EDBT 2026 Demo / reviewers in the wild / expert
Jordan P. Amadio
dblp:348/4211
· DBLP profile ↗
8ranked-venue papers
0as first author
8since 2021 · last 2025
0000-0003-3468-2620ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 7 · 7 since 2021Systems, architecture and hardware · 7 · 7 since 2021Graphics, computer vision, multimedia, augmented reality and games · 1 · 1 since 2021Applied, interdisciplinary, general and emerging computing · 1 · 1 since 2021
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2025 | Towards Evaluating the User Comfort and Experience of a Novel Steerable Drilling Robotic System in Pedicle Screw Fixation Procedures: A User StudyabstractAiming at developing a safe, intuitive, and collaborative steerable drilling robotic system for pedicle screw fixation procedures, in this paper, we leverage our recently developed steerable drilling robotic framework, and developed a collaborative drilling mode to control this system. In this control mode, first a user positions a concentric tube steerable drilling robot (CT-SDR) in the workspace and aligns it based on a preplanned trajectory. Next, the CT-SDR is directly controlled by the user through an admittance mode to perform a drilling procedure and creating a J-shape tunnel. To evaluate the user comfort and intuitiveness of the drilling procedure using this system and the proposed control interface, we performed a user study with 11 subjects, who had no prior experience in using this system. The results of this study were analyzed using various qualitative and quantitative metrics. Susheela Sharma, Frigyes Samuel Racz, Sarah Go, Siddhartha Kapuria, Omid Rezayof, Jordan P. Amadio, Mohsen Khadem, José del R. Millán, Farshid Alambeigi |
ICRA | 6 |
| 2025 | Towards Design and Development of a Concentric Tube Steerable Drilling Robot for Creating S-shape Tunnels for Pelvic Fixation ProceduresabstractCurrent pelvic fixation techniques rely on rigid drilling tools, which inherently constrain the placement of rigid medical screws in the complex anatomy of pelvis. These constraints prevent medical screws from following anatomically optimal pathways and force clinicians to fixate screws in linear trajectories. This suboptimal approach, combined with the unnatural placement of the excessively long screws, lead to complications such as screw misplacement, extended surgery times, and increased radiation exposure due to repeated X-ray images taken ensure to safety of procedure. To address these challenges, in this paper, we present the design and development of a unique 4-degree-of-freedom (DoF) pelvic concentric tube steerable drilling robot (pelvic CT-SDR). The pelvic CT-SDR is capable of creating long S-shaped drilling trajectories that follow the natural curvatures of the pelvic anatomy. The performance of the pelvic CT-SDR was thoroughly evaluated through several S-shape drilling experiments in simulated bone phantoms. Yash Kulkarni, Susheela Sharma, Sarah Go, Jordan P. Amadio, Mohsen Khadem, Farshid Alambeigi |
IROS | 4 |
| 2025 | Augmented Bridge Spinal Fixation: A New Concept for Addressing Pedicle Screw Pullout via a Steerable Drilling Robot and Flexible Pedicle ScrewsabstractTo address the screw loosening and pullout limitations of rigid pedicle screws in spinal fixation procedures, and to leverage our recently developed Concentric Tube Steerable Drilling Robot (CT-SDR) and Flexible Pedicle Screw (FPS), in this paper, we introduce the concept of Augmented Bridge Spinal Fixation (AB-SF). In this concept, two connecting J-shape tunnels are first drilled through pedicles of vertebra using the CT-SDR. Next, two FPSs are passed through this tunnel and bone cement is then injected through the cannulated region of the FPS to form an augmented bridge between two pedicles and reinforce strength of the fixated spine. To experimentally analyze and study the feasibility of AB-SF technique, we first used our robotic system (i.e., a CT-SDR integrated with a robotic arm) to create two different fixation scenarios in which two J-shape tunnels, forming a bridge, were drilled at different depth of a vertebral phantom. Next, we implanted two FPSs within the drilled tunnels and then successfully simulated the bone cement augmentation process. Yash Kulkarni, Susheela Sharma, Omid Rezayof, Siddhartha Kapuria, Jordan P. Amadio, Mohsen Khadem, Maryam Tilton, Farshid Alambeigi |
IROS | 5 |
