Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Lieven Clement

dblp:25/10258 · DBLP profile ↗
← Back
9ranked-venue papers
0as first author
0since 2021 · last 2017
0000-0002-9050-4370ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 9

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
3 papers
Bioinformatics and computational biology · 100%

Topics — the 8 heaviest of 9, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Bioinformatics and computational biology › genomics › variant calling
low-frequency variant detection
0.212015
VirVarSeq: a low-frequency virus variant detection pipeline for Illumina sequencing using adaptive base-calling accuracy filtering · Bioinform. 2015
Bioinformatics and computational biology
sequence analysis
0.212015
VirVarSeq: a low-frequency virus variant detection pipeline for Illumina sequencing using adaptive base-calling accuracy filtering · Bioinform. 2015
Bioinformatics and computational biology › genomics › computational genomics
SNP detection
0.212015
VirVarSeq: a low-frequency virus variant detection pipeline for Illumina sequencing using adaptive base-calling accuracy filtering · Bioinform. 2015
Bioinformatics and computational biology › genomics
viral genomics
0.212015
VirVarSeq: a low-frequency virus variant detection pipeline for Illumina sequencing using adaptive base-calling accuracy filtering · Bioinform. 2015
Bioinformatics and computational biology › gene expression analysis
differential expression analysis
0.212014
unifiedWMWqPCR: the unified Wilcoxon-Mann-Whitney test for analyzing RT-qPCR data in R · Bioinform. 2014
Bioinformatics and computational biology
gene expression analysis
0.212014
unifiedWMWqPCR: the unified Wilcoxon-Mann-Whitney test for analyzing RT-qPCR data in R · Bioinform. 2014
Bioinformatics and computational biology › gene expression analysis › differential expression analysis
nonparametric testing
0.212014
unifiedWMWqPCR: the unified Wilcoxon-Mann-Whitney test for analyzing RT-qPCR data in R · Bioinform. 2014
Bioinformatics and computational biology › proteomics › phosphoproteomics
kinase activity inference
0.112011
The use of semiparametric mixed models to analyze PamChip® peptide array data: an application to an oncology experiment · Bioinform. 2011

Methods — techniques the papers use, named apart from their topics

quality score filtering · 0.2hidden markov model · 0.2wilcoxon-mann-whitney test · 0.2unified WMW test · 0.2semiparametric mixed model · 0.1
YearPublicationVenuePosition
2017 Using variant databases for variant prioritization and to detect erroneous genotype-phenotype associations
abstract
BACKGROUND: In the search for novel causal mutations, public and/or private variant databases are nearly always used to facilitate the search as they result in a massive reduction of putative variants in one step. Practically, variant filtering is often done by either using all variants from the variant database (called the absence-approach, i.e. it is assumed that disease-causing variants do not reside in variant databases) or by using the subset of variants with an allelic frequency > 1% (called the 1%-approach). We investigate the validity of these two approaches in terms of false negatives (the true disease-causing variant does not pass all filters) and false positives (a harmless mutation passes all filters and is erroneously retained in the list of putative disease-causing variants) and compare it with an novel approach which we named the quantile-based approach. This approach applies variable instead of static frequency thresholds and the calculation of these thresholds is based on prior knowledge of disease prevalence, inheritance models, database size and database characteristics. RESULTS: Based on real-life data, we demonstrate that the quantile-based approach outperforms the absence-approach in terms of false negatives. At the same time, this quantile-based approach deals more appropriately with the variable allele frequencies of disease-causing alleles in variant databases relative to the 1%-approach and as such allows a better control of the number of false positives. We also introduce an alternative application for variant database usage and the quantile-based approach. If disease-causing variants in variant databases deviate substantially from theoretical expectancies calculated with the quantile-based approach, their association between genotype and phenotype had to be reconsidered in 12 out of 13 cases. CONCLUSIONS: We developed a novel method and demonstrated that this so-called quantile-based approach is a highly suitable method for variant filtering. In addition, the quantile-based approach can also be used for variant flagging. For user friendliness, lookup tables and easy-to-use R calculators are provided.
