Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.

Geoffrey J. M. Parker

dblp:29/3895 · also Geoff J. M. Parker · DBLP profile ↗
← Back
8ranked-venue papers
1as first author
1since 2021 · last 2024
0000-0003-2934-2234ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 7 · 1 first-author · 1 since 2021Graphics, computer vision, multimedia, augmented reality and games · 5Artificial intelligence and machine learning · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › neuroimaging
diffusion MRI
0.112007
Exploiting peak anisotropy for tracking through complex structures · ICCV 2007
Medical and health informatics › neuroimaging › diffusion MRI analysis
fiber orientation estimation
0.112007
Exploiting peak anisotropy for tracking through complex structures · ICCV 2007
Medical and health informatics › neuroimaging › diffusion MRI analysis
fiber tracking
0.112007
Exploiting peak anisotropy for tracking through complex structures · ICCV 2007
Medical and health informatics
neuroimaging
0.112007
Exploiting peak anisotropy for tracking through complex structures · ICCV 2007

Methods — techniques the papers use, named apart from their topics

q-ball imaging · 0.1bootstrap experiment · 0.1bingham distribution · 0.1Persistent Angular Structure MRI · 0.1
YearPublicationVenuePosition
2024 An efficient semi-supervised quality control system trained using physics-based MRI-artefact generators and adversarial training
abstract
Large medical imaging data sets are becoming increasingly available. A common challenge in these data sets is to ensure that each sample meets minimum quality requirements devoid of significant artefacts. Despite a wide range of existing automatic methods having been developed to identify imperfections and artefacts in medical imaging, they mostly rely on data-hungry methods. In particular, the scarcity of artefact-containing scans available for training has been a major obstacle in the development and implementation of machine learning in clinical research. To tackle this problem, we propose a novel framework having four main components: (1) a set of artefact generators inspired by magnetic resonance physics to corrupt brain MRI scans and augment a training dataset, (2) a set of abstract and engineered features to represent images compactly, (3) a feature selection process that depends on the class of artefact to improve classification performance, and (4) a set of Support Vector Machine (SVM) classifiers trained to identify artefacts. Our novel contributions are threefold: first, we use the novel physics-based artefact generators to generate synthetic brain MRI scans with controlled artefacts as a data augmentation technique. This will avoid the labour-intensive collection and labelling process of scans with rare artefacts. Second, we propose a large pool of abstract and engineered image features developed to identify 9 different artefacts for structural MRI. Finally, we use an artefact-based feature selection block that, for each class of artefacts, finds the set of features that provide the best classification performance. We performed validation experiments on a large data set of scans with artificially-generated artefacts, and in a multiple sclerosis clinical trial where real artefacts were identified by experts, showing that the proposed pipeline outperforms traditional methods. In particular, our data augmentation increases performance by up to 12.5 percentage points on the accuracy, F1, F2, precision and recall. At the same time, the computation cost of our pipeline remains low - less than a second to process a single scan - with the potential for real-time deployment. Our artefact simulators obtained using adversarial learning enable the training of a quality control system for brain MRI that otherwise would have required a much larger number of scans in both supervised and unsupervised settings. We believe that systems for quality control will enable a wide range of high-throughput clinical applications based on the use of automatic image-processing pipelines.
Daniele Ravì, Frederik Barkhof, Daniel C. Alexander, Lemuel Puglisi, Geoffrey J. M. Parker, Arman Eshaghi
Medical Image Anal.5
2010 Cross-Visit Tumor Sub-segmentation and Registration with Outlier Rejection for Dynamic Contrast-Enhanced MRI Time Series Data
Giovanni A. Buonaccorsi, C. J. Rose, J. P. B. O'Connor, Caleb Roberts, Yvonne Watson, Alan Jackson, Gordon C. Jayson, Geoffrey J. M. Parker
