Demo Data from EDBT 2026 / reviewers in the wild / expert
Justin D. L. Ho
dblp:221/4315 · also Justin Di-Lang Ho
· DBLP profile ↗
4ranked-venue papers
0as first author
4since 2021 · last 2026
0000-0001-6280-1135ORCID · verified
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 4 · 4 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
3 papers |
Motion planning and robot control · 37% Segmentation and scene understanding · 24% 3D vision · 24% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 5 heaviest of 8, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Computer vision › 3D vision › object pose estimation
instrument pose estimation |
1.0 | 1 | 2026 | Real-Time Monocular 2-D and 3-D Perception of Endoluminal Scenes for Controlling Flexible Robotic Endoscopic Instruments · IEEE Trans. Robotics 2026 |
Robotics › Motion planning and robot control › robot learning › data-driven control
koopman-based control |
0.7 | 1 | 2023 | A Fast Soft Robotic Laser Sweeping System Using Data-Driven Modeling Approach · IEEE Trans. Robotics 2023 |
Robotics › Motion planning and robot control
robot control |
0.7 | 1 | 2023 | A Fast Soft Robotic Laser Sweeping System Using Data-Driven Modeling Approach · IEEE Trans. Robotics 2023 |
Medical and health informatics
computer-assisted intervention |
0.6 | 1 | 2022 | Shape Tracking and Feedback Control of Cardiac Catheter Using MRI-Guided Robotic Platform - Validation With Pulmonary Vein Isolation Simulator in MRI · IEEE Trans. Robotics 2022 |
Robotics › Motion planning and robot control
motion planning |
0.2 | 1 | 2023 | A Fast Soft Robotic Laser Sweeping System Using Data-Driven Modeling Approach · IEEE Trans. Robotics 2023 |
Methods — techniques the papers use, named apart from their topics
tracking coils · 1.1learning-based modeling · 1.1fiber bragg grating sensing · 1.1monocular vision · 1.0learning-based perception · 1.0koopman operator · 0.7fiber optic shape sensing · 0.7disturbance observer · 0.7
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2026 | Real-Time Monocular 2-D and 3-D Perception of Endoluminal Scenes for Controlling Flexible Robotic Endoscopic InstrumentsabstractEndoluminal surgery offers a minimally invasive option for early-stage gastrointestinal and urinary tract, but is limited by basic surgical tools and a steep learning curve. Robotic systems, particularly continuum robots, provide flexible instruments that enable precise, intuitive tissue resection in confined spaces, potentially improving outcomes. This paper presents an integrated visual perception platform for a continuum robotic system in endoluminal surgery. Our objective is to leverage monocular endoscopic image-based perception algorithms to accurately identify the position and orientation of flexible instruments and measure their distances from surrounding tissues. This thorough understanding of continuum robots and surgical scenes enhances the robustness of robotic procedures. We introduce 2D and 3D learning-based perception algorithms and develop a physically-realistic simulator that models the dynamics of flexible instruments. This simulator features a pipeline for generating realistic endoluminal scenes, enabling control of flexible robots in a realistic environment and substantial data collection. Using a continuum robot prototype, we conducted extensive evaluations, including module assessments and system-level evaluation of the perception platform. Results demonstrate that our perception algorithms significantly improve control of flexible instruments, reducing manipulation time by over 70% for trajectory-following tasks and enhancing the understanding of complex surgical scenarios, leading to robust endoluminal surgeries. Ruofeng Wei, Kai Chen 0024, Yui-Lun Ng, Yiyao Ma, Justin D. L. Ho, Hon-Sing Tong, Ka-Wai Kwok, Qi Dou 0001 |
IEEE Trans. Robotics | 5 |
| 2024 | Omnidirectional Monolithic Marker for Intra-Operative MR-Based Positional Sensing in Closed MRIabstractWe present a design of an inductively coupled radio frequency (ICRF) marker for magnetic resonance (MR)-based positional tracking, enabling the robust increase of tracking signal at all scanning orientations in quadrature-excited closed MR imaging (MRI). The marker employs three curved resonant circuits fully covering a cylindrical surface that encloses the signal source. Each resonant circuit is a planar spiral inductor with parallel plate capacitors fabricated monolithically on flexible printed circuit board (FPC) and bent to achieve the curved structure. Size of the constructed marker is Ø3-mm ×5 -mm with quality factor > 22, and its