Manuel Viermetz
dblp:260/5805
· DBLP profile ↗
7ranked-venue papers
2as first author
6since 2021 · last 2024
0000-0002-7332-1900ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Applied, interdisciplinary, general and emerging computing · 7 · 2 first-author · 6 since 2021
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2024 | Robust Sample Information Retrieval in Dark-Field Computed Tomography With a Vibrating Talbot-Lau InterferometerabstractX-ray computed tomography (CT) is a crucial tool for non-invasive medical diagnosis that uses differences in materials' attenuation coefficients to generate contrast and provide 3D information. Grating-based dark-field-contrast X-ray imaging is an innovative technique that utilizes small-angle scattering to generate additional co-registered images with additional microstructural information. While it is already possible to perform human chest dark-field radiography, it is assumed that its diagnostic value increases when performed in a tomographic setup. However, the susceptibility of Talbot-Lau interferometers to mechanical vibrations coupled with a need to minimize data acquisition times has hindered its application in clinical routines and the combination of X-ray dark-field imaging and large field-of-view (FOV) tomography in the past. In this work, we propose a processing pipeline to address this issue in a human-sized clinical dark-field CT prototype. We present the corrective measures that are applied in the employed processing and reconstruction algorithms to mitigate the effects of vibrations and deformations of the interferometer gratings. This is achieved by identifying spatially and temporally variable vibrations in air reference scans. By translating the found correlations to the sample scan, we can identify and mitigate relevant fluctuation modes for scans with arbitrary sample sizes. This approach effectively eliminates the requirement for sample-free detector area, while still distinctly separating fluctuation and sample information. As a result, samples of arbitrary dimensions can be reconstructed without being affected by vibration artifacts. To demonstrate the viability of the technique for human-scale objects, we present reconstructions of an anthropomorphic thorax phantom. Jakob Haeusele, Clemens Schmid, Manuel Viermetz, Nikolai Gustschin, Tobias Lasser, Thomas Köhler 0003, Franz Pfeiffer |
IEEE Trans. Medical Imaging | 3 |
| 2023 | Advanced Phase-Retrieval for Stepping-Free X-Ray Dark-Field Computed TomographyabstractGrating-based phase- and dark-field-contrast X-ray imaging is a novel technology that aims to extend conventional attenuation-based X-ray imaging by unlocking two additional contrast modalities. The so called phase-contrast and dark-field channels provide enhanced soft tissue contrast and additional microstructural information. Accessing this additional information comes at the expense of a more intricate measurement setup and necessitates sophisticated data processing. A big challenge for translating grating-based dark-field computed tomography to medical applications lies in minimizing the data acquisition time. While a continuously moving detector is ideal, it prohibits conventional phase stepping techniques that require multiple projections under the same angle with different grating positions. One solution to this problem is the so-called sliding window processing approach that is compatible with continuous data acquisition. However, conventional sliding window techniques lead to crosstalk-artifacts between the three image channels, if the projection of the sample moves too fast on the detector within a processing window. In this work we introduce a new interpretation of the phase retrieval problem for continuous acquisitions as a demodulation problem. In this interpretation, we identify the origin of the crosstalk-artifacts as partially overlapping modulation side bands. Furthermore, we present three algorithmic extensions that improve the conventional sliding-window-based phase retrieval and mitigate crosstalk-artifacts. The presented algorithms are tested in a simulation study and on experimental data from a human-scale dark-field CT prototype. In both cases they achieve a substantial reduction of the occurring crosstalk-artifacts. Jakob Haeusele, Clemens Schmid, Manuel Viermetz, Nikolai Gustschin, Tobias Lasser, Thomas Köhler 0003, Franz Pfeiffer |
IEEE Trans. Medical Imaging | 3 |
| 2023 | Modeling Vibrations of a Tiled Talbot-Lau Interferometer on a Clinical CTabstractX-ray computed tomography (CT) is an invaluable imaging technique for non-invasive medical diagnosis. However, for soft tissue in the human body the difference in attenuation is inherently small. Grating-based X-ray phase-contrast is a relatively novel imaging method which detects additional interaction mechanisms between photons and matter, namely refraction and small-angle scattering, to generate additional images with different contrast. The experimental setup involves a Talbot-Lau interferometer whose susceptibility to mechanical vibrations hindered acquisition schemes suitable for clinical routine in the past. We present a processing pipeline to identify spatially and temporally variable fluctuations occurring in an interferometer installed on a continuously rotating clinical CT gantry. The correlations of the vibrations in the modular grating setup are exploited to identify a small number of relevant fluctuation modes, allowing for a sample reconstruction free of vibration artifacts. Clemens Schmid, Manuel Viermetz, Nikolai Gustschin, Wolfgang Noichl, Jakob Haeusele, Tobias Lasser, Thomas Köhler 0003, Franz Pfeiffer |
IEEE Trans. Medical Imaging | 2 |
