Lena Maier-Hein

dblp:35/3435 · DBLP profile ↗
← Back
57ranked-venue papers
10as first author
29since 2021 · last 2026
0000-0003-4910-9368ORCID · verified

Domains — the database's venue-derived domains; a paper can count in several

Applied, interdisciplinary, general and emerging computing · 49 · 9 first-author · 25 since 2021Graphics, computer vision, multimedia, augmented reality and games · 26 · 5 first-author · 12 since 2021Artificial intelligence and machine learning · 8 · 1 first-author · 4 since 2021Human-computer interaction and ubiquitous computing · 1
YearPublicationVenuePosition
2026 Comparative validation of surgical phase recognition, instrument keypoint estimation, and instrument instance segmentation in endoscopy: Results of the PhaKIR 2024 challenge
abstract
Reliable recognition and localization of surgical instruments in endoscopic video recordings are foundational for a wide range of applications in computer- and robot-assisted minimally invasive surgery (RAMIS), including surgical training, skill assessment, and autonomous assistance. However, robust performance under real-world conditions remains a significant challenge. Incorporating surgical context - such as the current procedural phase - has emerged as a promising strategy to improve robustness and interpretability. To address these challenges, we organized the Surgical Procedure Phase, Keypoint, and Instrument Recognition (PhaKIR) sub-challenge as part of the Endoscopic Vision (EndoVis) challenge at MICCAI 2024. We introduced a novel, multi-center dataset comprising thirteen full-length laparoscopic cholecystectomy videos collected from three distinct medical institutions, with unified annotations for three interrelated tasks: surgical phase recognition, instrument keypoint estimation, and instrument instance segmentation. Unlike existing datasets, ours enables joint investigation of instrument localization and procedural context within the same data while supporting the integration of temporal information across entire procedures. We report results and findings in accordance with the BIAS guidelines for biomedical image analysis challenges. The PhaKIR sub-challenge advances the field by providing a unique benchmark for developing temporally aware, context-driven methods in RAMIS and offers a high-quality resource to support future research in surgical scene understanding.
Tobias Rueckert, David Rauber, Raphaela Maerkl, Leonard Klausmann, Suemeyye R. Yildiran, Max Gutbrod, Danilo Weber Nunes, Alvaro Fernandez Moreno, Imanol Luengo, Danail Stoyanov, Nicolas Toussaint, Enki Cho, Hyeon Bae Kim, Oh Sung Choo, Ka Young Kim, Seong Tae Kim 0001, Gonçalo Arantes, Kehan Song, Junchen Xiong, Tingyi Lin, Shunsuke Kikuchi, Hiroki Matsuzaki, Atsushi Kouno, João Renato Ribeiro Manesco, João Paulo Papa, Tae-Min Choi, Tae Kyeong Jeong, Oluwatosin Alabi, Tom Vercauteren, Runzhi Wu, Mengya Xu, An Wang 0007, Long Bai 0008, Hongliang Ren 0001, Amine Yamlahi, Jakob Hennighausen, Lena Maier-Hein, Satoshi Kondo, Satoshi Kasai, Kousuke Hirasawa, Shu Yang 0004, Yihui Wang 0002, Hao Chen 0011, Santiago Rodríguez, Nicolás Aparicio, Leonardo Manrique, Juan Camilo Lyons, Olivia Hosie, Nicolás Ayobi, Pablo Andrés Arbeláez, Yiping Li 0002, Yasmina Alkhalil, Sahar Nasirihaghighi, Stefanie Speidel, Daniel Rueckert, Hubertus Feußner, Dirk Wilhelm, Christoph Palm
Medical Image Anal.40
2025 Smarter Self-distillation: Optimizing the Teacher for Surgical Video Applications
Amine Yamlahi, Piotr Kalinowski, Patrick Godau, Rayan Younis, Martin Wagner 0001, Beat P. Müller-Stich, Lena Maier-Hein
MICCAI (9)7
2025 Including AI in diffusion-weighted breast MRI has potential to increase reader confidence and reduce workload
abstract
OBJECTIVES: Breast diffusion-weighted imaging (DWI) has shown potential as a standalone imaging technique for certain indications, eg, supplemental screening of women with dense breasts. This study evaluates an artificial intelligence (AI)-powered computer-aided diagnosis (CAD) system for clinical interpretation and workload reduction in breast DWI. MATERIALS AND METHODS: This retrospective IRB-approved study included: n = 824 examinations for model development (2017-2020) and n = 235 for evaluation (01/2021-06/2021). Readings were performed by three readers using either the AI-CAD or manual readings. BI-RADS-like (Breast Imaging Reporting and Data System) classification was based on DWI. Histopathology served as ground truth. The model was nnDetection-based, trained using 5-fold cross-validation and ensembling. Statistical significance was determined using McNemar's test. Inter-rater agreement was calculated using Cohen's kappa. Model performance was calculated using the area under the receiver operating curve (AUC). RESULTS: The AI-augmented approach significantly reduced BI-RADS-like 3 calls in breast DWI by 29% (P =.019) and increased interrater agreement (0.57 ± 0.10 vs 0.49 ± 0.11), while preserving diagnostic accuracy. Two of the three readers detected more malignant lesions (63/69 vs 59/69 and 64/69 vs 62/69) with the AI-CAD. The AI model achieved an AUC of 0.78 (95% CI: [0.72, 0.85]; P <.001), which increased for women at screening age to 0.82 (95% CI: [0.73, 0.90]; P <.001), indicating a potential for workload reduction of 20.9% at 96% sensitivity. DISCUSSION AND CONCLUSION: Breast DWI might benefit from AI support. In our study, AI showed potential for reduction of BI-RADS-like 3 calls and increase of inter-rater agreement. However, given the limited study size, further research is needed.
