Demo Data from EDBT 2026 / reviewers in the wild / expert
Müller G. Urias
dblp:257/7258 · also Muller Urias
· DBLP profile ↗
4ranked-venue papers
0as first author
0since 2021 · last 2020
0000-0002-1017-7657ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 4Systems, architecture and hardware · 3Human-computer interaction and ubiquitous computing · 1Applied, interdisciplinary, general and emerging computing · 1
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
2 papers |
Motion planning and robot control · 61% Robot manipulation · 30% Robot navigation and mapping · 9% | |
| Interdisciplinary, comprehensive, and emerging computing
2 papers |
Medical and health informatics · 100% |
Topics — the 7 heaviest of 7, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Motion planning and robot control › manipulator control
force-constrained control |
0.4 | 1 | 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint Controller · ICRA 2020 |
Robotics › Motion planning and robot control
robot control |
0.4 | 1 | 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint Controller · ICRA 2020 |
Robotics › Robot manipulation › medical robotics › surgical robotics
teleoperated surgical robot |
0.4 | 1 | 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint Controller · ICRA 2020 |
Medical and health informatics
computer-assisted surgery |
0.4 | 1 | 2020 | Autonomously Navigating a Surgical Tool Inside the Eye by Learning from Demonstration · ICRA 2020 |
Medical and health informatics › ophthalmology
retinal surgery |
0.4 | 1 | 2020 | Autonomously Navigating a Surgical Tool Inside the Eye by Learning from Demonstration · ICRA 2020 |
Robotics › Robot navigation and mapping
mobile robot navigation |
0.1 | 1 | 2020 | Autonomously Navigating a Surgical Tool Inside the Eye by Learning from Demonstration · ICRA 2020 |
Medical and health informatics › surgical robotics
robot-assisted surgery |
0.1 | 1 | 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint Controller · ICRA 2020 |
Methods — techniques the papers use, named apart from their topics
visual servoing · 0.9learning from demonstration · 0.9force sensing · 0.9dual force constraint controller · 0.9deep network · 0.9
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2020 | Towards Bimanual Vein Cannulation: Preliminary Study of a Bimanual Robotic System With a Dual Force Constraint ControllerabstractRetinal vein cannulation is a promising approach for treating retinal vein occlusion that involves injecting medicine into the occluded vessel to dissolve the clot. The approach remains largely unexploited clinically due to surgeon limitations in detecting interaction forces between surgical tools and retinal tissue. In this paper, a dual force constraint controller for robot-assisted retinal surgery was presented to keep the tool-to-vessel forces and tool-to-sclera forces below prescribed thresholds. A cannulation tool and forceps with dual force-sensing capability were developed and used to measure force information fed into the robot controller, which was implemented on existing Steady Hand Eye Robot platforms. The robotic system facilitates retinal vein cannulation by allowing a user to grasp the target vessel with the forceps and then enter the vessel with the cannula. The system was evaluated on an eye phantom. The results showed that, while the eyeball was subjected to rotational disturbances, the proposed controller actuates the robotic manipulators to maintain the average tool-to-vessel force at 10.9 mN and 13.1 mN and the average tool-to-sclera force at 38.1 mN and 41.2 mN for the cannula and the forcpes, respectively. Such small tool-to-tissue forces are acceptable to avoid retinal tissue injury. Additionally, two clinicians participated in a preliminary user study of the bimanual cannulation demonstrating that the operation time and tool-to-tissue forces are significantly decreased when using the bimanual robotic system as compared to freehand performance. Changyan He, Emily Yang, Müller G. Urias, Yang Yang 0103, Peter Gehlbach, Iulian Iordachita |
ICRA | 4 |
