Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data.

Ryan Remy Brinkman

dblp:222/5000 · DBLP profile ↗
← Back
12ranked-venue papers
0as first author
0since 2021 · last 2018
0000-0002-9765-2990ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 12

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
7 papers
Bioinformatics and computational biology · 100%

Topics — the 5 heaviest of 6, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Bioinformatics and computational biology › single-cell analysis
cytometry data analysis
1.362018
flowLearn: fast and precise identification and quality checking of cell populations in flow cytometry · Bioinform. 2018
Deep profiling of multitube flow cytometry data · Bioinform. 2015
flowDensity: reproducing manual gating of flow cytometry data by automated density-based cell population identification · Bioinform. 2015
Bioinformatics and computational biology › single-cell analysis
cell population identification
0.522018
flowLearn: fast and precise identification and quality checking of cell populations in flow cytometry · Bioinform. 2018
flowDensity: reproducing manual gating of flow cytometry data by automated density-based cell population identification · Bioinform. 2015
Bioinformatics and computational biology
immunophenotyping
0.532015
Deep profiling of multitube flow cytometry data · Bioinform. 2015
Enhanced flowType/RchyOptimyx: a Bioconductor pipeline for discovery in high-dimensional cytometry data · Bioinform. 2014
flowCL: ontology-based cell population labelling in flow cytometry · Bioinform. 2015
Bioinformatics and computational biology › single-cell analysis › cytometry data analysis
automated gating
0.312018
flowLearn: fast and precise identification and quality checking of cell populations in flow cytometry · Bioinform. 2018
Bioinformatics and computational biology › drug discovery
high-throughput screening
0.112015
flowDensity: reproducing manual gating of flow cytometry data by automated density-based cell population identification · Bioinform. 2015

Methods — techniques the papers use, named apart from their topics

clustering · 0.5shiny app · 0.3semi-supervised learning · 0.3density alignment · 0.3ontology-based semantic labelling · 0.2nearest-neighbour imputation · 0.2density-based gating · 0.2classification · 0.2multivariate statistical analysis · 0.1feature selection · 0.1
YearPublicationVenuePosition
2018 ddPCRclust: an R package and Shiny app for automated analysis of multiplexed ddPCR data
abstract
Motivation: Droplet digital PCR (ddPCR) is an emerging technology for quantifying DNA. By partitioning the target DNA into ∼20 000 droplets, each serving as its own PCR reaction compartment, a very high sensitivity of DNA quantification can be achieved. However, manual analysis of the data is time consuming and algorithms for automated analysis of non-orthogonal, multiplexed ddPCR data are unavailable, presenting a major bottleneck for the advancement of ddPCR transitioning from low-throughput to high-throughput. Results: ddPCRclust is an R package for automated analysis of data from Bio-Rad's droplet digital PCR systems (QX100 and QX200). It can automatically analyze and visualize multiplexed ddPCR experiments with up to four targets per reaction. Results are on par with manual analysis, but only take minutes to compute instead of hours. The accompanying Shiny app ddPCRvis provides easy access to the functionalities of ddPCRclust through a web-browser based GUI. Availability and implementation: R package: https://github.com/bgbrink/ddPCRclust; Interface: https://github.com/bgbrink/ddPCRvis/; Web: https://bibiserv.cebitec.uni-bielefeld.de/ddPCRvis/. Supplementary information: Supplementary data are available at Bioinformatics online.
Benedikt G. Brink, Justin Meskas, Ryan Remy Brinkman
Bioinform.3
2018 flowLearn: fast and precise identification and quality checking of cell populations in flow cytometry
abstract
Motivation: Identification of cell populations in flow cytometry is a critical part of the analysis and lays the groundwork for many applications and research discovery. The current paradigm of manual analysis is time consuming and subjective. A common goal of users is to replace manual analysis with automated methods that replicate their results. Supervised tools provide the best performance in such a use case, however they require fine parameterization to obtain the best results. Hence, there is a strong need for methods that are fast to setup, accurate and interpretable. Results: flowLearn is a semi-supervised approach for the quality-checked identification of cell populations. Using a very small number of manually gated samples, through density alignments it is able to predict gates on other samples with high accuracy and speed. On two state-of-the-art datasets, our tool achieves median(F1)-measures exceeding 0.99 for 31%, and 0.90 for 80% of all analyzed populations. Furthermore, users can directly interpret and adjust automated gates on new sample files to iteratively improve the initial training. Availability and implementation: FlowLearn is available as an R package on https://github.com/mlux86/flowLearn. Evaluation data is publicly available online. Details can be found in the Supplementary Material. Supplementary information: Supplementary data are available at Bioinformatics online.