Dimitrios Bounias, Lina Simons, Michael Baumgartner 0001, Chris Ehring, Peter Neher, Lorenz A. Kapsner, Balint Kovacs, Ralf Floca, Paul F. Jaeger, Jessica Eberle, Dominique Hadler, Frederik B. Laun, Sabine Ohlmeyer, Lena Maier-Hein, Michael Uder, Evelyn Wenkel, Klaus H. Maier-Hein, Sebastian Bickelhaupt
J. Am. Medical Informatics Assoc.14
2025 Application-driven validation of posteriors in inverse problems
abstract
Current deep learning-based solutions for image analysis tasks are commonly incapable of handling problems to which multiple different plausible solutions exist. In response, posterior-based methods such as conditional Diffusion Models and Invertible Neural Networks have emerged; however, their translation is hampered by a lack of research on adequate validation. In other words, the way progress is measured often does not reflect the needs of the driving practical application. Closing this gap in the literature, we present the first systematic framework for the application-driven validation of posterior-based methods in inverse problems. As a methodological novelty, it adopts key principles from the field of object detection validation, which has a long history of addressing the question of how to locate and match multiple object instances in an image. Treating modes as instances enables us to perform mode-centric validation, using well-interpretable metrics from the application perspective. We demonstrate the value of our framework through instantiations for a synthetic toy example and two medical vision use cases: pose estimation in surgery and imaging-based quantification of functional tissue parameters for diagnostics. Our framework offers key advantages over common approaches to posterior validation in all three examples and could thus revolutionize performance assessment in inverse problems.
Tim Adler, Jan-Hinrich Nölke, Annika Reinke, Minu Tizabi, Sebastian Gruber 0001, Dasha Trofimova, Lynton Ardizzone, Paul F. Jaeger, Florian Buettner 0001, Ullrich Köthe, Lena Maier-Hein
Medical Image Anal.11
2025 An objective comparison of methods for augmented reality in laparoscopic liver resection by preoperative-to-intraoperative image fusion from the MICCAI2022 challenge
abstract
Augmented reality for laparoscopic liver resection is a visualisation mode that allows a surgeon to localise tumours and vessels embedded within the liver by projecting them on top of a laparoscopic image. Preoperative 3D models extracted from Computed Tomography (CT) or Magnetic Resonance (MR) imaging data are registered to the intraoperative laparoscopic images during this process. Regarding 3D-2D fusion, most algorithms use anatomical landmarks to guide registration, such as the liver's inferior ridge, the falciform ligament, and the occluding contours. These are usually marked by hand in both the laparoscopic image and the 3D model, which is time-consuming and prone to error. Therefore, there is a need to automate this process so that augmented reality can be used effectively in the operating room. We present the Preoperative-to-Intraoperative Laparoscopic Fusion challenge (P2ILF), held during the Medical Image Computing and Computer Assisted Intervention (MICCAI 2022) conference, which investigates the possibilities of detecting these landmarks automatically and using them in registration. The challenge was divided into two tasks: (1) A 2D and 3D landmark segmentation task and (2) a 3D-2D registration task. The teams were provided with training data consisting of 167 laparoscopic images and 9 preoperative 3D models from 9 patients, with the corresponding 2D and 3D landmark annotations. A total of 6 teams from 4 countries participated in the challenge, whose results were assessed for each task independently. All the teams proposed deep learning-based methods for the 2D and 3D landmark segmentation tasks and differentiable rendering-based methods for the registration task. The proposed methods were evaluated on 16 test images and 2 preoperative 3D models from 2 patients. In Task 1, the teams were able to segment most of the 2D landmarks, while the 3D landmarks showed to be more challenging to segment. In Task 2, only one team obtained acceptable qualitative and quantitative registration results. Based on the experimental outcomes, we propose three key hypotheses that determine current limitations and future directions for research in this domain.