| 2020 | Autonomously Navigating a Surgical Tool Inside the Eye by Learning from DemonstrationabstractA fundamental challenge in retinal surgery is safely navigating a surgical tool to a desired goal position on the retinal surface while avoiding damage to surrounding tissues, a procedure that typically requires tens-of-microns accuracy. In practice, the surgeon relies on depth-estimation skills to localize the tool-tip with respect to the retina in order to perform the tool-navigation task, which can be prone to human error. To alleviate such uncertainty, prior work has introduced ways to assist the surgeon by estimating the tooltip distance to the retina and providing haptic or auditory feedback. However, automating the tool-navigation task itself remains unsolved and largely unexplored. Such a capability, if reliably automated, could serve as a building block to streamline complex procedures and reduce the chance for tissue damage. Towards this end, we propose to automate the tool-navigation task by learning to mimic expert demonstrations of the task. Specifically, a deep network is trained to imitate expert trajectories toward various locations on the retina based on recorded visual servoing to a given goal specified by the user. The proposed autonomous navigation system is evaluated in simulation and in physical experiments using a silicone eye phantom. We show that the network can reliably navigate a needle surgical tool to various desired locations within 137 μm accuracy in physical experiments and 94 μm in simulation on average, and generalizes well to unseen situations such as in the presence of auxiliary surgical tools, variable eye backgrounds, and brightness conditions. Ji Woong Kim, Changyan He, Müller G. Urias, Peter Gehlbach, Gregory D. Hager, Iulian Iordachita, Marin Kobilarov |
ICRA | 3 |
| 2020 | An Optimized Tilt Mechanism for a New Steady-Hand Eye RobotabstractRobot-assisted vitreoretinal surgery can filter surgeons' hand tremors and provide safe, accurate tool manipulation. In this paper, we report the design, optimization, and evaluation of a novel tilt mechanism for a new Steady-Hand Eye Robot (SHER). The new tilt mechanism features a four-bar linkage design and has a compact structure. Its kinematic configuration is optimized to minimize the required linear range of motion (LRM) for implementing a virtual remote center-of-motion (V-RCM) while tilting a surgical tool. Due to the different optimization constraints for the robots at the left and right sides of the human head, two configurations of this tilt mechanism are proposed. Experimental results show that the optimized tilt mechanism requires a significantly smaller LRM (e.g. 5.08 mm along Z direction and 8.77 mm along Y direction for left side robot) as compared to the slider-crank tilt mechanism used in the previous SHER (32.39 mm along Z direction and 21.10 mm along Y direction). The feasibility of the proposed tilt mechanism is verified in a mock bilateral robot-assisted vitreoretinal surgery. The ergonomically acceptable robot postures needed to access the surgical field is also determined. Jiahao Wu 0002, Gang Li 0018, Müller G. Urias, Niravkumar A. Patel, Yun-Hui Liu 0001, Peter Gehlbach, Russell H. Taylor, Iulian Iordachita |
IROS | 3 |
| 2019 | Towards securing the sclera against patient involuntary head movement in robotic retinal surgeryabstractRetinal surgery involves manipulating very delicate tissues within the confined area of eyeball. In such demanding practices, patient involuntary head movement might abruptly raise tool-to-eyeball interaction forces which would be detrimental to eye. This study is aimed at implementing different force control strategies and evaluating how they contribute to attaining sclera force safety while patient head drift is present. To simulate patient head movement, a piezoelectric-actuated linear stage is used to produce random motions in a single direction in random time intervals. Having an eye phantom attached to the linear stage then an experienced eye surgeon is asked to manipulate the eye and repeat a mock surgical task both with and without the assist of the Steady-Hand Eye Robot. For the freehand case, warning sounds were provided to the surgeon as auditory feedback to alert him about excessive slclra forces. For the robot-assisted experiments two variants of an adaptive sclera force control and a virtual fixture method were deployed to see how they can maintain eye safety under head drift circumstances. The results indicate that the developed robot control strategies are able to compensate for head drift and keep the sclera forces under safe levels as well as the free hand operation. Müller G. Urias, Niravkumar A. Patel, Changyan He, Russell H. Taylor, Peter Gehlbach, Iulian Iordachita |
RO-MAN | 2 |