Markus Lux, Ryan Remy Brinkman, Cédric Chauve, Adam Laing, Anna Lorenc, Lucie Abeler-Dörner, Barbara Hammer
Bioinform.2
2015 flowCL: ontology-based cell population labelling in flow cytometry
abstract
MOTIVATION: Finding one or more cell populations of interest, such as those correlating to a specific disease, is critical when analysing flow cytometry data. However, labelling of cell populations is not well defined, making it difficult to integrate the output of algorithms to external knowledge sources. RESULTS: We developed flowCL, a software package that performs semantic labelling of cell populations based on their surface markers and applied it to labelling of the Federation of Clinical Immunology Societies Human Immunology Project Consortium lyoplate populations as a use case. CONCLUSION: By providing automated labelling of cell populations based on their immunophenotype, flowCL allows for unambiguous and reproducible identification of standardized cell types. AVAILABILITY AND IMPLEMENTATION: Code, R script and documentation are available under the Artistic 2.0 license through Bioconductor (http://www.bioconductor.org/packages/devel/bioc/html/flowCL.html). CONTACT: [email protected] SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.
Mélanie Courtot, Justin Meskas, Alexander D. Diehl, Radina Droumeva, Raphael Gottardo, Adrin Jalali, Mohammad Jafar Taghiyar, Holden T. Maecker, J. Philip McCoy, Alan Ruttenberg, Richard H. Scheuermann, Ryan Remy Brinkman
Bioinform.12
2015 flowDensity: reproducing manual gating of flow cytometry data by automated density-based cell population identification
abstract
SUMMARY: flowDensity facilitates reproducible, high-throughput analysis of flow cytometry data by automating a predefined manual gating approach. The algorithm is based on a sequential bivariate gating approach that generates a set of predefined cell populations. It chooses the best cut-off for individual markers using characteristics of the density distribution. The Supplementary Material is linked to the online version of the manuscript. AVAILABILITY AND IMPLEMENTATION: R source code freely available through BioConductor (http://master.bioconductor.org/packages/devel/bioc/html/flowDensity.html.). Data available from FlowRepository.org (dataset FR-FCM-ZZBW). CONTACT: [email protected] SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.
Mehrnoush Malek, Mohammad Jafar Taghiyar, Lauren Chong, Greg Finak, Raphael Gottardo, Ryan Remy Brinkman
Bioinform.6
2015 Deep profiling of multitube flow cytometry data
abstract
Abstract Motivation: Deep profiling the phenotypic landscape of tissues using high-throughput flow cytometry (FCM) can provide important new insights into the interplay of cells in both healthy and diseased tissue. But often, especially in clinical settings, the cytometer cannot measure all the desired markers in a single aliquot. In these cases, tissue is separated into independently analysed samples, leaving a need to electronically recombine these to increase dimensionality. Nearest-neighbour (NN) based imputation fulfils this need but can produce artificial subpopulations. Clustering-based NNs can reduce these, but requires prior domain knowledge to be able to parameterize the clustering, so is unsuited to discovery settings. Results: We present flowBin, a parameterization-free method for combining multitube FCM data into a higher-dimensional form suitable for deep profiling and discovery. FlowBin allocates cells to bins defined by the common markers across tubes in a multitube experiment, then computes aggregate expression for each bin within each tube, to create a matrix of expression of all markers assayed in each tube. We show, using simulated multitube data, that flowType analysis of flowBin output reproduces the results of that same analysis on the original data for cell types of >10% abundance. We used flowBin in conjunction with classifiers to distinguish normal from cancerous cells. We used flowBin together with flowType and RchyOptimyx to profile the immunophenotypic landscape of NPM1-mutated acute myeloid leukemia, and present a series of novel cell types associated with that mutation. Availability and implementation: FlowBin is available in Bioconductor under the Artistic 2.0 free open source license. All data used are available in FlowRepository under accessions: FR-FCM-ZZYA, FR-FCM-ZZZK and FR-FCM-ZZES. Contact: [email protected]. Supplementary information: Supplementary data are available at Bioinformatics online.
