EDBT 2026 Demo / reviewers in the wild / expert
Emanuele Nicotra
dblp:324/6248
· DBLP profile ↗
4ranked-venue papers
1as first author
4since 2021 · last 2025
0009-0008-4083-5666ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 4 · 1 first-author · 4 since 2021Systems, architecture and hardware · 4 · 1 first-author · 4 since 2021
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2025 | Compliance Control with Dynamic and Self-Sensing Hydraulic Artificial Muscles for Wearable Assistive DevicesabstractWhile wearable robots that utilize intrinsically soft materials for actuation offer enhanced safety and biological compatibility, the challenges of sensing and control significantly affect their performance. The control problem in such systems is inherently complex, and the inclusion of 'softness' introduces additional nonlinearities, hysteresis, and uncertainties. Furthermore, the effectiveness of control strategies is highly dependent on sensor selection and integration, which presents its own challenges. Most robotic systems require separate sensors for control purposes. In this study, a new sensing and control scheme are introduced for soft wearable robots, leveraging the intrinsic soft-sensing capability of fluidic filament actuators without adding computational complexity. This method enables simultaneous sensing and actuation with$\mathbf{9 6 \%}$position accuracy, even under physical disturbances. This approach is demonstrated with a soft assistive device for elbow flexion/extension, achieving 70.5% tracking accuracy and a 0.09s response delay to human intention, ensuring the system provides minimal resistance when assistance is not needed, while delivering the required support when necessary. Bibhu Sharma, Emanuele Nicotra, James Davies 0002, Chi Cong Nguyen, Phuoc Thien Phan, Adrienne Ji, Kefan Zhu, Trung Dung Ngo, Hung Manh La, Van Anh Ho, Nigel H. Lovell, Thanh Nho Do |
ICRA | 2 |
| 2024 | A Soft Micro-Robotic Catheter for Aneurysm Treatment: A Novel Design and Enhanced Euler-Bernoulli Model with Cross-Section OptimizationabstractAneurysms, balloon-like bulges in blood vessels, present a significant health risk due to their potential to rupture, leading to life-threatening internal bleeding. Current treatments often involve delivering embolic materials or metal coils to fill these bulges, occluding them from the pressure of blood flow. However, clinical micro-catheters that deploy embolic materials used today face limitations, primarily their rigidity and the lack of active control over the bending tip of the catheter. This paper introduces a new soft micro-robotics catheter, with diameter of only 0.8 mm, equipped with a hollow channel. With this new design, the new device can induce bending motions at its tip for active steerability to reach desired aneurysm targets and then perform the delivery of embolic materials and tools. To enhance the control and precise navigation during procedures, a robust mathematical model and image processing techniques are also introduced and validated. Experiments are also performed to characterise and validate the model’s accuracy and the steerability and navigation capabilities of the new micro-catheter. Emanuele Nicotra, Chi Cong Nguyen, James Davies 0002, Phuoc Thien Phan, Trung Thien Hoang, Bibhu Sharma, Adrienne Ji, Kefan Zhu, Trung Dung Ngo, Van Anh Ho, Hung Manh La, Nigel H. Lovell, Thanh Nho Do |
ICRA | 1 |
| 2022 | Hydraulically Actuated Soft Tubular GripperabstractThere is an increasing interest in soft robotic grippers as they exhibit an ability to grip objects of differing shapes, sizes, textures, and even deformable materials, all of which present a difficult challenge to traditional rigid grippers. An ideal soft gripper would exhibit universal gripping with high gripping force and consists of low-cost materials with simple fabrication processes. This paper investigates the development of a strong and scalable hydraulic soft tubular gripper (HSTG) using facile fabrication method and low-cost materials. The HSTG which consists of a single long hydraulically actuated artificial muscle, soft 3D printed element, and commercial weaving yarn can expand and contract its orifice to grasp objects using a miniature hydraulic syringe. Grasping experiments show that the new HSTG can successfully grasp convex, nonconvex, and flat objects as well as the ones with cavity. The soft gripper uniquely exhibits high normal contact force at minimal pressure and energy use due to the nature of its working principle. A 26 g HSTG can produce at least 40 N of gripping force, can hold at least 88 N in external gripping mode (~346 times of its weight), 0.34 N in internal mode, and 1.74 N in suction gripping mode. The design and mechanical properties of its components can be fine-tuned to produce tailored performance for different grasping tasks. James Davies 0002, Phuoc Thien Phan, Diana Huang, Trung Thien Hoang, Harrison Low, Mai Thanh Thai, Chi Cong Nguyen, Emanuele Nicotra, Nigel H. Lovell, Thanh Nho Do |
ICRA | 8 |
| 2022 | Bidirectional Soft Robotic Catheter for Arrhythmia TreatmentabstractHeart rhythm disorders are becoming increasingly prevalent with population aging. Atrial fibrillation ablation (AFA) is a procedure used to treat an irregular heart rhythm (arrhythmia) that starts in the heart's upper chambers. The AFA works by scarring or destroying heart tissue to disrupt aberrant conduction pathways causing the arrhythmia. In hospital cardiac units, a flexible catheter with integrated metal electrode is currently used for the AFA procedure. Despite advances, existing cardiac catheter tips are driven by cable mechanisms which are associated with high nonlinear hysteresis and force loss. In addition, they are also limited to rigid components which require multiple actuators to control the bending tip to reach the complex anatomical corners of the heart. This paper introduces a new soft hydraulic catheter that can achieve bidirectional bending motion via a single soft artificial muscle. The new catheter is also equipped with a portable handle as an ergonomic control interface. To validate the design concept, various prototypes are fabricated and tested including bending angles and generated force capability. Mathematical models for the bending arm are also developed and experimentally validated. The new soft catheter will enable rapid and precise manipulation to reach any target within the cardiac chambers, offering more rapid and focused ablation therapy to improve patient outcomes. Chi Cong Nguyen, Timotius Teh, Mai Thanh Thai, Phuoc Thien Phan, Trung Thien Hoang, Harrison Low, James Davies 0002, Emanuele Nicotra, Nigel H. Lovell, Thanh Nho Do |
ICRA | 8 |