Bart J. G. Broeckx, Luc Peelman, Jimmy Saunders, Dieter Deforce, Lieven Clement
BMC Bioinform.5
2015 VirVarSeq: a low-frequency virus variant detection pipeline for Illumina sequencing using adaptive base-calling accuracy filtering
abstract
MOTIVATION: In virology, massively parallel sequencing (MPS) opens many opportunities for studying viral quasi-species, e.g. in HIV-1- and HCV-infected patients. This is essential for understanding pathways to resistance, which can substantially improve treatment. Although MPS platforms allow in-depth characterization of sequence variation, their measurements still involve substantial technical noise. For Illumina sequencing, single base substitutions are the main error source and impede powerful assessment of low-frequency mutations. Fortunately, base calls are complemented with quality scores (Qs) that are useful for differentiating errors from the real low-frequency mutations. RESULTS: A variant calling tool, Q-cpileup, is proposed, which exploits the Qs of nucleotides in a filtering strategy to increase specificity. The tool is imbedded in an open-source pipeline, VirVarSeq, which allows variant calling starting from fastq files. Using both plasmid mixtures and clinical samples, we show that Q-cpileup is able to reduce the number of false-positive findings. The filtering strategy is adaptive and provides an optimized threshold for individual samples in each sequencing run. Additionally, linkage information is kept between single-nucleotide polymorphisms as variants are called at the codon level. This enables virologists to have an immediate biological interpretation of the reported variants with respect to their antiviral drug responses. A comparison with existing SNP caller tools reveals that calling variants at the codon level with Q-cpileup results in an outstanding sensitivity while maintaining a good specificity for variants with frequencies down to 0.5%. AVAILABILITY: The VirVarSeq is available, together with a user's guide and test data, at sourceforge: http://sourceforge.net/projects/virtools/?source=directory.
Bie M. P. Verbist, Kim Thys, Joke Reumers, Yves Wetzels, Koen Van der Borght, Willem Talloen, Jeroen Aerssens, Lieven Clement, Olivier Thas
Bioinform.8
2015 QQ-SNV: single nucleotide variant detection at low frequency by comparing the quality quantiles
abstract
BACKGROUND: Next generation sequencing enables studying heterogeneous populations of viral infections. When the sequencing is done at high coverage depth ("deep sequencing"), low frequency variants can be detected. Here we present QQ-SNV (http://sourceforge.net/projects/qqsnv), a logistic regression classifier model developed for the Illumina sequencing platforms that uses the quantiles of the quality scores, to distinguish true single nucleotide variants from sequencing errors based on the estimated SNV probability. To train the model, we created a dataset of an in silico mixture of five HIV-1 plasmids. Testing of our method in comparison to the existing methods LoFreq, ShoRAH, and V-Phaser 2 was performed on two HIV and four HCV plasmid mixture datasets and one influenza H1N1 clinical dataset. RESULTS: For default application of QQ-SNV, variants were called using a SNV probability cutoff of 0.5 (QQ-SNV(D)). To improve the sensitivity we used a SNV probability cutoff of 0.0001 (QQ-SNV(HS)). To also increase specificity, SNVs called were overruled when their frequency was below the 80(th) percentile calculated on the distribution of error frequencies (QQ-SNV(HS-P80)). When comparing QQ-SNV versus the other methods on the plasmid mixture test sets, QQ-SNV(D) performed similarly to the existing approaches. QQ-SNV(HS) was more sensitive on all test sets but with more false positives. QQ-SNV(HS-P80) was found to be the most accurate method over all test sets by balancing sensitivity and specificity. When applied to a paired-end HCV sequencing study, with lowest spiked-in true frequency of 0.5%, QQ-SNV(HS-P80) revealed a sensitivity of 100% (vs. 40-60% for the existing methods) and a specificity of 100% (vs. 98.0-99.7% for the existing methods). In addition, QQ-SNV required the least overall computation time to process the test sets. Finally, when testing on a clinical sample, four putative true variants with frequency below 0.5% were consistently detected by QQ-SNV(HS-P80) from different generations of Illumina sequencers. CONCLUSIONS: We developed and successfully evaluated a novel method, called QQ-SNV, for highly efficient single nucleotide variant calling on Illumina deep sequencing virology data.