Kieran O'Neill, Nima Aghaeepour, Jeremy Parker, Donna Hogge, Aly Karsan, Bakul Dalal, Ryan Remy Brinkman
Bioinform.7
2014 Enhanced flowType/RchyOptimyx: a Bioconductor pipeline for discovery in high-dimensional cytometry data
abstract
Abstract Summary: We present a significantly improved version of the flowType and RchyOptimyx BioConductor-based pipeline that is both 14 times faster and can accommodate multiple levels of biomarker expression for up to 96 markers. With these improvements, the pipeline is positioned to be an integral part of data analysis for high-throughput experiments on high-dimensional single-cell assay platforms, including flow cytometry, mass cytometry and single-cell RT-qPCR. Availability: FlowType and RchyOptimyx are distributed under the Artistic 2.0 license through Bioconductor. Contact: [email protected]
Kieran O'Neill, Adrin Jalali, Nima Aghaeepour, Holger H. Hoos, Ryan Remy Brinkman
Bioinform.5
2013 Flow Cytometry Bioinformatics
abstract
Flow cytometry bioinformatics is the application of bioinformatics to flow cytometry data, which involves storing, retrieving, organizing, and analyzing flow cytometry data using extensive computational resources and tools. Flow cytometry bioinformatics requires extensive use of and contributes to the development of techniques from computational statistics and machine learning. Flow cytometry and related methods allow the quantification of multiple independent biomarkers on large numbers of single cells. The rapid growth in the multidimensionality and throughput of flow cytometry data, particularly in the 2000s, has led to the creation of a variety of computational analysis methods, data standards, and public databases for the sharing of results. Computational methods exist to assist in the preprocessing of flow cytometry data, identifying cell populations within it, matching those cell populations across samples, and performing diagnosis and discovery using the results of previous steps. For preprocessing, this includes compensating for spectral overlap, transforming data onto scales conducive to visualization and analysis, assessing data for quality, and normalizing data across samples and experiments. For population identification, tools are available to aid traditional manual identification of populations in two-dimensional scatter plots (gating), to use dimensionality reduction to aid gating, and to find populations automatically in higher dimensional space in a variety of ways. It is also possible to characterize data in more comprehensive ways, such as the density-guided binary space partitioning technique known as probability binning, or by combinatorial gating. Finally, diagnosis using flow cytometry data can be aided by supervised learning techniques, and discovery of new cell types of biological importance by high-throughput statistical methods, as part of pipelines incorporating all of the aforementioned methods. Open standards, data, and software are also key parts of flow cytometry bioinformatics. Data standards include the widely adopted Flow Cytometry Standard (FCS) defining how data from cytometers should be stored, but also several new standards under development by the International Society for Advancement of Cytometry (ISAC) to aid in storing more detailed information about experimental design and analytical steps. Open data is slowly growing with the opening of the CytoBank database in 2010 and FlowRepository in 2012, both of which allow users to freely distribute their data, and the latter of which has been recommended as the preferred repository for MIFlowCyt-compliant data by ISAC. Open software is most widely available in the form of a suite of Bioconductor packages, but is also available for web execution on the GenePattern platform.