tracking performance was validated with 1.5 T MRI scanner. As result, the marker remains as a high positive contrast spot under 360° rotations in 3 axes. The marker can be accurately localized with a maximum error of 0.56 mm under a displacement of 56 mm from the isocenter, along with an inherent standard deviation of 0.1-mm. Accrediting to the high image contrast, the presented marker enables automatic and real-time tracking in 3D without dependency on its orientation with respect to the MRI scanner receive coil. In combination with its small form-factor, the presented marker would facilitate robust and wireless MR-based tracking for intervention and clinical diagnosis. This method targets applications that can involve rotational changes in all axes (X-Y-Z). Chim Lee Cheung, Ge Fang, Justin D. L. Ho, Liyuan Liang, Kel Vin Tan, Fa-Hsuan Lin, Hing-Chiu Chang, Ka-Wai Kwok |
IEEE Trans. Medical Imaging | 4 |
| 2023 | A Fast Soft Robotic Laser Sweeping System Using Data-Driven Modeling ApproachabstractSoft robots have great potential in surgical applications due to their compliance and adaptability to their environment. However, their flexibility and nonlinearity bring challenges for precise modeling, sensing, and control, especially in constrained cavities. In this article, a simple, compact two-segment soft robot for flexible laser ablation is proposed. The proximal hydraulic-driven segment can offer omnidirectional bending so as to navigate toward lesions. The distal segment driven by tendons enables precise, fast steering of laser collimator for laser sweeping on lesion targets. The dynamics of such mechanical steering motion can be enhanced with a metal spring backbone integrated along the collimator, thus facilitating the control with certain linearity and responsiveness. A soft robot modeling and control scheme based on Koopman operators is proposed. We also design a disturbance observer so as to incorporate the controller feedback with real-time fiber optic shape sensing. Experimental validation is conducted on simulated orex-vivolaser ablation tasks, thus evaluating our control strategies in laser path following across various contours/patterns. As a result, such a simple compact laser manipulation can perform up to 6 Hz sweeping with precision of path following errors below 1 mm. Such modeling and control scheme could also be used on an endoscopic laser ablation robot with unsymmetric mechanism driven by two tendons. Kui Wang 0002, Justin D. L. Ho, Ge Fang, Bohao Zhu, Rongying Xie, Yun-Hui Liu 0001, K. W. Samuel Au, Jason Ying-Kuen Chan, Ka-Wai Kwok |
IEEE Trans. Robotics | 3 |
| 2022 | Shape Tracking and Feedback Control of Cardiac Catheter Using MRI-Guided Robotic Platform - Validation With Pulmonary Vein Isolation Simulator in MRIabstractCardiac electrophysiology is an effective treatment for atrial fibrillation, in which a long, steerable catheter is inserted into the heart chamber to conduct radio frequency ablation. Magnetic resonance imaging (MRI) can provide enhanced intraoperative monitoring of the ablation progress as well as the localization of catheter position. However, accurate and real-time tracking of the catheter shape and its efficient manipulation under MRI remains challenging. In this article, we designed a shape tracking system that integrates a multicore fiber Bragg grating (FBG) fiber and tracking coils with a standard cardiac catheter. Both the shape and positional tracking of the bendable section could be achieved. A learning-based modeling method is developed for cardiac catheters, which uses FBG-reconstructed three-dimensional curvatures for model initialization. The proposed modeling method was implemented on an MRI-guided robotic platform to achieve feedback control of a cardiac catheter. The shape tracking performance was experimentally verified, demonstrating 2.33° average error for each sensing segment and 1.53 mm positional accuracy at the catheter tip. The feedback control performance was tested by autonomous targeting and path following (average deviation of 0.62 mm) tasks. The overall performance of the integrated robotic system was validated by a pulmonary vein isolation simulator withex-vivotissue ablation, which employed a left atrial phantom with pulsatile liquid flow. Catheter tracking and feedback control tests were conducted in an MRI scanner, demonstrating the capability of the proposed system under MRI. Ziyang Dong, Ge Fang, Zhuoliang He, Justin D. L. Ho, Chim Lee Cheung, Wai Lun Tang, Xiaochen Xie, Liyuan Liang, Hing-Chiu Chang, Chi Keong Ching, Ka-Wai Kwok |
IEEE Trans. Robotics | 5 |