2022 A Pneumatic MR-conditional Guidewire Delivery Mechanism with Decoupled Actuations for Endovascular Intervention
abstract
Percutaneous coronary intervention (PCI) involves the delivery of a flexible submillimeter guidewire and existing x- ray based approaches impose significant ironing radiation. The use of magnetic resonance imaging (MRI) for intraoperative guidance has the advantages of not only being safe but also having high positioning accuracy and excellent tissue contrast. This paper develops a pneumatically driven MR-conditional delivery mechanism for the ease of manipulation of the guidewire in vivo. It incorporates newly developed rotary pneumatic step motors and a pneumatic slip ring for actuation and decoupling of translational and rotational motions. An effective clamping mechanism for the locking and releasing of the guidewire is also incorporated. The proposed pneumatic slip ring mechanism decouples six gas lines, where four are used to supply a pneumatic step motor for translational motion and two for the clamping mechanism. High friction sil sleeve is used to hold the guidewire firmly. The rotary pneumatic motor has excellent sealing and stability, providing an output torque of 15.75 Nm/MPa. Experiments show that the average error of translational motion is 0.37 mm. Real-time MRI-guided endovascular intervention is performed in a vascular phantom with pulsatile flows to validate its potential clinical use. The imaging artifact test under MRI shows no noticeable distortion and the loss of Signal-to-Noise Ratio (SNR) is less than 2%.
Shaoping Huang, Chuqian Lou, Lian Xuan, Hongyan Gao, Anzhu Gao, Guang-Zhong Yang
IROS2
2021 An MR Safe Rotary Encoder Based on Eccentric Sheave and FBG Sensors
abstract
MRI-guided robotic systems are emerging platforms for minimally invasive intervention because of high positioning accuracy and excellent tissue contrast. MR safe encoders are critical components for closed-loop robotic control. This paper develops an MR safe absolute rotary encoder based on eccentric sheave and FBG sensors. The eccentric sheave transforms the rotational motion of the shaft to the bending deflection of the beam on which FBG sensors are integrated. A model is built by establishing the relationship of the kinematics of the sheave, the mechanical properties of the beam with unknown length, and the strain model of two Fiber Bragg Grating (FBG) sensors. A Pseudo-Rigid Body (PRB) 3R model is used to solve a set of constrained equations for accurate rotary encoding. A prototype is built to calibrate the parameters and validate the accuracy of the encoder and its MR compatibility. Results show that the maximum angular error is 1.6°, and the RMS error is 0.46°. MRI shows that no noticeable artifacts are observed, and the Signal to Noise Ratio (SNR) is not affected. The results demonstrate the potential of the proposed method for it to be integrated with MR safe robots with easy fabrication, compact structures, and continuous measurement.
Shaoping Huang, Anzhu Gao, Zicong Wu, Chuqian Lou, Guang-Zhong Yang
ICRA4
2021 Robotic Electrospinning Actuated by Non-Circular Joint Continuum Manipulator for Endoluminal Therapy
abstract
Electrospinning has exhibited excellent benefits to treat the trauma for tissue engineering due to its produced micro/nano fibrous structure. It can effectively adhere to the tissue surface for long-term continuous therapy. This paper develops a robotic electrospinning platform for endoluminal therapy. The platform consists of a continuum manipulator, the electrospinning device, and the actuation unit. The continuum manipulator has two bending sections to facilitate the steering of the tip needle for a controllable spinning direction. Non-circular joint profile is carefully designed to enable a constant length of the centreline of a continuum manipulator for stable fluid transmission inside it. Experiments are performed on a bronchus phantom, and the steering ability and bending limitation in each direction are also investigated. The endoluminal electrospinning is also fulfilled by a trajectory following and points targeting experiments. The effective adhesive area of the produced fibre is also illustrated. The proposed robotic electrospinning shows its feasibility to precisely spread more therapeutic drug to construct fibrous structure for potential endoluminal treatments.
Zicong Wu, Chuqian Lou, Zhu Jin, Shaoping Huang, Mirko Kovac, Anzhu Gao, Guang-Zhong Yang
ICRA2