Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Xingjian Yang

dblp:24/3272 · DBLP profile ↗
← Back
2ranked-venue papers
0as first author
0since 2021 · last 2020
0009-0002-3632-3840ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1Systems, architecture and hardware · 1Applied, interdisciplinary, general and emerging computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Motion planning and robot control · 87% Robot manipulation · 13%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Motion planning and robot control › robot calibration
kinematic calibration
0.412020
Real-time Data Driven Precision Estimator for RAVEN-II Surgical Robot End Effector Position · ICRA 2020
Robotics › Motion planning and robot control
robot control
0.412020
Real-time Data Driven Precision Estimator for RAVEN-II Surgical Robot End Effector Position · ICRA 2020
Medical and health informatics
surgical robotics
0.412020
Real-time Data Driven Precision Estimator for RAVEN-II Surgical Robot End Effector Position · ICRA 2020
Robotics › Robot manipulation
cable-driven robot
0.112020
Real-time Data Driven Precision Estimator for RAVEN-II Surgical Robot End Effector Position · ICRA 2020

Methods — techniques the papers use, named apart from their topics

neural network regression · 0.9data-driven estimation · 0.9
YearPublicationVenuePosition
2020 Real-time Data Driven Precision Estimator for RAVEN-II Surgical Robot End Effector Position
abstract
Surgical robots have been introduced to operating rooms over the past few decades due to their high sensitivity, small size, and remote controllability. The cable-driven nature of many surgical robots allows the systems to be dexterous and lightweight, with diameters as low as 5mm. However, due to the slack and stretch of the cables and the backlash of the gears, inevitable uncertainties are brought into the kinematics calcu-lation [1]. Since the reported end effector position of surgical robots like RAVEN-II [2] is directly calculated using the motor encoder measurements and forward kinematics, it may contain relatively large error up to 10mm, whereas semi-autonomous functions being introduced into abdominal surgeries require position inaccuracy of at most 1mm. To resolve the problem, a cost-effective, real-time and data-driven pipeline for robot end effector position precision estimation is proposed and tested on RAVEN-II. Analysis shows an improved end effector position error of around 1mm RMS traversing through the entire robot workspace without high-resolution motion tracker. The open source code, data sets, videos, and user guide can be found at //github.com/HaonanPeng/RAVEN Neural Network Estimator.
Haonan Peng 0002, Xingjian Yang, Yun-Hsuan Su, Blake Hannaford
ICRA2
2005 Development and Test of an Artificial-Immune- Abnormal-Trading-Detection System for Financial Markets
Vincent Cheng-Siong Lee, Xingjian Yang
ICIC (1)2