Koen Van der Borght, Kim Thys, Yves Wetzels, Lieven Clement, Bie M. P. Verbist, Joke Reumers, Herman van Vlijmen, Jeroen Aerssens
BMC Bioinform.4
2015 ViVaMBC: estimating viral sequence variation in complex populations from illumina deep-sequencing data using model-based clustering
abstract
BACKGROUND: Deep-sequencing allows for an in-depth characterization of sequence variation in complex populations. However, technology associated errors may impede a powerful assessment of low-frequency mutations. Fortunately, base calls are complemented with quality scores which are derived from a quadruplet of intensities, one channel for each nucleotide type for Illumina sequencing. The highest intensity of the four channels determines the base that is called. Mismatch bases can often be corrected by the second best base, i.e. the base with the second highest intensity in the quadruplet. A virus variant model-based clustering method, ViVaMBC, is presented that explores quality scores and second best base calls for identifying and quantifying viral variants. ViVaMBC is optimized to call variants at the codon level (nucleotide triplets) which enables immediate biological interpretation of the variants with respect to their antiviral drug responses. RESULTS: Using mixtures of HCV plasmids we show that our method accurately estimates frequencies down to 0.5%. The estimates are unbiased when average coverages of 25,000 are reached. A comparison with the SNP-callers V-Phaser2, ShoRAH, and LoFreq shows that ViVaMBC has a superb sensitivity and specificity for variants with frequencies above 0.4%. Unlike the competitors, ViVaMBC reports a higher number of false-positive findings with frequencies below 0.4% which might partially originate from picking up artificial variants introduced by errors in the sample and library preparation step. CONCLUSIONS: ViVaMBC is the first method to call viral variants directly at the codon level. The strength of the approach lies in modeling the error probabilities based on the quality scores. Although the use of second best base calls appeared very promising in our data exploration phase, their utility was limited. They provided a slight increase in sensitivity, which however does not warrant the additional computational cost of running the offline base caller. Apparently a lot of information is already contained in the quality scores enabling the model based clustering procedure to adjust the majority of the sequencing errors. Overall the sensitivity of ViVaMBC is such that technical constraints like PCR errors start to form the bottleneck for low frequency variant detection.
Bie M. P. Verbist, Lieven Clement, Joke Reumers, Kim Thys, Alexander Vapirev, Willem Talloen, Yves Wetzels, Joris Meys, Jeroen Aerssens, Luc Bijnens, Olivier Thas
BMC Bioinform.2
2014 unifiedWMWqPCR: the unified Wilcoxon-Mann-Whitney test for analyzing RT-qPCR data in R
abstract
MOTIVATION: Recently, De Neve et al. proposed a modification of the Wilcoxon-Mann-Whitney (WMW) test for assessing differential expression based on RT-qPCR data. Their test, referred to as the unified WMW (uWMW) test, incorporates a robust and intuitive normalization and quantifies the probability that the expression from one treatment group exceeds the expression from another treatment group. However, no software package for this test was available yet. RESULTS: We have developed a Bioconductor package for analyzing RT-qPCR data with the uWMW test. The package also provides graphical tools for visualizing the effect sizes. AVAILABILITY AND IMPLEMENTATION: The unifiedWMWqPCR package and its user documentation can be obtained through Bioconductor.
Jan De Neve, Joris Meys, Jean-Pierre Ottoy, Lieven Clement, Olivier Thas
Bioinform.4
2014 Impact of variance components on reliability of absolute quantification using digital PCR
abstract
BACKGROUND: Digital polymerase chain reaction (dPCR) is an increasingly popular technology for detecting and quantifying target nucleic acids. Its advertised strength is high precision absolute quantification without needing reference curves. The standard data analytic approach follows a seemingly straightforward theoretical framework but ignores sources of variation in the data generating process. These stem from both technical and biological factors, where we distinguish features that are 1) hard-wired in the equipment, 2) user-dependent and 3) provided by manufacturers but may be adapted by the user. The impact of the corresponding variance components on the accuracy and precision of target concentration estimators presented in the literature is studied through simulation. RESULTS: We reveal how system-specific technical factors influence accuracy as well as precision of concentration estimates. We find that a well-chosen sample dilution level and modifiable settings such as the fluorescence cut-off for target copy detection have a substantial impact on reliability and can be adapted to the sample analysed in ways that matter. User-dependent technical variation, including pipette inaccuracy and specific sources of sample heterogeneity, leads to a steep increase in uncertainty of estimated concentrations. Users can discover this through replicate experiments and derived variance estimation. Finally, the detection performance can be improved by optimizing the fluorescence intensity cut point as suboptimal thresholds reduce the accuracy of concentration estimates considerably. CONCLUSIONS: Like any other technology, dPCR is subject to variation induced by natural perturbations, systematic settings as well as user-dependent protocols. Corresponding uncertainty may be controlled with an adapted experimental design. Our findings point to modifiable key sources of uncertainty that form an important starting point for the development of guidelines on dPCR design and data analysis with correct precision bounds. Besides clever choices of sample dilution levels, experiment-specific tuning of machine settings can greatly improve results. Well-chosen data-driven fluorescence intensity thresholds in particular result in major improvements in target presence detection. We call on manufacturers to provide sufficiently detailed output data that allows users to maximize the potential of the method in their setting and obtain high precision and accuracy for their experiments.