Sharib Ali, Yamid Espinel, Yueming Jin, Peng Liu 0074, Bianca Güttner, Xukun Zhang, Lihua Zhang 0002, Thomas Dowrick, Matthew J. Clarkson, Shiting Xiao, Yifan Wu 0021, Lei Zhu 0003, Dai Sun, Micha Pfeiffer, Shahid Farid, Lena Maier-Hein, Emmanuel Buc, Adrien Bartoli
Medical Image Anal.18
2025 Navigating prevalence shifts in image analysis algorithm deployment
abstract
Domain gaps are significant obstacles to the clinical implementation of machine learning (ML) solutions for medical image analysis. Although current research emphasizes new training methods and network architectures, the specific impact of prevalence shifts on algorithms in real-world applications is often overlooked. Differences in class frequencies between development and deployment data are crucial, particularly for the widespread adoption of artificial intelligence (AI), as disease prevalence can vary greatly across different times and locations. Our contribution is threefold. Based on a diverse set of 30 medical classification tasks (1) we demonstrate that lack of prevalence shift handling can have severe consequences on the quality of calibration, decision threshold, and performance assessment. Furthermore, (2) we show that prevalences can be accurately and reliably estimated in a data-driven manner. Finally, (3) we propose a new workflow for prevalence-aware image classification that uses estimated deployment prevalences to adjust a trained classifier to a new environment, without requiring additional annotated deployment data. Comprehensive experiments indicate that our proposed approach could contribute to generating better classifier decisions and more reliable performance estimates compared to current practice.
Patrick Godau, Piotr Kalinowski, Evangelia Christodoulou, Annika Reinke, Minu Tizabi, Luciana Ferrer, Paul F. Jaeger, Lena Maier-Hein
Medical Image Anal.8
2024 FISBe: A Real-World Benchmark Dataset for Instance Segmentation of Long-Range thin Filamentous Structures
abstract
Instance segmentation of neurons in volumetric light microscopy images of nervous systems enables ground-breaking research in neuroscience by facilitating joint functional and morphological analyses of neural circuits at cel-lular resolution. Yet said multi-neuron light microscopy data exhibits extremely challenging properties for the task of instance segmentation: Individual neurons have long-ranging, thin filamentous and widely branching morpholo-gies, multiple neurons are tightly inter-weaved, and par-tial volume effects, uneven illumination and noise inherent to light microscopy severely impede local disentan-gling as well as long-range tracing of individual neurons. These properties reflect a current key challenge in machine learning research, namely to effectively capture long-range dependencies in the data. While respective method-ological research is buzzing, to date methods are typically benchmarked on synthetic datasets. To address this gap, we release the FlyLight Instance Segmentation Benchmark (FISBe) dataset, the first publicly available multi-neuron light microscopy dataset with pixel-wise annotations. In addition, we define a set of instance segmentation metrics for benchmarking that we designed to be meaningful with regard to downstream analyses. Lastly, we provide three baselines to kick off a competition that we envision to both advance the field of machine learning regarding methodology for capturing long-range data dependencies, and facilitate scientific discovery in basic neuroscience. Project page: https://kainmueller-lab.github.io/jisbe.