Kieran O'Neill, Nima Aghaeepour, Josef Spidlen, Ryan Remy Brinkman
PLoS Comput. Biol.4
2012 Early immunologic correlates of HIV protection can be identified from computational analysis of complex multivariate T-cell flow cytometry assays
abstract
MOTIVATION: Polychromatic flow cytometry (PFC), has enormous power as a tool to dissect complex immune responses (such as those observed in HIV disease) at a single cell level. However, analysis tools are severely lacking. Although high-throughput systems allow rapid data collection from large cohorts, manual data analysis can take months. Moreover, identification of cell populations can be subjective and analysts rarely examine the entirety of the multidimensional dataset (focusing instead on a limited number of subsets, the biology of which has usually already been well-described). Thus, the value of PFC as a discovery tool is largely wasted. RESULTS: To address this problem, we developed a computational approach that automatically reveals all possible cell subsets. From tens of thousands of subsets, those that correlate strongly with clinical outcome are selected and grouped. Within each group, markers that have minimal relevance to the biological outcome are removed, thereby distilling the complex dataset into the simplest, most clinically relevant subsets. This allows complex information from PFC studies to be translated into clinical or resource-poor settings, where multiparametric analysis is less feasible. We demonstrate the utility of this approach in a large (n=466), retrospective, 14-parameter PFC study of early HIV infection, where we identify three T-cell subsets that strongly predict progression to AIDS (only one of which was identified by an initial manual analysis). AVAILABILITY: The 'flowType: Phenotyping Multivariate PFC Assays' package is available through Bioconductor. Additional documentation and examples are available at: www.terryfoxlab.ca/flowsite/flowType/ SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online. CONTACT: [email protected].
Nima Aghaeepour, Pratip K. Chattopadhyay, Anuradha Ganesan, Kieran O'Neill, Habil Zare, Adrin Jalali, Holger H. Hoos, Mario Roederer, Ryan Remy Brinkman
Bioinform.9
2010 Data reduction for spectral clustering to analyze high throughput flow cytometry data
abstract
BACKGROUND: Recent biological discoveries have shown that clustering large datasets is essential for better understanding biology in many areas. Spectral clustering in particular has proven to be a powerful tool amenable for many applications. However, it cannot be directly applied to large datasets due to time and memory limitations. To address this issue, we have modified spectral clustering by adding an information preserving sampling procedure and applying a post-processing stage. We call this entire algorithm SamSPECTRAL. RESULTS: We tested our algorithm on flow cytometry data as an example of large, multidimensional data containing potentially hundreds of thousands of data points (i.e., "events" in flow cytometry, typically corresponding to cells). Compared to two state of the art model-based flow cytometry clustering methods, SamSPECTRAL demonstrates significant advantages in proper identification of populations with non-elliptical shapes, low density populations close to dense ones, minor subpopulations of a major population and rare populations. CONCLUSIONS: This work is the first successful attempt to apply spectral methodology on flow cytometry data. An implementation of our algorithm as an R package is freely available through BioConductor.
Habil Zare, Parisa Shooshtari, Arvind Gupta, Ryan Remy Brinkman
BMC Bioinform.4
2009 flowCore: a Bioconductor package for high throughput flow cytometry
abstract
BACKGROUND: Recent advances in automation technologies have enabled the use of flow cytometry for high throughput screening, generating large complex data sets often in clinical trials or drug discovery settings. However, data management and data analysis methods have not advanced sufficiently far from the initial small-scale studies to support modeling in the presence of multiple covariates. RESULTS: We developed a set of flexible open source computational tools in the R package flowCore to facilitate the analysis of these complex data. A key component of which is having suitable data structures that support the application of similar operations to a collection of samples or a clinical cohort. In addition, our software constitutes a shared and extensible research platform that enables collaboration between bioinformaticians, computer scientists, statisticians, biologists and clinicians. This platform will foster the development of novel analytic methods for flow cytometry. CONCLUSION: The software has been applied in the analysis of various data sets and its data structures have proven to be highly efficient in capturing and organizing the analytic work flow. Finally, a number of additional Bioconductor packages successfully build on the infrastructure provided by flowCore, open new avenues for flow data analysis.