MICCAI (3)8
2009 Using the Model-Based Residual Bootstrap to Quantify Uncertainty in Fiber Orientations From Q -Ball Analysis
abstract
Bootstrapping of repeated diffusion-weighted image datasets enables nonparametric quantification of the uncertainty in the inferred fiber orientation. The wild bootstrap and the residual bootstrap are model-based residual resampling methods which use a single dataset. Previously, the wild bootstrap method has been presented as an alternative to conventional bootstrapping for diffusion tensor imaging. Here we present a study of an implementation of model-based residual bootstrapping using q -ball analysis and compare the outputs with conventional bootstrapping. We show that model-based residual bootstrap q-ball generates results that closely match the output of the conventional bootstrap. Both the residual and conventional bootstrap of multifiber methods can be used to estimate the probability of different numbers of fiber populations existing in different brain tissues. Also, we have shown that these methods can be used to provide input for probabilistic tractography, avoiding existing limitations associated with data calibration and model selection.
Hamied A. Haroon, David M. Morris, Karl V. Embleton, Daniel C. Alexander, Geoffrey J. M. Parker
IEEE Trans. Medical Imaging5
2007 Exploiting peak anisotropy for tracking through complex structures
abstract
This work shows that multi-fibre reconstruction techniques, such as Persistent Angular Structure (PAS) MRI or QBall Imaging, provide much more information than just discrete fibre orientations, which is all that previous tractography algorithms exploit from them. We show that the shapes of the peaks of the functions output by multiple-fibre reconstruction algorithms reflect the underlying distribution of fibres. Furthermore, we show how to exploit this extra information to improve Probabilistic Index of Connectivity (PICo) tractography. The method uses the Bingham distribution to model the uncertainty in fibre-orientation estimates obtained from peaks in the PAS or QBall Orientation Distribution Function (ODF). The Bingham model captures anisotropy in the uncertainty, allowing the method to track through fanning and bending structures, which previous methods do not recover reliably. We devise a new calibration procedure to construct a mapping from peak shape to Bingham parameters. We test the accuracy of the calibration using a bootstrap experiment. Finally, we show that exploiting the peak shape in this way can provide improved PICo tractography results.
Kiran K. Seunarine, Philip A. Cook, Matt G. Hall, Karl V. Embleton, Geoffrey J. M. Parker, Daniel C. Alexander
ICCV5
2007 Quantifying Heterogeneity in Dynamic Contrast-Enhanced MRI Parameter Maps
C. J. Rose, Samantha J. Mills, J. P. B. O'Connor, Giovanni A. Buonaccorsi, Caleb Roberts, Yvonne Watson, Brandon J. Whitcher, Gordon C. Jayson, Alan Jackson, Geoffrey J. M. Parker
MICCAI (2)10
2005 Tracer Kinetic Model-Driven Registration for Dynamic Contrast Enhanced MRI Time Series
Giovanni A. Buonaccorsi, Caleb Roberts, Sue Cheung, Yvonne Watson, Karen Davies, Alan Jackson, Gordon C. Jayson, Geoffrey J. M. Parker
MICCAI8
2004 Improved Regional Analysis of Oxygen-Enhanced Lung MR Imaging Using Image Registration
Josephine H. Naish, Geoffrey J. M. Parker, Paul C. Beatty, Alan Jackson, John C. Waterton, Simon S. Young, Christopher J. Taylor 0001
MICCAI (1)2
2002 Estimating Distributed Anatomical Brain Connectivity Using Fast Marching Methods and Diffusion Tensor Imaging
abstract
A method is presented for determining paths of anatomical connection between regions of the brain using magnetic resonance diffusion tensor information. Level set theory, applied using fast marching methods, is used to generate three-dimensional time of arrival maps, from which connection paths between brain regions may be identified. The method is demonstrated in the normal brain and it is shown that major white matter tracts may be elucidated and that multiple connections and tract branching are allowed. Maps of connectivity between brain regions are also determined. Four options are described for estimating the degree of connectivity between regions.
Geoffrey J. M. Parker, Claudia A. M. Gandini Wheeler-Kingshott, Gareth J. Barker
IEEE Trans. Medical Imaging1