Demo Data from EDBT 2026 / reviewers in the wild / expert
Xuanchun Yin
dblp:238/3993
· DBLP profile ↗
2ranked-venue papers
1as first author
1since 2021 · last 2024
0000-0003-0488-0642ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 1 · 1 first-author · 1 since 2021Systems, architecture and hardware · 1 · 1 first-author · 1 since 2021Applied, interdisciplinary, general and emerging computing · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
1 paper |
Robot manipulation · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% | |
| Human-computer interaction and pervasive computing
1 paper |
Haptics and multimodal interaction · 100% |
Topics — the 5 heaviest of 5, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation
grasping |
0.8 | 1 | 2024 | A Helical Bistable Soft Gripper Enable by Pneumatic Actuation · ICRA 2024 |
Robotics › Robot manipulation › actuator design
pneumatic actuation |
0.8 | 1 | 2024 | A Helical Bistable Soft Gripper Enable by Pneumatic Actuation · ICRA 2024 |
Robotics › Robot manipulation › grasping
soft gripper |
0.8 | 1 | 2024 | A Helical Bistable Soft Gripper Enable by Pneumatic Actuation · ICRA 2024 |
Medical and health informatics › surgical robotics
robot-assisted surgery |
0.4 | 1 | 2019 | A Novel Robot-Assisted Endovascular Catheterization System With Haptic Force Feedback · IEEE Trans. Robotics 2019 |
Haptics and multimodal interaction › haptic feedback
force feedback |
0.4 | 1 | 2019 | A Novel Robot-Assisted Endovascular Catheterization System With Haptic Force Feedback · IEEE Trans. Robotics 2019 |
Methods — techniques the papers use, named apart from their topics
pseudocollision detection · 0.8pneumatic actuation · 0.8magnetorheological fluids · 0.8force modeling · 0.8bistable mechanism · 0.83d printing · 0.8
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2024 | A Helical Bistable Soft Gripper Enable by Pneumatic ActuationabstractThere are many instances of helical mechanisms that are used to efficiently grasp different objects with various shapes and sizes in nature. Inspired by the helical grasping in the nature, we proposed a helical bistable soft gripper with high load capacity and energy saving. An off-the-shelf bistable steel shell (BSS) as the stiff element was inserted into a 3D printing soft helical exoskeleton to achieve coiling around and holding the objects without energy consumption. Two air pouches were designed as the actuator to control the transition between the two stable states. To facilitate gripper design, a simplified model of the gripper was conducted, and the geometric parameters of the gripper are listed in a table for reference. The transition pressures between the two stable states were experimentally characterized. Moreover, we conduct experiments to demonstrate the capability of the gripper in two working modes. The gripper exhibits coiling diameters ranging between 40 mm and 60 mm and is successfully attached to various slender objects of different geometries with a maximum holding force of 92.67 N (up to 135.1 times of its mass) in hanging mode. Finally, the gripper was integrated into a robot arm and successfully grasped different objects, and the maximum grasping weight is 221.6 g in the grasping mode. Xuanchun Yin, Junliang Xie, Sheng Wen |
ICRA | 1 |
| 2019 | A Novel Robot-Assisted Endovascular Catheterization System With Haptic Force FeedbackabstractThe robot-assisted endovascular catheterization system (RAECS) has the potential to address some of the procedural challenges and separate interventionalists from the X-ray radiation during the endovascular surgery. However, the employment of robotic systems is partly changing the natural gestures and behavior of medical professionals. This paper presents a RAECS that augments surgeon's motions using the conventional catheter as well as generates the haptic force feedback to ensure surgery safety. The magnetorheological fluids based haptic interfaceexperiment is proposed to measure the actions of the operator and provide the haptic force. The slave catheter manipulator is presented to actuate the patient catheter in two degrees of freedom (radial and axial direction). In addition, a force model is provided to characterize the kinematics of the catheter intervention. Afterward, the “pseudocollision” and “real collision” are utilized to descript the catheter tip–vessel interaction. Thein vitroresults are presented, which demonstrate that catheter-based haptic force feedback has a benefit for improving catheterization skills as well as reducing the cognitive workload of operators. Shuxiang Guo, Yu Song 0004, Xuanchun Yin, Linshuai Zhang, Takashi Tamiya, Hideyuki Hirata, Hidenori Ishihara |
IEEE Trans. Robotics | 3 |