Bart K. M. Jacobs, Els Goetghebeur, Lieven Clement
BMC Bioinform.3
2012 Analysis of tiling array expression studies with flexible designs in Bioconductor (waveTiling
abstract
BACKGROUND: Existing statistical methods for tiling array transcriptome data either focus on transcript discovery in one biological or experimental condition or on the detection of differential expression between two conditions. Increasingly often, however, biologists are interested in time-course studies, studies with more than two conditions or even multiple-factor studies. As these studies are currently analyzed with the traditional microarray analysis techniques, they do not exploit the genome-wide nature of tiling array data to its full potential. RESULTS: We present an R Bioconductor package, waveTiling, which implements a wavelet-based model for analyzing transcriptome data and extends it towards more complex experimental designs. With waveTiling the user is able to discover (1) group-wise expressed regions, (2) differentially expressed regions between any two groups in single-factor studies and in (3) multifactorial designs. Moreover, for time-course experiments it is also possible to detect (4) linear time effects and (5) a circadian rhythm of transcripts. By considering the expression values of the individual tiling probes as a function of genomic position, effect regions can be detected regardless of existing annotation. Three case studies with different experimental set-ups illustrate the use and the flexibility of the model-based transcriptome analysis. CONCLUSIONS: The waveTiling package provides the user with a convenient tool for the analysis of tiling array trancriptome data for a multitude of experimental set-ups. Regardless of the study design, the probe-wise analysis allows for the detection of transcriptional effects in both exonic, intronic and intergenic regions, without prior consultation of existing annotation.
Kristof De Beuf, Peter Pipelers, Megan Andriankaja, Olivier Thas, Dirk Inzé, Ciprian M. Crainiceanu, Lieven Clement
BMC Bioinform.7
2012 Improved base-calling and quality scores for 454 sequencing based on a Hurdle Poisson model
abstract
BACKGROUND: 454 pyrosequencing is a commonly used massively parallel DNA sequencing technology with a wide variety of application fields such as epigenetics, metagenomics and transcriptomics. A well-known problem of this platform is its sensitivity to base-calling insertion and deletion errors, particularly in the presence of long homopolymers. In addition, the base-call quality scores are not informative with respect to whether an insertion or a deletion error is more likely. Surprisingly, not much effort has been devoted to the development of improved base-calling methods and more intuitive quality scores for this platform. RESULTS: We present HPCall, a 454 base-calling method based on a weighted Hurdle Poisson model. HPCall uses a probabilistic framework to call the homopolymer lengths in the sequence by modeling well-known 454 noise predictors. Base-calling quality is assessed based on estimated probabilities for each homopolymer length, which are easily transformed to useful quality scores. CONCLUSIONS: Using a reference data set of the Escherichia coli K-12 strain, we show that HPCall produces superior quality scores that are very informative towards possible insertion and deletion errors, while maintaining a base-calling accuracy that is better than the current one. Given the generality of the framework, HPCall has the potential to also adapt to other homopolymer-sensitive sequencing technologies.
Kristof De Beuf, Joachim M. De Schrijver, Olivier Thas, Wim Van Criekinge, Rafael A. Irizarry, Lieven Clement
BMC Bioinform.6
2011 The use of semiparametric mixed models to analyze PamChip® peptide array data: an application to an oncology experiment
abstract
MOTIVATION: Phosphorylation by protein kinases is a central theme in biological systems. Aberrant protein kinase activity has been implicated in a variety of human diseases (e.g. cancer). Therefore, modulation of kinase activity represents an attractive therapeutic approach for the treatment of human illnesses. Thus, identification of signature peptides is crucial for protein kinase targeting and can be achieved by using PamChip(®) microarray technology. We propose a flexible semiparametric mixed model for analyzing PamChip(®) data. This approach enables the estimation of the phosphorylation rate (Velocity) as a function of time together with pointwise confidence intervals. RESULTS: Using a publicly available dataset, we show that our model is capable of adequately fitting the kinase activity profiles and provides velocity estimates over time. Moreover, it allows to test for differences in the velocity of kinase inhibition between responding and non-responding cell lines. This can be done at individual time point as well as for the entire velocity profile. CONTACT: [email protected] SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.
Pushpike Jayantha Thilakarathne, Lieven Clement, Dan Lin 0004, Ziv Shkedy, Adetayo Kasim, Willem Talloen, Matthias Versele, Geert Verbeke
Bioinform.2