Lisa Mais, Peter Hirsch 0001, Claire Managan, Ramya Kandarpa, Josef Lorenz Rumberger, Annika Reinke, Lena Maier-Hein, Gudrun Ihrke, Dagmar Kainmüller
CVPR7
2024 Quality Assured: Rethinking Annotation Strategies in Imaging AI
abstract
Abstract This paper does not describe a novel method. Instead, it studies an essential foundation for reliable benchmarking and ultimately real-world application of AI-based image analysis: generating high-quality reference annotations. Previous research has focused on crowdsourcing as a means of outsourcing annotations. However, little attention has so far been given to annotation companies, specifically regarding their internal quality assurance (QA) processes. Therefore, our aim is to evaluate the influence of QA employed by annotation companies on annotation quality and devise methodologies for maximizing data annotation efficacy. Based on a total of 57,648 instance segmented images obtained from a total of 924 annotators and 34 QA workers from four annotation companies and Amazon Mechanical Turk (MTurk), we derived the following insights: (1) Annotation companies perform better both in terms of quantity and quality compared to the widely used platform MTurk. (2) Annotation companies’ internal QA only provides marginal improvements, if any. However, improving labeling instructions instead of investing in QA can substantially boost annotation performance. (3) The benefit of internal QA depends on specific image characteristics. Our work could enable researchers to derive substantially more value from a fixed annotation budget and change the way annotation companies conduct internal QA.
Tim Rädsch, Annika Reinke, Vivienn Weru, Minu Tizabi, Nicholas Heller, Fabian Isensee, Annette Kopp-Schneider, Lena Maier-Hein
ECCV (78)8
2024 Deep Intra-operative Illumination Calibration of Hyperspectral Cameras
abstract
Abstract Hyperspectral imaging (HSI) is emerging as a promising novel imaging modality with various potential surgical applications. Currently available cameras, however, suffer from poor integration into the clinical workflow because they require the lights to be switched off, or the camera to be manually recalibrated as soon as lighting conditions change. Given this critical bottleneck, the contribution of this paper is threefold: (1) We demonstrate that dynamically changing lighting conditions in the operating room dramatically affect the performance of HSI applications, namely physiological parameter estimation, and surgical scene segmentation. (2) We propose a novel learning-based approach to automatically recalibrating hyperspectral images during surgery and show that it is sufficiently accurate to replace the tedious process of white reference-based recalibration. (3) Based on a total of 742 HSI cubes from a phantom, porcine models, and rats we show that our recalibration method not only outperforms previously proposed methods, but also generalizes across species, lighting conditions, and image processing tasks. Due to its simple workflow integration as well as high accuracy, speed, and generalization capabilities, our method could evolve as a central component in clinical surgical HSI.
Alex Baumann, Leonardo Ayala, Alexander Studier-Fischer, Jan Sellner, Berkin Özdemir, Karl-Friedrich Kowalewski, Slobodan Ilic, Silvia Seidlitz, Lena Maier-Hein
MICCAI (6)9
2024 Confidence Intervals Uncovered: Are We Ready for Real-World Medical Imaging AI?
Evangelia Christodoulou, Annika Reinke, Rola Houhou, Piotr Kalinowski, Selen Erkan, Carole H. Sudre, Ninon Burgos, Sofiène Boutaj, Sophie Loizillon, Maëlys Solal, Nicola Rieke, Veronika Cheplygina, Michela Antonelli, Leon D. Mayer, Minu Tizabi, Manuel Jorge Cardoso, Amber L. Simpson, Paul F. Jaeger, Annette Kopp-Schneider, Gaël Varoquaux, Olivier Colliot, Lena Maier-Hein
MICCAI (10)22
2024 Overcoming Common Flaws in the Evaluation of Selective Classification Systems
abstract
Selective Classification, wherein models can reject low-confidence predictions, promises reliable translation of machine-learning based classification systems to real-world scenarios such as clinical diagnostics. While current evaluation of these systems typically assumes fixed working points based on pre-defined rejection thresholds, methodological progress requires benchmarking the general performance of systems akin to the $\mathrm{AUROC}$ in standard classification. In this work, we define 5 requirements for multi-threshold metrics in selective classification regarding task alignment, interpretability, and flexibility, and show how current approaches fail to meet them. We propose the Area under the Generalized Risk Coverage curve ($\mathrm{AUGRC}$), which meets all requirements and can be directly interpreted as the average risk of undetected failures. We empirically demonstrate the relevance of $\mathrm{AUGRC}$ on a comprehensive benchmark spanning 6 data sets and 13 confidence scoring functions. We find that the proposed metric substantially changes metric rankings on 5 out of the 6 data sets.
