Jeroen Veltman

dblp:201/5713 · DBLP profile ↗
← Back
3ranked-venue papers
0as first author
1since 2021 · last 2023
0000-0002-6824-3987ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3 · 1 since 2021Systems, architecture and hardware · 3 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Robot manipulation · 81% Motion planning and robot control · 19%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Robot manipulation › medical robotics
MRI-compatible robot
0.312017
Controlling the Stormram 2: An MRI-compatible robotic system for breast biopsy · ICRA 2017
Robotics › Robot manipulation › actuator design
pneumatic actuation
0.112017
Controlling the Stormram 2: An MRI-compatible robotic system for breast biopsy · ICRA 2017
Robotics › Motion planning and robot control
robot control
0.112017
Controlling the Stormram 2: An MRI-compatible robotic system for breast biopsy · ICRA 2017

Methods — techniques the papers use, named apart from their topics

valve manifold control · 0.3
YearPublicationVenuePosition
2023 Sunram 7: An MR Safe Robotic System for Breast Biopsy
abstract
In breast cancer patients, some nodules are only visible on MRI, thus, requiring MRI-guidance to perform the biopsy. MRI interventions are cumbersome due to the magnetic field and the constrained working space. An MR safe robotic system actuated by pneumatic stepper motors may enable these procedures, improving both accuracy and image-guided navigation. A compact multipurpose pneumatic stepper motor has been designed with outer dimensions$(45 \times 40\times 15)\mathbf{mm}^{\mathbf{3}}$. This is configurable as a linear, rotational or curved stepper motor with a customizable step size and radius of curvature. Five copies of these motors actuate the Sunram 7 biopsy robot, of which the moving part (without protruding racks and tubes) measures$(130 \times 65\times 55)\mathbf{mm}^{\mathbf{3}}$. After manually choosing the target location and angle of approach, the needle is robotically inserted into the breast and the integrated pneumatic biopsy gun is fired to sample tissue from the lesion. The maximum torque of the presented motor is 0.61 N m at 6 bar which can be achieved using 13-teeth polycarbonate gears. Using 17-teeth gears for higher accuracy and a more convenient working pressure of 2 bar the maximum torque is 0.28 N m. The accuracy in free air of the Sunram 7 robot is 1.69mm and 1.72mm in X and Z-direction respectively, with a resulting 2-D error of 2.54 mm. The workspace volume is 4.1 L. When targeting 10 mm-sized lesions in phantoms under MRI guidance, Sunram 7 achieved a success rate of 68%. The minimum interval between two successive biopsies was 5:47 minutes. The presented multipurpose stepper motor has distinct advantages over previous designs in terms of robustness, customizability, printability and ease of integration in MR safe robotics. The Sunram 7 is able to perform accurate MRI-guided biopsies in a large workspace volume while reducing the intervention time when compared to the gold standard (i.e., MRI-guided free-hand biopsy).
Harsh Ranjan, Marijn Van Hilten, Vincent Groenhuis, Juan Verde, Alain Garcia, Silvana Perretta, Jeroen Veltman, Françoise J. Siepel, Stefano Stramigioli
IROS7
2017 Controlling the Stormram 2: An MRI-compatible robotic system for breast biopsy
abstract
Breast cancer is the most frequently life-threatening diagnosed type of cancer among women. Early and accurate diagnosis by acquiring a tissue sample using biopsy techniques is essential. However, small lesions only visible by MRI are often missed in standard methods, indicating the need for a robotic-assisted biopsy system that is MRI-compatible. Existing proof-of-concepts are difficult to employ due to large sizes and/or actuation complexities. Therefore, a compact pneumatically-actuated 5 DOF MRI-compatible robot was further developed and controlled by a computerized valve manifold. Accuracy and efficiency measurements have been performed using two different PVC breast phantoms with embedded fish oil capsules (mimicking lesions) inside a 0.25T MRI scanner. Preliminary results show that the end-effector was able to hit the targeted capsules, and that the position accuracy is in the range of 4.7-7.3 mm. The developed robotic system has potential to perform MRI-guided breast biopsies accurately and improve the clinical workflow.
Mohamed E. M. K. Abdelaziz, Vincent Groenhuis, Jeroen Veltman, Françoise J. Siepel, Stefano Stramigioli
ICRA3
2017 Design and characterization of Stormram 4: An MRI-compatible robotic system for breast biopsy
abstract
Targeting of small lesions with high precision is essential in an early phase of breast cancer for diagnosis and accurate follow up, and subsequently determines prognosis. Current techniques to diagnose breast cancer are suboptimal, and there is a need for a small, MRI-compatible robotic system able to target lesions with high precision and direct feedback of MRI. Therefore, the design and working mechanism of the new Stormram 4, an MRI-compatible needle manipulator with four degrees of freedom, will be presented to take biopsies of small lesions in the MRI scanner. Its dimensions (excluding racks and needle) are 72×51×40 mm, and the system is driven by two linear and two curved pneumatic stepper motors. The T-26 linear motor measures 26×21×16 mm, has a nominal step size of 0.25 mm and the measured maximum force is 63N at 0.65 MPa. The workspace has a total volume of 2.2 L. Accuracy measurements have shown that the mean positioning error is 0.7 mm, with a reproducibility of 0.1 mm. Velocity measurements with 5 m long tubes show a maximum stepping frequency of 8 Hz (maximum force) to 30 Hz (unloaded). These results show that the robot might be able to target lesions with sub-millimeter accuracy within reasonable time for the MRI-guided breast biopsy procedure.
Vincent Groenhuis, Françoise J. Siepel, Jeroen Veltman, Stefano Stramigioli
IROS3