible applications of radiation damage resulting from ion bombardment of semiconductors for building novel devices with room-temperature processing or, at most, maximum heating temperatures of a few hundred degrees Celsius. As a result, the early work initially overlooked the real potential of the technology for providing a highly controlled means of substitutional impurity doping in combination with high temperature annealing above 800/spl deg/C. Subsequently, a number of key researchers contributed to the knowledge base surrounding the penetration of energetic ions into semiconductors. However, the true potential of ion implantation would be realized by more device-oriented engineers driven by design and manufacturing issues who looked for ways of applying and integrating ion implantation with conventional transistor manufacturing methods. Ion implantation allowed for good lateral and vertical junction position control, which were critical elements as both device dimensions and patterned feature tolerances were reduced. Ion implantation, high-temperature annealing, and self-aligned silicon gate technology fueled new process technologies in MOS devices such as arsenic source/drain doping, the ability to tailor threshold voltages in both enhancement and depletion transistors, and lightly doped drain extensions. In bipolar technology, ion implantation would make possible tight control of base-region doping and reduction of parasitic resistances, and would enable the use of arsenic emitters for high-frequency applications of discrete transistors as well as advanced, high-speed integrated circuits.
Richard B. Fair
Proc. IEEE1
1997 Focus On The Future
Richard B. Fair, Jim Calder
Proc. IEEE1
1996 A Changing of the Guard, Editorial
Richard B. Fair
Proc. IEEE1
1993 Engineering research centers: goals and results [Scanning the Issue]
Richard B. Fair, Lynn Preston
Proc. IEEE1
1991 Two-dimensional process simulation using verified phenomenological models
abstract
Two-dimensional (2-D) effects are becoming increasingly important in the diffusion of impurities in submicrometer silicon devices. The authors describe a 2-D process simulator, PREDICT2, that handles implant damage effects, annealing, and lateral diffusion. PREDICT2 simulates the diffusion of impurities in silicon by using phenomenological diffusion coefficients. The phenomenological models are verified by comparing simulated and experimental results. This approach is compared with that of point-defect-based simulators. The experimental technique for measuring impurity profiles in two dimensions is outlined. The method for generating diffusion models is illustrated by examining 2-D phosphorous diffusion. Numerical simulations and experimental measurements are compared. The numerical methods used in the simulator are described, and directions for future work are suggested.>
Richard B. Fair, Carl L. Gardner, Michael J. Johnson, Stephen W. Kenkel, Donald J. Rose, John E. Rose, Ravi Subrahmanyan
IEEE Trans. Comput. Aided Des. Integr. Circuits Syst.1
1990 Challenges to manufacturing submicron, ultra-large scale integrated circuits
abstract
It is argued that the cost of manufacturing submicron, ultra-large-scale integration (ULSI) integrated circuits (ICs) (which is scaling upward at least in inverse proportion to the downward scaling of device feature sizes) is driven by a parameter budget crisis associated with the technological and complexity limits of IC design and fabrication. This budget crisis is defined for technologies associated with patterning, mechanical control, thermal treatments, particulates and contamination, defects, electrical parameters, and manufacturing, R&D priorities for silicon ULSI are identified and quantified, and the potential impact of some recent research results is discussed. It is pointed out that the R&D agenda to deal with the ULSI manufacturing budget crisis is enormous, and the semiconductor industry cannot perform all of it. Since the time for transferring new developments into production tools and technologies is five to seven years, it is concluded that critical funding decisions need to be made now for ULSI manufacturing science breakthroughs by the turn of the century.>
Richard B. Fair
Proc. IEEE1