Jeremias Traub, Till J. Bungert, Carsten T. Lüth, Michael Baumgartner 0001, Klaus H. Maier-Hein, Lena Maier-Hein, Paul F. Jaeger
NeurIPS6
2024 Photoacoustic Quantification of Tissue Oxygenation Using Conditional Invertible Neural Networks
abstract
Intelligent systems in interventional healthcare depend on the reliable perception of the environment. In this context, photoacoustic tomography (PAT) has emerged as a non-invasive, functional imaging modality with great clinical potential. Current research focuses on converting the high-dimensional, not human-interpretable spectral data into the underlying functional information, specifically the blood oxygenation. One of the largely unexplored issues stalling clinical advances is the fact that the quantification problem is ambiguous, i.e. that radically different tissue parameter configurations could lead to almost identical photoacoustic spectra. In the present work, we tackle this problem with conditional Invertible Neural Networks (cINNs). Going beyond traditional point estimates, our network is used to compute an approximation of the conditional posterior density of tissue parameters given the photoacoustic spectrum. To this end, an automatic mode detection algorithm extracts the plausible solution from the sample-based posterior. According to a comprehensive validation study based on both synthetic and real images, our approach is well-suited for exploring ambiguity in quantitative PAT.
Jan-Hinrich Nölke, Tim Adler, Melanie Schellenberg, Kris Dreher, Niklas Holzwarth, Christoph J. Bender, Minu Tizabi, Alexander Seitel, Lena Maier-Hein
IEEE Trans. Medical Imaging9
2023 Why is the Winner the Best?
abstract
International benchmarking competitions have become fundamental for the comparative performance assessment of image analysis methods. However, little attention has been given to investigating what can be learnt from these competitions. Do they really generate scientific progress? What are common and successful participation strategies? What makes a solution superior to a competing method? To address this gap in the literature, we performed a multicenter study with all 80 competitions that were conducted in the scope of IEEE ISBI 2021 and MICCAI 2021. Statistical analyses performed based on comprehensive descriptions of the submitted algorithms linked to their rank as well as the underlying participation strategies revealed common characteristics of winning solutions. These typically include the use of multi-task learning (63%) and/or multi-stage pipelines (61%), and a focus on augmentation (100%), image preprocessing (97%), data curation (79%), and post-processing (66%). The “typical” lead of a winning team is a computer scientist with a doctoral degree, five years of experience in biomedical image analysis, and four years of experience in deep learning. Two core general development strategies stood out for highly-ranked teams: the reflection of the metrics in the method design and the focus on analyzing and handling failure cases. According to the organizers, 43% of the winning algorithms exceeded the state of the art but only 11% completely solved the respective domain problem. The insights of our study could help researchers (1) improve algorithm development strategies when approaching new problems, and (2) focus on open research questions revealed by this work.
Matthias Eisenmann, Annika Reinke, Vivienn Weru, Minu Tizabi, Fabian Isensee, Tim Adler, Sharib Ali, Vincent Andrearczyk, Marc Aubreville, Ujjwal Baid, Spyridon Bakas, Niranjan Balu, Sophia Bano, Jorge Bernal, Sebastian Bodenstedt, Alessandro Casella, Veronika Cheplygina, Marie Daum, Marleen de Bruijne, Adrien Depeursinge, Reuben Dorent, Jan Egger, David Gage Ellis, Sandy Engelhardt, Melanie Ganz-Benjaminsen, Noha M. Ghatwary, Gabriel Girard, Patrick Godau, Anubha Gupta, Lasse Hansen, Kanako Harada, Mattias P. Heinrich, Nicholas Heller, Alessa Hering, Arnaud Huaulmé, Pierre Jannin, A. Emre Kavur, Oldrich Kodym, Michal Kozubek 0001, Jianning Li 0002, Hongwei Li 0004, Jun Ma 0016, Carlos Martín-Isla, Bjoern Menze, J. Alison