Po-Hsien Yu

dblp:180/3656 · DBLP profile ↗
← Back
5ranked-venue papers
0as first author
0since 2021 · last 2018
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Systems, architecture and hardware · 5

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer architecture, parallel and distributed computing, and storage systems
3 papers
Electronic design automation · 74% Embedded and real-time systems · 14% Hardware reliability and fault tolerance · 12%

Topics — the 8 heaviest of 8, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Electronic design automation
hardware verification and test
0.722018
Structural and Functional Test Methods for Micro-Electrode-Dot-Array Digital Microfluidic Biochips · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2018
Efficient and Adaptive Error Recovery in a Micro-Electrode-Dot-Array Digital Microfluidic Biochip · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2018
Embedded and real-time systems
cyber-physical system platforms
0.422018
Efficient and Adaptive Error Recovery in a Micro-Electrode-Dot-Array Digital Microfluidic Biochip · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2018
High-level synthesis for micro-electrode-dot-array digital microfluidic biochips · DAC 2016
Electronic design automation › microfluidic biochip design
digital microfluidic biochip
0.422018
Efficient and Adaptive Error Recovery in a Micro-Electrode-Dot-Array Digital Microfluidic Biochip · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2018
High-level synthesis for micro-electrode-dot-array digital microfluidic biochips · DAC 2016
Hardware reliability and fault tolerance
error recovery
0.312018
Efficient and Adaptive Error Recovery in a Micro-Electrode-Dot-Array Digital Microfluidic Biochip · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2018
Electronic design automation › hardware verification and test
functional testing
0.312018
Structural and Functional Test Methods for Micro-Electrode-Dot-Array Digital Microfluidic Biochips · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2018
Electronic design automation › microfluidic biochip design
biochip synthesis
0.212016
High-level synthesis for micro-electrode-dot-array digital microfluidic biochips · DAC 2016
Electronic design automation
high-level synthesis
0.212016
High-level synthesis for micro-electrode-dot-array digital microfluidic biochips · DAC 2016
Electronic design automation
physical design
0.212016
High-level synthesis for micro-electrode-dot-array digital microfluidic biochips · DAC 2016

