Hiroyuki Aihara

dblp:181/4041 · DBLP profile ↗
← Back
3ranked-venue papers
0as first author
1since 2021 · last 2022
—ORCID · conflict

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3 · 1 since 2021Systems, architecture and hardware · 3 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%
Computer graphics and multimedia
1 paper
Computational fabrication · 100%

Topics — the 2 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › surgical robotics
endoscopic surgery
0.212016
Snap-on robotic wrist module for enhanced dexterity in endoscopic surgery · ICRA 2016
Medical and health informatics
surgical robotics
0.212016
Snap-on robotic wrist module for enhanced dexterity in endoscopic surgery · ICRA 2016

Methods — techniques the papers use, named apart from their topics

shape memory alloy · 0.5proprioceptive sensing · 0.5light intensity modulation · 0.5
YearPublicationVenuePosition
2022 A Soft Robotic Haptic Feedback Glove for Colonoscopy Procedures
abstract
This paper presents a proof-of-concept soft robotic glove that provides haptic feedback to the surgeon's hand during interventional endoscopy procedures, specifically colonoscopy. The glove is connected to a force sensing soft robotic sleeve that is mounted onto a colonoscope. The glove consists of pneumatic actuators that inflate in proportion to the incident forces on the soft robotic sleeve. Thus, the glove is capable of alerting the surgeon of potentially dangerous forces exerted on the colon wall by the colonoscope during the navigation. The proposed glove is adaptable to a variety of hand sizes. It features modular actuators that facilitate convenient and rapid assembly and attachment before the procedure and removal afterward. The glove is calibrated to respond to incident forces on the soft robotic sleeve ranging from 0–3 N. The glove's actuators are able to reach an internal pressure of 53 kPa and exert forces up to 20 N, thereby relaying and amplifying the force exerted by the colonoscope on the colon to the surgeon's hand.
Arincheyan Gerald, Rukaiya Batliwala, Jonathan Ye, Patra Hsu, Hiroyuki Aihara, Sheila Russo
IROS5
2018 Fuzzy-Based Feedback Control of a Tip-Mounted Module for Robot-Assisted Endoscopy
abstract
Nascent endoscopic therapeutic procedures, such as endoscopic submucosal dissection, enable unparalleled access to and removal of mid-size cancerous neoplasia from within the gastrointestinal tract. However, the remote locations of these lesions often incur substantial distal dexterity which imparts appreciable cognitive loading on the clinician and opens up the possibility of adverse events such as intestinal perforation due to limited dexterity and a lack of sensory feedback. In this work, we introduce a mm-scale, tip-mounted robotic system, EndoMODRA (Endoscopic Module for On-Demand Robotic Assistance), which interfaces with commercially-available endoscopic tools and provides additional dexterity and feedback sensing using on-board actuators and sensors, decoupling tool motion from endoscope motion. Leveraging alternative high-energy-density actuation strategies and monolithic, printed-circuit-inspired manufacturing processes, all actuation and sensing is fully contained within the distally-mounted module, obviating the need for a continuous mechanical transmission to a proximal motor package. We develop a fuzzy-tuned PID/PWM controller for closing the loop distally to enable closed-loop position-controlled trajectory execution using onboard actuation and sensing, realizing fully -distal loop closure in an endoscope-mounted robotic module with no proximal actuation or sensing component. Controller performance is validated on a fully-integrated module with on-board sensing, demonstrating the ability to execute pre-determined trajectories as well as real-time rate-based teleoperation.
Joshua B. Gafford, Hiroyuki Aihara, Christopher Thompson 0003, Conor J. Walsh, Robert J. Wood
IROS2
2016 Snap-on robotic wrist module for enhanced dexterity in endoscopic surgery
abstract
Burgeoning transendoscopic procedures, such as endoscopic submucosal dissection (ESD), provide a promising means of treating early-stage gastric neoplasia in a minimally-invasive way. However, the remote locations of these lesions, coupled with their origination in the submucosal layers of the gastrointestinal tract, often lead to extreme technical, cognitive and ergonomic challenges which combat the widespread applicability and adoption of these techniques. Among these challenges is achieving the in vivo dexterity required to retract and dissect tissue. By leveraging workspace and force data obtained through clinical studies, we developed a modular, disposable, distally-mounted actuator (an `active endcap') that can augment an endoscopist's distal dexterity in ways that are not achievable with the endoscope's built-in degrees-of-freedom. The device consists of a flexible articulating `exoskeleton' manufactured via printed-circuit MEMS (PCMEMS) which engages and deflects electrosurgical tools that are passed through the endoscopic working channel. Embedded proprioceptive sensing is implemented on-board using distributed LED/phototransistor pairs and the principle of light intensity modulation (LIM). The distal degree-of-freedom is actuated using shape memory alloy (SMA) technology, and the actuation transmission system is fully contained within a 1-inch-long end cap that can be mounted on the distal end of the endoscope, thereby obviating the need for a mechanical connection to a proximal source. Proof-of-concept tests demonstrate that the actuator adds over 50 degrees of distal articulation to existing tools and can generate 450 mN of lateral force which has been clinically determined to be sufficient for performing circumferential incisions in ESD.
Joshua B. Gafford, Tommaso Ranzani, Sheila Russo, Hiroyuki Aihara, Christopher Thompson 0003, Robert J. Wood, Conor J. Walsh
ICRA4