Noble, Valentin Oreiller, Nicolas Padoy, Sarthak Pati, Kelly Payette, Tim Rädsch, Jonathan Rafael-Patino, Vivek Singh Bawa, Stefanie Speidel, Carole H. Sudre, Kimberlin M. H. van Wijnen, Martin Wagner 0001, D. Wei, Amine Yamlahi, Moi Hoon Yap, C. Yuan, Maximilian Zenk, A. Zia, David Zimmerer, Dogu Baran Aydogan, Binod Bhattarai, Louise Bloch, Raphael Brüngel, J. Cho, C. Choi, Qi Dou 0001, Ivan Ezhov, Christoph M. Friedrich, C. Fuller, Rebati Raman Gaire, Adrian Galdran, Álvaro García-Faura, Maria Grammatikopoulou, S. Hong, Mostafa Jahanifar, I. Jang, Abdolrahim Kadkhodamohammadi, I. Kang, Florian Kofler, S. Kondo, Hugo J. Kuijf, M. Luu, Tomaz Martincic, Pedro Morais, Mohamed A. Naser, Bruno Oliveira 0002, David Owen 0001, S. Pang, Szymon Plotka, Élodie Puybareau, Nasir M. Rajpoot, K. Ryu, Numan Saeed, Adam J. Shephard, Dejan Stepec, Ronast Subedi, Guillaume Tochon, Helena R. Torres, Hélène Urien, João L. Vilaça, Kareem A. Wahid, Benedikt Wiestler, Marek Wodzinski, F. Xia, J. Xie, Z. Xiong, Sen Yang 0006, Klaus H. Maier-Hein, Paul F. Jaeger, Annette Kopp-Schneider, Lena Maier-Hein
CVPR125
2023 Unsupervised Domain Transfer with Conditional Invertible Neural Networks
abstract
Abstract Synthetic medical image generation has evolved as a key technique for neural network training and validation. A core challenge, however, remains in the domain gap between simulations and real data. While deep learning-based domain transfer using Cycle Generative Adversarial Networks and similar architectures has led to substantial progress in the field, there are use cases in which state-of-the-art approaches still fail to generate training images that produce convincing results on relevant downstream tasks. Here, we address this issue with a domain transfer approach based on conditional invertible neural networks (cINNs). As a particular advantage, our method inherently guarantees cycle consistency through its invertible architecture, and network training can efficiently be conducted with maximum likelihood training. To showcase our method’s generic applicability, we apply it to two spectral imaging modalities at different scales, namely hyperspectral imaging (pixel-level) and photoacoustic tomography (image-level). According to comprehensive experiments, our method enables the generation of realistic spectral data and outperforms the state of the art on two downstream classification tasks (binary and multi-class). cINN-based domain transfer could thus evolve as an important method for realistic synthetic data generation in the field of spectral imaging and beyond. The code is available at https://github.com/IMSY-DKFZ/UDT-cINN .
Kris Dreher, Leonardo Ayala, Melanie Schellenberg, Marco Hübner, Jan-Hinrich Nölke, Tim Adler, Silvia Seidlitz, Jan Sellner, Alexander Studier-Fischer, Janek Gröhl, Felix Nickel, Ullrich Köthe, Alexander Seitel, Lena Maier-Hein
MICCAI (1)14
2023 Deployment of Image Analysis Algorithms Under Prevalence Shifts
Patrick Godau, Piotr Kalinowski, Evangelia Christodoulou, Annika Reinke, Minu Tizabi, Luciana Ferrer, Paul F. Jaeger, Lena Maier-Hein
MICCAI (3)8
2023 Semantic Segmentation of Surgical Hyperspectral Images Under Geometric Domain Shifts
Jan Sellner, Silvia Seidlitz, Alexander Studier-Fischer, Alessandro Motta, Berkin Özdemir, Beat P. Müller-Stich, Felix Nickel, Lena Maier-Hein
MICCAI (9)8
2023 Self-distillation for Surgical Action Recognition
Amine Yamlahi, Thuy Nuong Tran, Patrick Godau, Melanie Schellenberg, Dominik Michael, Finn-Henri Smidt, Jan-Hinrich Nölke, Tim Adler, Minu Tizabi, Chinedu Innocent Nwoye, Nicolas Padoy, Lena Maier-Hein
MICCAI (9)12
2023 CholecTriplet2022: Show me a tool and tell me the triplet - An endoscopic vision challenge for surgical action triplet detection
