Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Myunghee Kim

dblp:32/4372 · DBLP profile ↗
← Back
6ranked-venue papers
3as first author
0since 2021 · last 2020
0000-0001-8965-6206ORCID · corroborated

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 4 · 1 first-authorSystems, architecture and hardware · 3 · 1 first-authorApplied, interdisciplinary, general and emerging computing · 2 · 2 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
4 papers
Robot manipulation · 29% Legged, aerial and field robots · 26% Optimization for machine learning · 26%
Human-computer interaction and pervasive computing
4 papers
Human-robot interaction · 56% Health and well-being technologies · 33% Accessibility and assistive technology · 6%

Topics — the 9 heaviest of 10, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Legged, aerial and field robots › legged robots
bipedal walking
0.422018
Once-Per-Step Control of Ankle Push-Off Work Improves Balance in a Three-Dimensional Simulation of Bipedal Walking · IEEE Trans. Robotics 2017
An Ankle-Foot Prosthesis Emulator With Control of Plantarflexion and Inversion-Eversion Torque · IEEE Trans. Robotics 2018
Machine learning › Optimization for machine learning › model-based optimization
bayesian optimization
0.412019
Bayesian Optimization of Soft Exosuits Using a Metabolic Estimator Stopping Process · ICRA 2019
Human-robot interaction › wearable robot
exosuit control
0.412019
Bayesian Optimization of Soft Exosuits Using a Metabolic Estimator Stopping Process · ICRA 2019
Human-robot interaction
wearable robot
0.412019
Bayesian Optimization of Soft Exosuits Using a Metabolic Estimator Stopping Process · ICRA 2019
Robotics › Motion planning and robot control › locomotion control
balance control
0.312017
Once-Per-Step Control of Ankle Push-Off Work Improves Balance in a Three-Dimensional Simulation of Bipedal Walking · IEEE Trans. Robotics 2017
Robotics › Robot manipulation › wearable robotics › prosthetic device
ankle-foot prosthesis
0.212015
An ankle-foot prosthesis emulator with control of plantarflexion and inversion-eversion torque · ICRA 2015
Robotics › Robot manipulation › wearable robotics
prosthetic device
0.212015
An ankle-foot prosthesis emulator with control of plantarflexion and inversion-eversion torque · ICRA 2015
Accessibility and assistive technology › assistive technology
robotic prosthesis
0.112017
Once-Per-Step Control of Ankle Push-Off Work Improves Balance in a Three-Dimensional Simulation of Bipedal Walking · IEEE Trans. Robotics 2017
Haptics and multimodal interaction
haptic rendering
0.112015
An ankle-foot prosthesis emulator with control of plantarflexion and inversion-eversion torque · ICRA 2015