Methods — techniques the papers use, named apart from their topics

simulation · 0.3probabilistic timed automata · 0.3online synthesis · 0.3integer linear programming · 0.3fabricated chip experiment · 0.3operation scheduling · 0.2droplet routing · 0.2
YearPublicationVenuePosition
2018 Efficient and Adaptive Error Recovery in a Micro-Electrode-Dot-Array Digital Microfluidic Biochip
abstract
A digital microfluidic biochip (DMFB) is an attractive technology platform for automating laboratory procedures in biochemistry. In recent years, DMFBs based on a micro-electrode-dot-array (MEDA) architecture have been proposed. MEDA biochips can provide advantages of better capability of droplet manipulation and real-time sensing ability. However, errors are likely to occur due to defects, chip degradation, and the lack of precision inherent in biochemical experiments. Therefore, an efficient error-recovery strategy is essential to ensure the correctness of assays executed on MEDA biochips. By exploiting MEDA-specific advances in droplet sensing, we present a novel error-recovery technique to dynamically reconfigure the biochip using real-time data provided by on-chip sensors. Local recovery strategies based on probabilistic-timed-automata are presented for various types of errors. An online synthesis technique and a control flow are also proposed to connect local-recovery procedures with global error recovery for the complete bioassay. Moreover, an integer linear programming-based method is also proposed to select the optimal local-recovery time for each operation. Laboratory experiments using a fabricated MEDA chip are used to characterize the outcomes of key droplet operations. The PRISM model checker and three benchmarks are used for an extensive set of simulations. Our results highlight the effectiveness of the proposed error-recovery strategy.
Kelvin Yi-Tse Lai, John McCrone, Po-Hsien Yu, Krishnendu Chakrabarty, Miroslav Pajic, Tsung-Yi Ho, Chen-Yi Lee
IEEE Trans. Comput. Aided Des. Integr. Circuits Syst.4
2018 Structural and Functional Test Methods for Micro-Electrode-Dot-Array Digital Microfluidic Biochips
abstract
A digital microfluidic biochip (DMFB) is an attractive platform for immunoassays, point-of-care clinical diagnostics, DNA sequencing, and other laboratory procedures in biochemistry. More recently, DMFBs based on a micro-electrode-dot-array (MEDA) architecture have been proposed, and droplet manipulations on MEDA biochips have also been experimentally demonstrated. In order to ensure robust fluidic operations and high confidence in the outcome of biochemical experiments, MEDA biochips must be adequately tested before they can be used for bioassay execution. This paper presents the first approach for testing of MEDA biochips that include both CMOS circuits and microfluidic components. We first present structural test techniques to evaluate the pass/fail status of each microcell (droplet actuation, droplet maintenance, and droplet sensing) and identify faulty microcells. In order to ensure correct operation of functional units, e.g., mixers and diluters, we also present functional test techniques to address fundamental MEDA operations, such as droplet dispensing, transportation, mixing, and splitting. We evaluate the proposed test methods using simulations as well as experiments for fabricated MEDA biochips.
Kelvin Yi-Tse Lai, Po-Hsien Yu, Krishnendu Chakrabarty, Tsung-Yi Ho, Chen-Yi Lee
IEEE Trans. Comput. Aided Des. Integr. Circuits Syst.3
2016 High-level synthesis for micro-electrode-dot-array digital microfluidic biochips
abstract
A digital microfluidic biochip (DMFB) is an attractive technology platform for automating laboratory procedures in biochemistry. However, today's DMFBs suffer from several limitations: (i) constraints on droplet size and the inability to vary droplet volume in a fine-grained manner; (ii) the lack of integrated sensors for real-time detection; (iii) the need for special fabrication processes and reliability/yield concerns. To overcome the above problems, DMFBs based on a micro-electrode-dot-array (MEDA) architecture have recently been demonstrated. However, due to the inherent differences between today's DMFBs and MEDA, existing synthesis solutions cannot be utilized for MEDA-based biochips. We present the first biochip synthesis approach that can be used for MEDA. The proposed synthesis method targets operation scheduling, module placement, routing of droplets of various sizes, and diagonal movement of droplets in a two-dimensional array. Simulation results using benchmarks and experimental results using a fabricated MEDA biochip demonstrate the effectiveness of the proposed co-optimization technique.
Kelvin Yi-Tse Lai, Po-Hsien Yu, Tsung-Yi Ho, Krishnendu Chakrabarty, Chen-Yi Lee
DAC3
2016 Error recovery in a micro-electrode-dot-array digital microfluidic biochip?
abstract
A digital microfluidic biochip (DMFB) is an attractive technology platform for automating laboratory procedures in biochemistry. However, today's DMFBs suffer from several limitations: (i) constraints on droplet size and the inability to vary droplet volume in a fine-grained manner; (ii) the lack of integrated sensors for real-time detection; (iii) the need for special fabrication processes and the associated reliability/yield concerns. To overcome the above problems, DMFBs based on a micro-electrode-dot-array (MEDA) architecture have been proposed recently, and droplet manipulation on these devices has been experimentally demonstrated. Errors are likely to occur due to defects, chip degradation, and the lack of precision inherent in biochemical experiments. Therefore, an efficient error-recovery strategy is essential to ensure the correctness of assays executed on MEDA biochips. By exploiting MEDA-specific advances in droplet sensing, we present a novel error-recovery technique to dynamically reconfigure the biochip using real-time data provided by on-chip sensors. Local recovery strategies based on probabilistic-timed-automata are presented for various types of errors. A control flow is also proposed to connect local recovery procedures with global error recovery for the complete bioassay. Laboratory experiments using a fabricated MEDA chip are used to characterize the outcomes of key droplet operations. The PRISM model checker and three analytical chemistry benchmarks are used for an extensive set of simulations. Our results highlight the effectiveness of the proposed error-recovery strategy.
Kelvin Yi-Tse Lai, Po-Hsien Yu, Krishnendu Chakrabarty, Miroslav Pajic, Tsung-Yi Ho, Chen-Yi Lee
ICCAD3
2016 Built-in self-test for micro-electrode-dot-array digital microfluidic biochips
abstract
A digital microfluidic biochip (DMFB) is an attractive platform for immunoassays, point-of-care clinical diagnostics, DNA sequencing, and other laboratory procedures in biochemistry. However, today's DMFBs suffer from several limitations, including (i) the lack of integrated sensors for real-time detection, (ii) constraints on droplet size and the inability to vary droplet volume in a fine-grained manner, and (iii) the need for special fabrication processes and the associated reliability/yield concerns. To overcome the above limitations, DMFBs based on a micro-electrode-dot-array (MEDA) architecture have been proposed recently. Droplet manipulation on MEDA biochips has also been experimentally demonstrated. In order to ensure robust fluidic operations and high confidence in the outcome of biochemical experiments, MEDA biochips must be adequately tested before they can be used for bioassay execution. We present an efficient built-in self-test (BIST) architecture for MEDA biochips. The proposed BIST architecture can effectively detect defects in a MEDA biochip, and faulty microcells can be identified. Simulation results based on HSPICE and experiments using fabricated MEDA biochips highlight the effectiveness of the proposed BIST architecture.
Kelvin Yi-Tse Lai, Po-Hsien Yu, Krishnendu Chakrabarty, Tsung-Yi Ho, Chen-Yi Lee
ITC3