| 2025 | Design and Integration of an Optical Frequency Domain Reflectometry (OFDR) Sensor with a Flexible Pedicle Screw for Biomechanical EvaluationabstractSpinal fixation procedures rely on pedicle screws to stabilize the vertebral column, but conventional rigid pedicle screws (RPS) face challenges such as misplacement, pullout, and loosening, particularly in patients with low bone mineral density (BMD). To overcome these limitations, we recently proposed a flexible pedicle screw (FPS) inserted inside a J-shape trajectory drilled by a steerable drilling robot. Towards biomechanical evaluation of our proposed FPS for spinal fixation procedures, in this paper, we introduce the design, integration, calibration, and evaluation of an optical frequency domain reflectometry (OFDR) strain sensor into an FPS. This sensor-integrated FPS (Si-FPS) provides real-time strain and shape-sensing information, facilitating improved implant functionality assessment and optimization. To thoroughly evaluate the Si-FPS, we first additively manufacture a special FPS and integrate a OFDR shape sensing assembly within its structure. We then assess shape sensing performance of this sensorized FPS using static and dynamic FPS insertion experiments. Yash Kulkarni, Mobina Tavangarifard, Jordan P. Amadio, Farshid Alambeigi |
IROS | 3 |
| 2025 | S3D: A Spatial Steerable Surgical Drilling Framework for Robotic Spinal Fixation ProceduresabstractIn this paper, we introduce S3D: A Spatial Steerable Surgical Drilling Framework for Robotic Spinal Fixation Procedures. S3D is designed to enable realistic steerable drilling while accounting for the anatomical constraints associated with vertebral access in spinal fixation (SF) procedures. To achieve this, we first enhanced our previously designed concentric tube Steerable Drilling Robot (CT-SDR) to facilitate steerable drilling across all vertebral levels of the spinal column. Additionally, we propose a four-Phase calibration, registration, and navigation procedure to perform realistic SF procedures on a spine holder phantom by integrating the CT-SDR with a seven-degree-of-freedom robotic manipulator. The functionality of this framework is validated through planar and out-of-plane steerable drilling experiments in vertebral phantoms. Daniyal Maroufi, Yash Kulkarni, Omid Rezayof, Susheela Sharma, Vaibhav Goggela, Jordan P. Amadio, Mohsen Khadem, Farshid Alambeigi |
IROS | 7 |
| 2024 | Spatial Spinal Fixation: A Transformative Approach Using a Unique Robot-Assisted Steerable Drilling System and Flexible Pedicle ScrewabstractSpinal fixation procedures are currently limited by the rigidity of the existing instruments and pedicle screws leading to fixation failures and rigid pedicle screw pull out. Leveraging our recently developed Concentric Tube Steerable Drilling Robot (CT-SDR) in integration with a robotic manipulator, to address the aforementioned issue, here we introduce the transformative concept of Spatial Spinal Fixation (SSF) using a unique Flexible Pedicle Screw (FPS). The proposed SSF procedure enables planar and out-of-plane placement of the FPS throughout the full volume of the vertebral body. In other words, not only does our fixation system provide the option of drilling in-plane and out-of-plane trajectories, it also enables implanting the FPS inside linear (represented by an I-shape) and/or non-linear (represented by J-shape) trajectories. To thoroughly evaluate the functionality of our proposed robotic system and the SSF procedure, we have performed various experiments by drilling different I-J and J-J drilling trajectory pairs into our custom-designed L3 vertebral phantoms and analyzed the accuracy of the procedure using various metrics. Susheela Sharma, Yash Kulkarni, Sarah Go, Jeff Bonyun, Jordan P. Amadio, Maryam Tilton, Mohsen Khadem, Farshid Alambeigi |
IROS | 5 |
| 2024 | A Patient-Specific Framework for Autonomous Spinal Fixation via a Steerable Drilling Robot
Susheela Sharma, Sarah Go, Zeynep Yakay, Yash Kulkarni, Siddhartha Kapuria, Jordan P. Amadio, Reza Rajebi, Mohsen Khadem, Nassir Navab, Farshid Alambeigi |
MICCAI (6) | 6 |
| 2023 | A Novel Concentric Tube Steerable Drilling Robot for Minimally Invasive Treatment of Spinal Tumors Using Cavity and U-shape Drilling TechniquesabstractIn this paper, we present the design, fabrication, and evaluation of a novel flexible, yet structurally strong, Concentric Tube Steerable Drilling Robot (CT-SDR) to improve minimally invasive treatment of spinal tumors. Inspired by concentric tube robots, the proposed two degree-of-freedom (DoF) CT-SDR, for the first time, not only allows a surgeon to intuitively and quickly drill smooth planar and out-of-plane J- and U- shape curved trajectories, but it also, enables drilling cavities through a hard tissue in a minimally invasive fashion. We successfully evaluated the performance and efficacy of the proposed CT-SDR in drilling various planar and out-of-plane J-shape branch, U-shape, and cavity drilling scenarios on simulated bone materials. Susheela Sharma, Ji Hwan Park, Jordan P. Amadio, Mohsen Khadem, Farshid Alambeigi |
ICRA | 3 |