Florian Hahne, Nolwenn Le Meur, Ryan Remy Brinkman, Byron Ellis, Perry Haaland, Deepayan Sarkar, Josef Spidlen, Errol Strain, Robert Gentleman
BMC Bioinform.3
2009 flowClust: a Bioconductor package for automated gating of flow cytometry data
abstract
BACKGROUND: As a high-throughput technology that offers rapid quantification of multidimensional characteristics for millions of cells, flow cytometry (FCM) is widely used in health research, medical diagnosis and treatment, and vaccine development. Nevertheless, there is an increasing concern about the lack of appropriate software tools to provide an automated analysis platform to parallelize the high-throughput data-generation platform. Currently, to a large extent, FCM data analysis relies on the manual selection of sequential regions in 2-D graphical projections to extract the cell populations of interest. This is a time-consuming task that ignores the high-dimensionality of FCM data. RESULTS: In view of the aforementioned issues, we have developed an R package called flowClust to automate FCM analysis. flowClust implements a robust model-based clustering approach based on multivariate t mixture models with the Box-Cox transformation. The package provides the functionality to identify cell populations whilst simultaneously handling the commonly encountered issues of outlier identification and data transformation. It offers various tools to summarize and visualize a wealth of features of the clustering results. In addition, to ensure its convenience of use, flowClust has been adapted for the current FCM data format, and integrated with existing Bioconductor packages dedicated to FCM analysis. CONCLUSION: flowClust addresses the issue of a dearth of software that helps automate FCM analysis with a sound theoretical foundation. It tends to give reproducible results, and helps reduce the significant subjectivity and human time cost encountered in FCM analysis. The package contributes to the cytometry community by offering an efficient, automated analysis platform which facilitates the active, ongoing technological advancement.
Kenneth Lo, Florian Hahne, Ryan Remy Brinkman, Raphael Gottardo
BMC Bioinform.3
2009 FuGEFlow: data model and markup language for flow cytometry
abstract
BACKGROUND: Flow cytometry technology is widely used in both health care and research. The rapid expansion of flow cytometry applications has outpaced the development of data storage and analysis tools. Collaborative efforts being taken to eliminate this gap include building common vocabularies and ontologies, designing generic data models, and defining data exchange formats. The Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) standard was recently adopted by the International Society for Advancement of Cytometry. This standard guides researchers on the information that should be included in peer reviewed publications, but it is insufficient for data exchange and integration between computational systems. The Functional Genomics Experiment (FuGE) formalizes common aspects of comprehensive and high throughput experiments across different biological technologies. We have extended FuGE object model to accommodate flow cytometry data and metadata. METHODS: We used the MagicDraw modelling tool to design a UML model (Flow-OM) according to the FuGE extension guidelines and the AndroMDA toolkit to transform the model to a markup language (Flow-ML). We mapped each MIFlowCyt term to either an existing FuGE class or to a new FuGEFlow class. The development environment was validated by comparing the official FuGE XSD to the schema we generated from the FuGE object model using our configuration. After the Flow-OM model was completed, the final version of the Flow-ML was generated and validated against an example MIFlowCyt compliant experiment description. RESULTS: The extension of FuGE for flow cytometry has resulted in a generic FuGE-compliant data model (FuGEFlow), which accommodates and links together all information required by MIFlowCyt. The FuGEFlow model can be used to build software and databases using FuGE software toolkits to facilitate automated exchange and manipulation of potentially large flow cytometry experimental data sets. Additional project documentation, including reusable design patterns and a guide for setting up a development environment, was contributed back to the FuGE project. CONCLUSION: We have shown that an extension of FuGE can be used to transform minimum information requirements in natural language to markup language in XML. Extending FuGE required significant effort, but in our experiences the benefits outweighed the costs. The FuGEFlow is expected to play a central role in describing flow cytometry experiments and ultimately facilitating data exchange including public flow cytometry repositories currently under development.
Olga Tchuvatkina, Josef Spidlen, Peter Wilkinson, Maura Gasparetto, Andrew R. Jones, Frank J. Manion, Richard H. Scheuermann, Rafick-Pierre Sekaly, Ryan Remy Brinkman
BMC Bioinform.10