Demo Data from EDBT 2026 / reviewers in the wild / expert
Hyeonwoo Kee
dblp:324/6506
· DBLP profile ↗
2ranked-venue papers
0as first author
2since 2021 · last 2023
0000-0002-9362-3498ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2 · 2 since 2021Systems, architecture and hardware · 2 · 2 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Artificial intelligence
1 paper |
Robot manipulation · 100% | |
| Interdisciplinary, comprehensive, and emerging computing
1 paper |
Medical and health informatics · 100% |
Topics — the 3 heaviest of 3, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Robotics › Robot manipulation › actuation
magnetic actuation |
0.6 | 1 | 2022 | Magnetically Steerable Asymmetric Magnetized Soft Continuum Robot (AMSCR) for Minimally Invasive Surgery · ICRA 2022 |
Robotics › Robot manipulation › soft robotics
soft continuum robot |
0.6 | 1 | 2022 | Magnetically Steerable Asymmetric Magnetized Soft Continuum Robot (AMSCR) for Minimally Invasive Surgery · ICRA 2022 |
Medical and health informatics › surgical robotics
minimally invasive surgery |
0.2 | 1 | 2022 | Magnetically Steerable Asymmetric Magnetized Soft Continuum Robot (AMSCR) for Minimally Invasive Surgery · ICRA 2022 |
Methods — techniques the papers use, named apart from their topics
finite element simulation · 1.1phantom experiments · 0.6phantom experiment · 0.6
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2023 | Active Capsule System for Multiple Therapeutic Patch Delivery: Preclinical EvaluationabstractRecently, active research has been conducted on the therapeutic functions of capsule endoscopes. Here, we propose an active capsule system that captures images of the interior of the gastrointestinal tract (GI) and actively delivers therapeutic patches. The active capsule system mainly comprises therapeutic patches, an active capsule equipped with a camera, and a robot-assisted magnetic actuator. The active capsule moves inside the GI tract via a magnetic actuator using a robot, captures pictures of the GI tract in actual time, and performs hemostatic treatment by delivering therapeutic patches to the target lesions. First, the fundamental performance of the active capsule system was verified via a hemostatic performance test of the therapeutic patch, patch contamination prevention test of the active capsule, and basic actuation test of the capsule. Second, multiple therapeutic patches were delivered to the gastric surface in an ex vivo test using an active capsule system. Finally, as a preclinical test, it was confirmed that the GI tract examination and the therapeutic patches delivery were possible using the active capsule system through an animal test using a porcine. Consequently, the proposed active capsule system represents a new paradigm for capsule endoscopy with multiple therapeutic patch delivery capabilities. Manh Cuong Hoang, Jayoung Kim 0001, Hyeonwoo Kee, Seungun Yang, Jong-Oh Park, Sukho Park |
IROS | 5 |
| 2022 | Magnetically Steerable Asymmetric Magnetized Soft Continuum Robot (AMSCR) for Minimally Invasive SurgeryabstractSoft continuum robots have been widely used as guide wires or catheters for minimally invasive surgery (MIS), and the miniaturization and dexterity are very important characteristics of soft continuum robots. As a representative actuation method for soft continuum robots, the steering using an external magnetic field has been actively studied. The magnetic actuation method is appropriate for the miniaturization of soft continuum robots but shows limitations in implementing high dexterity. To achieve miniaturization and high dexterity, this paper proposes a magnetically steerable asymmetric magnetized soft continuum robot (AMSCR). The proposed AMSCR includes an active steering part (ASP) of a thin PDMS cylinder in which NdFeB powder is uniformly dispersed and magnetized asymmetrically to the longitudinal direction. Therefore, compared to the conventional symmetric magnetized soft continuum robot (SMSCR), the proposed AMSCR has a larger steering range and high dexterity. Through various experiments, simulations, and phantom experiments using the proposed AMSCR, we analyzed its characteristics, verified its enhanced steering range, and demonstrated the applicability to the surgeries requiring high dexterity in the eye or cerebrovascular. Hyoryong Lee, Hyunchul Choi, Sunwoo Sohn, Hyeonwoo Kee, Joohack Lee, Gyungrae Cha, Sukho Park |
ICRA | 5 |