Demo Data from EDBT 2026 / reviewers in the wild / expert
Gulnur Avci
dblp:320/8420
· DBLP profile ↗
2ranked-venue papers
0as first author
2since 2021 · last 2024
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Computer networks · 2 · 2 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Computer networks
1 paper |
Physical-layer communications · 100% |
Topics — the 3 heaviest of 3, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Physical-layer communications › channel modeling › channel characterization › channel measurement
millimeter-wave channel measurement |
0.8 | 1 | 2024 | Outdoor-to-Indoor 28 GHz Wireless Measurements in Manhattan: Path Loss, Environmental Effects, and 90% Coverage · IEEE/ACM Trans. Netw. 2024 |
Physical-layer communications › radio propagation
millimeter-wave propagation |
0.8 | 1 | 2024 | Outdoor-to-Indoor 28 GHz Wireless Measurements in Manhattan: Path Loss, Environmental Effects, and 90% Coverage · IEEE/ACM Trans. Netw. 2024 |
Physical-layer communications › channel modeling
path loss modeling |
0.8 | 1 | 2024 | Outdoor-to-Indoor 28 GHz Wireless Measurements in Manhattan: Path Loss, Environmental Effects, and 90% Coverage · IEEE/ACM Trans. Netw. 2024 |
Methods — techniques the papers use, named apart from their topics
measurement campaign · 0.8
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2024 | Outdoor-to-Indoor 28 GHz Wireless Measurements in Manhattan: Path Loss, Environmental Effects, and 90% CoverageabstractOutdoor-to-indoor signal propagation poses significant challenges to millimeter-wave link budgets. To gain insight into outdoor-to-indoor millimeter-wave at 28GHz, we conducted an extensive measurement campaign consisting of over 2,200 link measurements in West Harlem, New York City, covering seven highly diverse buildings. A path loss model constructed over all measured links shows an average of 30dB excess loss over free space at distances beyond 50m. We find the type of glass to be the dominant factor in outdoor-to-indoor loss, with 20dB observed difference between grouped scenarios with low-and high-loss glass. Other factors such as the presence of scaffolding, tree foliage, or elevated subway tracks, as well as difference in floor height are also found to have a 5–10dB impact. We show that for urban buildings with high-loss glass, outdoor-to-indoor downlink capacity up to 400Mb/s is supported for 90% of indoor customer premises equipment by a base station up to 40m away. For buildings with low-loss glass, such as our case study covering multiple classrooms of a public school, downlink capacity over 2.8/1.4Gb/s is possible from a base station 57/133m away within line-of-sight. We expect these results to help inform the planning of millimeter-wave networks targeting outdoor-to-indoor deployments in dense urban environments, as well as provide insight into the development of scheduling and beam management algorithms. Manav Kohli, Abhishek Adhikari, Gulnur Avci, Sienna Brent, Aditya Dash, Jared Moser, Sabbir Hossain, Igor Kadota, Carson Garland, Shivan Mukherjee, Rodolfo Feick, Dmitry Chizhik, Jinfeng Du, Reinaldo A. Valenzuela, Gil Zussman |
IEEE/ACM Trans. Netw. | 3 |
| 2022 | Outdoor-to-indoor 28 GHz wireless measurements in manhattan: path loss, location impacts, and 90% coverageabstractOutdoor-to-indoor (OtI) signal propagation further challenges link budgets at millimeter-wave (mmWave). To gain insight into OtI mmWave at 28 GHz, we conducted an extensive measurement campaign consisting of over 2,000 link measurements in West Harlem, New York City, covering seven highly diverse buildings. A path loss model constructed over all links shows an average of 30 dB excess loss over free space at distances beyond 50 m. We find the type of glass to be the dominant factor in OtI loss, with 20 dB observed difference between clustered scenarios with low- and high-loss glass. Other factors, such as difference in floor height, are found to have an impact between 5--10 dB. We show that for urban buildings with high-loss glass, OtI data rates up to 400 Mb/s are supported for 90% of indoor users by a base station (BS) up to 49 m away. For buildings with low-loss glass, such as our case study covering multiple classrooms of a public school, data rates over 2.8/1.4 Gb/s are possible from a BS 68/175 m away when a line-of-sight path is available. We expect these results to be useful for the deployment of OtI mmWave networks in dense urban environments and the development of scheduling and beam management algorithms. Manav Kohli, Abhishek Adhikari, Gulnur Avci, Sienna Brent, Jared Moser, Sabbir Hossain, Aditya Dash, Igor Kadota, Rodolfo Feick, Dmitry Chizhik, Jinfeng Du, Reinaldo A. Valenzuela, Gil Zussman |
MobiHoc | 3 |