Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Christopher Wai Sam Cheng

dblp:34/1187 · DBLP profile ↗
← Back
4ranked-venue papers
0as first author
0since 2021 · last 2006
—ORCID · unresolved

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 3Graphics, computer vision, multimedia, augmented reality and games · 3Systems, architecture and hardware · 1Applied, interdisciplinary, general and emerging computing · 1

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Motion planning and robot control · 87% 3D vision · 13%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 4 heaviest of 4, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Motion planning and robot control
motion planning
0.112005
Ultrasound Guided Robotic System for Transperineal Biopsy of the Prostate · ICRA 2005
Robotics › Motion planning and robot control › path planning › collision-free path planning
needle path planning
0.112005
Ultrasound Guided Robotic System for Transperineal Biopsy of the Prostate · ICRA 2005
Medical and health informatics
medical robotics
0.112005
Ultrasound Guided Robotic System for Transperineal Biopsy of the Prostate · ICRA 2005
Computer vision › 3D vision
3d reconstruction
0.012005
Ultrasound Guided Robotic System for Transperineal Biopsy of the Prostate · ICRA 2005

Methods — techniques the papers use, named apart from their topics

transrectal ultrasound · 0.13d modeling · 0.1
YearPublicationVenuePosition
2006 Evaluation on Similarity Measures of a Surface-to-Image Registration Technique for Ultrasound Images
Wei Shao 0001, Ruoyun Wu, Keck Voon Ling, Choon Hua Thng, Henry Sun Sien Ho, Christopher Wai Sam Cheng, Wan Sing Ng
MICCAI (2)6
2005 Ultrasound Guided Robotic System for Transperineal Biopsy of the Prostate
abstract
We present a prototype of a robotic system for accurate and consistent insertion of a percutaneous biopsy needle into the prostate. The robot manipulates a transrectal ultrasound (TRUS) probe to collect a series of 2 dimensional (2D) images of the prostate, which are later used to create a 3D computer model of the organ. The urologist defines the needle’s entry point at the perineal wall and the biopsy points within the 3D model following a biopsy protocol or otherwise. The robotic system then calculates the required trajectory of the needle. The path of the needle going into the prostate can also be simulated with the 3D model before the actual insertion. Being satisfied with the predicted outcome, the urologist configures the robot accordingly and manually pushes the mechanically guided needle into the patient to take the biopsy. Cadaveric and human trials have validated the robot’s needle placement error to be less than 2.5mm. Our future work includes the integration of a cancer predictive modality into the system to increase the cancer detection rate. The robotic system could also be modified to accurately place foreign bodies into the prostate, which could improve therapeutic procedures such as Brachytherapy.
Louis Phee, John Yuen, Chee Fatt Chan, Henry Sun Sien Ho, Choon Hua Thng, Christopher Wai Sam Cheng, Wan Sing Ng
ICRA7
2002 A HIFU robot for transperineal treatment of prostate cancer
abstract
Prostate cancer accounts for 29% of all cancers diagnosed in males in the United States. Present therapeutic procedures for prostate cancer are either invasive or minimally invasive. However, recent advances in technology (e.g. High Intensity Focused Ultrasound (HIFU)) allow the possibility of also non-invasive therapeutic procedures. This paper describes localizing the position of the prostate using an ultrasound probe. With this information, the robot can accurately manipulate a non-invasive therapeutic tool, such as HIFU, to an area of interest in the prostate via the transperineal route.
Ng Choong Kheng, Wan Sing Ng, Louis Phee, Christopher Wai Sam Cheng
ICARCV4
2002 A hifu robot for transperineal treatment of prostate cancer
abstract
Prostate cancer accounts for 29% of all cancers diagnosed in males in the United States. Resent therapeutic procedures for prostate cancer are either invasive or minimally invasive. However, recent advances in technology (e.g. High intensity Focused Ultrasound (HIFU)) allow the possibility of also non-invasive therapeutic procedures. This paper describes localizing the position of the prostate using an ultrasound probe. With this jnformation, the robot can accurately manipulate a non-invasive therapeutic tool, such as HlFU, to an area of interest in the prostate via the transperineal route.
Ng Choong Kheng, Wan Sing Ng, Louis Phee, Christopher Wai Sam Cheng
ICARCV4