Deepak Raina

dblp:210/6518 · DBLP profile ↗
← Back
4ranked-venue papers
3as first author
3since 2021 · last 2025
0000-0002-5863-6111ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4 · 3 first-author · 3 since 2021Systems, architecture and hardware · 3 · 2 first-author · 3 since 2021Human-computer interaction and ubiquitous computing · 1 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 1 · 1 first-author
YearPublicationVenuePosition
2025 Robotic Ultrasound-Guided Femoral Artery Reconstruction of Anatomically-Representative Phantoms
abstract
Femoral artery access is essential for numerous clinical procedures, including diagnostic angiography, therapeutic catheterization, and emergency interventions. Despite its critical role, successful vascular access remains challenging due to anatomical variability, overlying adipose tissue, and the need for precise ultrasound (US) guidance. Needle placement errors can result in severe complications, thereby limiting the procedure to highly skilled clinicians operating in controlled hospital environments. While robotic systems have shown promise in addressing these challenges through autonomous scanning and vessel reconstruction, clinical translation remains limited due to reliance on simplified phantom models that fail to capture human anatomical complexity. In this work, we present a method for autonomous robotic US scanning of bifurcated femoral arteries, and validate it on five vascular phantoms created from real patient computed tomography (CT) data. Additionally, we introduce a video-based deep learning US segmentation network tailored for vascular imaging, enabling improved 3D arterial reconstruction. The proposed network achieves a Dice score of 89.21% and an Intersection over Union of 80.54% on a new vascular dataset. The reconstructed artery centerline is evaluated against ground truth CT data, showing an average L2error of 0.91±0.70 mm, with an average Hausdorff distance of 4.36±1.11mm. This study is the first to validate an autonomous robotic system for US scanning of the femoral artery on a diverse set of patient-specific phantoms, introducing a more advanced framework for evaluating robotic performance in vascular imaging and intervention.
Lidia Al-Zogbi, Deepak Raina, Vinciya Pandian, Thorsten Fleiter, Axel Krieger
IROS2
2023 Expert-Agnostic Ultrasound Image Quality Assessment using Deep Variational Clustering
abstract
Ultrasound imaging is a commonly used modality for several diagnostic and therapeutic procedures. However, the diagnosis by ultrasound relies heavily on the quality of images assessed manually by sonographers, which diminishes the objectivity of the diagnosis and makes it operator-dependent. The supervised learning-based methods for automated quality assessment require manually annotated datasets, which are highly labour-intensive to acquire. These ultrasound images are low in quality and suffer from noisy annotations caused by inter-observer perceptual variations, which hampers learning efficiency. We propose an UnSupervised UltraSound image Quality assessment Network, US2QNet, that eliminates the burden and uncertainty of manual annotations. US2QNet uses the variational autoencoder embedded with the three modules, pre-processing, clustering and post-processing, to jointly enhance, extract, cluster and visualize the quality feature representation of ultrasound images. The pre-processing module uses filtering of images to point the network's attention towards salient quality features, rather than getting distracted by noise. Post-processing is proposed for visualizing the clusters of feature representations in 2D space. We validated the proposed framework for quality assessment of the urinary bladder ultrasound images. The proposed framework achieved 78% accuracy and superior performance to state-of-the-art clustering methods. The project page with source codes is available at https://sites.google.com/view/US2QNet.
Deepak Raina, Dimitrios Ntentia, Chandrashekhara SH, Richard M. Voyles, Subir Kumar Saha
ICRA1
2023 Robotic Sonographer: Autonomous Robotic Ultrasound using Domain Expertise in Bayesian Optimization
abstract
Ultrasound is a vital imaging modality utilized for a variety of diagnostic and interventional procedures. However, an expert sonographer is required to make accurate maneuvers of the probe over the human body while making sense of the ultrasound images for diagnostic purposes. This procedure requires a substantial amount of training and up to a few years of experience. In this paper, we propose an autonomous robotic ultrasound system that uses Bayesian Optimization (BO) in combination with the domain expertise to predict and effectively scan the regions where diagnostic quality ultrasound images can be acquired. The quality map, which is a distribution of image quality in a scanning region, is estimated using Gaussian process in BO. This relies on a prior quality map modeled using expert's demonstration of the high-quality probing maneuvers. The ultrasound image quality feedback is provided to BO, which is estimated using a deep convolution neural network model. This model was previously trained on database of images labelled for diagnostic quality by expert radiologists. Experiments on three different urinary bladder phantoms validated that the proposed autonomous ultrasound system can acquire ultrasound images for diagnostic purposes with a probing position and force accuracy of 98.7% and 97.8%, respectively.
Deepak Raina, Chandrashekhara SH, Richard M. Voyles, Juan P. Wachs, Subir Kumar Saha
ICRA1
2019 A Novel Image-based Path Planning Algorithm for Eye-in-Hand Visual Servoing of a Redundant Manipulator in a Human Centered Environment
abstract
This paper presents a novel image-based path-planning and execution framework for vision-based control of a robot in a human centered environment. The proposed method involves applying Rapidly-exploring Random Tree (RRT) exploration to perform Image-Based Visual Servoing (IBVS) while satisfying multiple task constraints by exploiting robot redundancy. The methodology incorporates data-set of robot's workspace images for path-planning and design a controller based on visual servoing framework. This method is generic enough to include constraints like Field-of-View (FoV) limits, joint limits, obstacles, various singularities, occlusions etc. in the planning stage itself using task function approach and thereby avoiding them during the execution. The use of path-planning eliminates many of the inherent limitations of IBVS with eye-in-hand configuration and makes the use of visual servoing practical for dynamic and complex environments. Several experiments have been performed on a UR5 robotic manipulator to demonstrate that it is an effective and robust way to guide a robot in such environments.
Deepak Raina, P. Mithun, Suril Vijaykumar Shah
RO-MAN1