Methods — techniques the papers use, named apart from their topics

closed-loop torque control · 1.1optimal stopping · 0.8kalman filter · 0.8bayesian optimization · 0.8strain gauge sensing · 0.7series elasticity · 0.73d walking simulation · 0.6strain gages · 0.4state-feedback control · 0.3state feedback control · 0.3
YearPublicationVenuePosition
2020 The personalization of stiffness for an ankle-foot prosthesis emulator using Human-in-the-loop optimization
abstract
Evidence suggests that the metabolic cost associated with the locomotive activity of walking is dependent upon ankle stiffness. This stiffness can be a control parameter in an ankle-foot prosthesis. Considering unique physical interaction between each individual with below-knee amputation and robotic ankle-foot prosthesis, individually tuned stiffness in a robotic ankle-foot prosthesis may improve assistance benefits. This personalization can be accomplished through human-in-the-loop (HIL) Bayesian optimization (BO). Here, we conducted a pilot study to identify personalized ankle- foot prosthesis stiffness using the HIL BO to minimize the cost of walking, shown by metabolic cost. We used an improved versatile ankle-foot prosthesis emulator, which enabled to test controllers with a wide range of stiffness conditions. Two participants with simulated amputation reduced their cost of walking under the condition of personalized (optimized) stiffness by 6% and 5%, respectively. This result suggests that personalized stiffness may improve assistance benefit.
Tin-Chun Wen, Michael Jacobson, Xingyuan Zhou, Hyun-Joon Chung, Myunghee Kim
IROS5
2019 Bayesian Optimization of Soft Exosuits Using a Metabolic Estimator Stopping Process
abstract
Recent human-in-the-loop (HIL) optimization studies using wearable devices have shown an improved average metabolic reduction by optimizing a small number of control parameters during short-duration walking experiments. However, the slow metabolic dynamics, high measurement noise, and experimental time constraints create challenges for increasing the number of control parameters to be optimized. Prior work applying gradient descent and Bayesian optimization to this problem have decoupled metabolic estimation and control parameter selection using fixed estimation intervals, which imposes a hard limit on the number of parameter evaluations possible in a given time budget. In this work, we take a different approach that couples estimation and parameter selection, allowing the algorithm to spend less time on refining the metabolic estimates for parameters that are unlikely to improve performance over the best observed values. Our approach uses a Kalman filter-based metabolic estimator to formulate an optimal stopping problem during the data acquisition step of standard Bayesian optimization. Performance was analyzed in numerical simulations and in pilot human subject testing with two subjects that involved optimizing six control parameters of a single-joint exosuit and four parameters of a multi-joint exosuit.
Myunghee Kim, Charles Liu, Jinsoo Kim 0006, Adham Meguid, Conor J. Walsh, Scott Kuindersma
ICRA1
2018 An Ankle-Foot Prosthesis Emulator With Control of Plantarflexion and Inversion-Eversion Torque
abstract
Ankle inversion-eversion compliance is an important feature of conventional prosthetic feet, and control of inversion, or roll, in active prostheses could improve balance for people with amputation. We designed a tethered ankle-foot prosthesis with two independently actuated toes that are coordinated to provide plantarflexion and inversion-eversion torques. A Bowden cable tether provides series elasticity. The prosthesis is simple and lightweight, with a mass of 0.72kg. Strain gauges on the toes measure torque with less than 1% root mean squared (RMS) error. Benchtop tests demonstrated a step response rise time of less than 33 ms, peak torques of 250 N·m in plantarflexion and ±30 N·m in inversion-eversion, and peak power above 3 kW. The phase-limited closed-loop torque bandwidth is 20 Hz with a chirp from 10 to 90 N·m in plantarflexion, and 24 Hz with a chirp from -20 to 20 N·m in inversion. The system has low sensitivity to toe position disturbances at frequencies of up to 18 Hz. Walking trials with an amputee subject demonstrated RMS torque tracking errors of less than 5.1 N·m in plantarflexion and less than 1.5 N·m in inversion-eversion. These properties make the platform suitable for testing inversion-related prosthesis features and controllers in experiments with humans.
Myunghee Kim, Tianjian Chen, Tianyao Chen, Steven H. Collins
IEEE Trans. Robotics1
2017 Once-Per-Step Control of Ankle Push-Off Work Improves Balance in a Three-Dimensional Simulation of Bipedal Walking
abstract
Individuals with lower limb amputation have a high fall risk, which could be partially due to a lack of stabilizing control in conventional prostheses. Inspired by walking robots, we hypothesized that modulating prosthetic ankle push-off could help improve amputee balance. We developed a three-dimensional walking model, found limit cycles at two speeds, and designed state-feedback controllers that made once-per-step adjustments to ankle push-off work, fore-aft and medial-lateral foot placement, and ankle roll resistance. To assess balance, we applied increasing levels of random changes in ground height and lateral impulses until the model fell down within 100 steps. Although foot placement is known to be important for balance, we found that push-off control was at least twice as effective at recovering from both disturbances at both speeds. Push-off work affected both fore-aft and mediolateral motions, leading to good controllability, and was particularly well suited to recovery from steps up or down. Our results suggest that discrete control of ankle push-off may be more important than previously thought, and may guide the design of robotic prostheses that improve balance.
Myunghee Kim, Steven H. Collins
IEEE Trans. Robotics1
2015 An ankle-foot prosthesis emulator with control of plantarflexion and inversion-eversion torque
abstract
Ankle inversion-eversion compliance is an important feature of conventional prosthetic feet, and control of inversion, or roll, in robotic prostheses could improve balance for people with amputation. We designed a tethered ankle-foot prosthesis with two independently-actuated toes that are coordinated to provide plantarflexion and inversion-eversion torques. This configuration allows a simple lightweight structure with a total mass of 0.72 kg. Strain gages on the toes measure torque with less than 2.7% RMS error, while compliance in the Bowden cable tether provides series elasticity. Benchtop tests demonstrated a 90% rise time of less than 33 ms and peak torques of 180 N·m in plantarflexion and ±30 N·m in inversion-eversion. The phase-limited closedloop torque bandwidth is 20 Hz with a 90 N·m amplitude chirp in plantarflexion, and 24 Hz with a 20 N·m amplitude chirp in inversion-eversion. The system has low sensitivity to toe position disturbances at frequencies of up to 18 Hz. Walking trials with five values of constant inversion-eversion torque demonstrated RMS torque tracking errors of less than 3.7% in plantarflexion and less than 5.9% in inversion-eversion. These properties make the platform suitable for haptic rendering of virtual devices in experiments with humans, which may reveal strategies for improving balance or allow controlled comparisons of conventional prosthesis features. A similar morphology may be effective for autonomous devices.
Steven H. Collins, Myunghee Kim, Tianjian Chen, Tianyao Chen
ICRA2
1992 Generation of Extended Bilingual Statistical Reports
L. Iordanskaja, Myunghee Kim, Richard I. Kittredge, Benoit Lavoie, Alain Polguère
COLING2