| 2023 | Initial Characterization of Dark-Field CT on a Clinical GantryabstractX-ray computed tomography (CT) is an important non-destructive imaging technique, particularly in clinical diagnostics. Even with the latest innovations like dual-energy and photon-counting CT, the image contrast is solely generated from attenuation in the tissue. An extension - fully compatible with these novelties - is dark-field CT, which retrieves an additional, so-called dark-field contrast. Unlike the attenuation channel, the dark-field channel is sensitive to tissue microstructure and porosity below the resolution of the imaging system, which allows additional insights into the health of the lung tissue or the structure of calcifications. The potential clinical value has been demonstrated in several preclinical studies and recently also in radiography patient studies. Just recently the first dark-field CT for the human body was established at the Technical University of Munich and in this paper, we discuss the performance of this prototype. We evaluate the interferometer components and the imposed challenges that the integration into the CT gantry brings by comparing the results to simulations and measurements at a laboratory setup. The influence of the clinical X-ray source on the Talbot-Lau interferometer and the impact of vibrations, which are immanent on the clinical CT gantry, are analyzed in detail to reveal their characteristic frequencies and origin. A beam hardening correction is introduced as an important step to adapt to the poly-chromatic spectrum and make quantitative dark-field imaging possible. We close with an analysis of the image resolution and the applied patient dose, and conclude that the performance is sufficient to suggest initial patient studies using the presented dark-field CT system. Manuel Viermetz, Nikolai Gustschin, Clemens Schmid, Jakob Haeusele, Bernhard Gleich, Bernhard C. Renger, Thomas Köhler 0003, Franz Pfeiffer |
IEEE Trans. Medical Imaging | 1 |
| 2023 | Technical Design Considerations of a Human-Scale Talbot-Lau Interferometer for Dark-Field CTabstractComputed tomography (CT) as an important clinical diagnostics method can profit from extension with dark-field imaging, as it is currently restricted to X-rays' attenuation contrast only. Dark-field imaging allows access to more tissue properties, such as micro-structural texture or porosity. The up-scaling process to clinical scale is complex because several design constraints must be considered. The two most important ones are that the finest grating is limited by current manufacturing technology to a [Formula: see text] period and that the interferometer should fit into the CT gantry with minimal modifications only. In this work we discuss why an inverse interferometer and a triangular G1 profile are advantageous and make a compact and sensitive interferometer implementation feasible. Our evaluation of the triangular grating profile reveals a deviation in the interference pattern compared to standard grating profiles, which must be considered in the subsequent data processing. An analysis of the grating orientation demonstrates that currently only a vertical layout can be combined with cylindrical bending of the gratings. We also provide an in-depth discussion, including a new simulation approach, of the impact of the extended X-ray source spot which can lead to large performance loss and present supporting experimental results. This analysis reveals a vastly increased sensitivity to geometry and grating period deviations, which must be considered early in the system design process. Manuel Viermetz, Nikolai Gustschin, Clemens Schmid, Jakob Haeusele, Peter B. Noël, Roland Proksa, Stefan Löscher, Thomas Köhler 0003, Franz Pfeiffer |
IEEE Trans. Medical Imaging | 1 |
| 2021 | Direct Differentiation of Pathological Changes in the Human Lung Parenchyma With Grating-Based Spectral X-ray Dark-Field RadiographyabstractDiagnostic lung imaging is often associated with high radiation dose and lacks sensitivity, especially for diagnosing early stages of structural lung diseases. Therefore, diagnostic imaging methods are required which provide sound diagnosis of lung diseases with a high sensitivity as well as low patient dose. In small animal experiments, the sensitivity of grating-based X-ray dark-field imaging to structural changes in the lung tissue was demonstrated. The energy-dependence of the X-ray dark-field signal of lung tissue is a function of its microstructure and not yet known. Furthermore, conventional X-ray dark-field imaging is not capable of differentiating different types of pathological changes, such as fibrosis and emphysema. Here we demonstrate the potential diagnostic power of grating-based X-ray dark-field in combination with spectral imaging in human chest radiography for the direct differentiation of lung diseases. We investigated the energy-dependent linear diffusion coefficient of simulated lung tissue with different diseases in wave-propagation simulations and validated the results with analytical calculations. Additionally, we modeled spectral X-ray dark-field chest radiography scans to exploit these differences in energy-dependency. The results demonstrate the potential to directly differentiate structural changes in the human lung. Consequently, grating-based spectral X-ray dark-field imaging potentially contributes to the differential diagnosis of structural lung diseases at a clinically relevant dose level. Kirsten Alexandra Taphorn, Korbinian Mechlem, Thorsten Sellerer, Fabio De Marco, Manuel Viermetz, Franz Pfeiffer, Daniela Pfeiffer, Julia Herzen |
IEEE Trans. Medical Imaging | 5 |
| 2020 | Spectral Differential Phase Contrast X-Ray RadiographyabstractWe investigate the combination of two emerging X-ray imaging technologies, namely spectral imaging and differential phase contrast imaging. By acquiring spatially and temporally registered images with several different X-ray spectra, spectral imaging can exploit differences in the energy-dependent attenuation to generate material selective images. Differential phase contrast imaging uses an entirely different contrast generation mechanism: The phase shift that an X-ray wave exhibits when traversing an object. As both methods can determine the (projected) electron density, we propose a novel material decomposition algorithm that uses the spectral and the phase contrast information simultaneously. Numerical experiments show that the combination of these two imaging techniques benefits from the strengths of the individual methods while the weaknesses are mitigated: Quantitatively accurate basis material images are obtained and the noise level is strongly reduced, compared to conventional spectral X-ray imaging. Korbinian Mechlem, Thorsten Sellerer, Manuel Viermetz, Julia Herzen, Franz Pfeiffer |
IEEE Trans. Medical Imaging | 3 |