Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Arian Mehrfard

dblp:245/8870 · DBLP profile ↗
← Back
2ranked-venue papers
0as first author
2since 2021 · last 2024
0000-0003-2800-3548ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1 · 1 since 2021Systems, architecture and hardware · 1 · 1 since 2021Applied, interdisciplinary, general and emerging computing · 1 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
3D vision · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Computer vision › 3D vision › 3d shape analysis
shape estimation
0.812024
Uncertainty-Aware Shape Estimation of a Surgical Continuum Manipulator in Constrained Environments using Fiber Bragg Grating Sensors · ICRA 2024
Medical and health informatics
surgical robotics
0.812024
Uncertainty-Aware Shape Estimation of a Surgical Continuum Manipulator in Constrained Environments using Fiber Bragg Grating Sensors · ICRA 2024

Methods — techniques the papers use, named apart from their topics

uncertainty estimation · 1.5out-of-distribution detection · 1.5deep neural network · 1.5
YearPublicationVenuePosition
2024 Uncertainty-Aware Shape Estimation of a Surgical Continuum Manipulator in Constrained Environments using Fiber Bragg Grating Sensors
abstract
Continuum Dexterous Manipulators (CDMs) are well-suited tools for minimally invasive surgery due to their inherent dexterity and reachability. Nonetheless, their flexible structure and non-linear curvature pose significant challenges for shape-based feedback control. The use of Fiber Bragg Grating (FBG) sensors for shape sensing has shown great potential in estimating the CDM’s tip position and subsequently reconstructing the shape using optimization algorithms. This optimization, however, is under-constrained and may be ill-posed for complex shapes, falling into local minima. In this work, we introduce a novel method capable of directly estimating a CDM’s shape from FBG sensor wavelengths using a deep neural network. In addition, we propose the integration of uncertainty estimation to address the critical issue of uncertainty in neural network predictions. Neural network predictions are unreliable when the input sample is outside the training distribution or corrupted by noise. Recognizing such deviations is crucial when integrating neural networks within surgical robotics, as inaccurate estimations can pose serious risks to the patient. We present a robust method that not only improves the precision upon existing techniques for FBG-based shape estimation but also incorporates a mechanism to quantify the models’ confidence through uncertainty estimation. We validate the uncertainty estimation through extensive experiments, demonstrating its effectiveness and reliability on out-of-distribution (OOD) data, adding an additional layer of safety and precision to minimally invasive surgical robotics.
Alexander Schwarz, Arian Mehrfard, Golchehr Amirkhani, Henry Phalen, Justin H. Ma, Robert B. Grupp, Alejandro Martin-Gomez, Mehran Armand
ICRA2
2021 Development and Pre-Clinical Analysis of Spatiotemporal-Aware Augmented Reality in Orthopedic Interventions
abstract
Suboptimal interaction with patient data and challenges in mastering 3D anatomy based on ill-posed 2D interventional images are essential concerns in image-guided therapies. Augmented reality (AR) has been introduced in the operating rooms in the last decade; however, in image-guided interventions, it has often only been considered as a visualization device improving traditional workflows. As a consequence, the technology is gaining minimum maturity that it requires to redefine new procedures, user interfaces, and interactions. The main contribution of this paper is to reveal how exemplary workflows are redefined by taking full advantage of head-mounted displays when entirely co-registered with the imaging system at all times. The awareness of the system from the geometric and physical characteristics of X-ray imaging allows the exploration of different human-machine interfaces. Our system achieved an error of 4.76 ± 2.91mm for placing K-wire in a fracture management procedure, and yielded errors of 1.57 ± 1.16° and 1.46 ± 1.00° in the abduction and anteversion angles, respectively, for total hip arthroplasty (THA). We compared the results with the outcomes from baseline standard operative and non-immersive AR procedures, which had yielded errors of [4.61mm, 4.76°, 4.77°] and [5.13mm, 1.78°, 1.43°], respectively, for wire placement, and abduction and anteversion during THA. We hope that our holistic approach towards improving the interface of surgery not only augments the surgeon's capabilities but also augments the surgical team's experience in carrying out an effective intervention with reduced complications and provide novel approaches of documenting procedures for training purposes.
Javad Fotouhi, Arian Mehrfard, Tianyu Song 0002, Alex Johnson, Greg Osgood, Mathias Unberath, Mehran Armand, Nassir Navab
IEEE Trans. Medical Imaging2