Chinedu Innocent Nwoye, Tong Yu 0009, Saurav Sharma, Aditya Murali, Deepak Alapatt, Armine Vardazaryan, Kun Yuan 0004, Jonas Hajek, Wolfgang Reiter, Amine Yamlahi, Finn-Henri Smidt, Xiaoyang Zou, Guoyan Zheng, Bruno Oliveira 0002, Helena R. Torres, Satoshi Kondo, Satoshi Kasai, Felix Holm, Ege Özsoy, Shuangchun Gui, Sista Raviteja, Rachana Sathish, Pranav Poudel, Binod Bhattarai, Ziheng Wang 0003, Guo Rui, Melanie Schellenberg, João L. Vilaça, Tobias Czempiel, Zhenkun Wang 0001, Debdoot Sheet, Shrawan Kumar Thapa, Max Berniker, Patrick Godau, Pedro Morais, Sudarshan Regmi, Thuy Nuong Tran, Jaime C. Fonseca 0001, Jan-Hinrich Nölke, Estevão Lima, Eduard Vazquez, Lena Maier-Hein, Nassir Navab, Pietro Mascagni, Barbara Seeliger, Cristians Gonzalez, Didier Mutter, Nicolas Padoy
Medical Image Anal.43
2023 Beyond rankings: Learning (more) from algorithm validation
abstract
Challenges have become the state-of-the-art approach to benchmark image analysis algorithms in a comparative manner. While the validation on identical data sets was a great step forward, results analysis is often restricted to pure ranking tables, leaving relevant questions unanswered. Specifically, little effort has been put into the systematic investigation on what characterizes images in which state-of-the-art algorithms fail. To address this gap in the literature, we (1) present a statistical framework for learning from challenges and (2) instantiate it for the specific task of instrument instance segmentation in laparoscopic videos. Our framework relies on the semantic meta data annotation of images, which serves as foundation for a General Linear Mixed Models (GLMM) analysis. Based on 51,542 meta data annotations performed on 2,728 images, we applied our approach to the results of the Robust Medical Instrument Segmentation Challenge (ROBUST-MIS) challenge 2019 and revealed underexposure, motion and occlusion of instruments as well as the presence of smoke or other objects in the background as major sources of algorithm failure. Our subsequent method development, tailored to the specific remaining issues, yielded a deep learning model with state-of-the-art overall performance and specific strengths in the processing of images in which previous methods tended to fail. Due to the objectivity and generic applicability of our approach, it could become a valuable tool for validation in the field of medical image analysis and beyond.
Tobias Roß, Pierangela Bruno, Annika Reinke, Manuel Wiesenfarth, Lisa Koeppel, Peter M. Full, Bünyamin Pekdemir, Patrick Godau, Darya Trofimova, Fabian Isensee, Tim Adler, Thuy Nuong Tran, Sara Moccia, Francesco Calimeri, Beat P. Müller-Stich, Annette Kopp-Schneider, Lena Maier-Hein
Medical Image Anal.17
2023 Comparative validation of machine learning algorithms for surgical workflow and skill analysis with the HeiChole benchmark
abstract
PURPOSE: Surgical workflow and skill analysis are key technologies for the next generation of cognitive surgical assistance systems. These systems could increase the safety of the operation through context-sensitive warnings and semi-autonomous robotic assistance or improve training of surgeons via data-driven feedback. In surgical workflow analysis up to 91% average precision has been reported for phase recognition on an open data single-center video dataset. In this work we investigated the generalizability of phase recognition algorithms in a multicenter setting including more difficult recognition tasks such as surgical action and surgical skill. METHODS: To achieve this goal, a dataset with 33 laparoscopic cholecystectomy videos from three surgical centers with a total operation time of 22 h was created. Labels included framewise annotation of seven surgical phases with 250 phase transitions, 5514 occurences of four surgical actions, 6980 occurences of 21 surgical instruments from seven instrument categories and 495 skill classifications in five skill dimensions. The dataset was used in the 2019 international Endoscopic Vision challenge, sub-challenge for surgical workflow and skill analysis. Here, 12 research teams trained and submitted their machine learning algorithms for recognition of phase, action, instrument and/or skill assessment. RESULTS: F1-scores were achieved for phase recognition between 23.9% and 67.7% (n = 9 teams), for instrument presence detection between 38.5% and 63.8% (n = 8 teams), but for action recognition only between 21.8% and 23.3% (n = 5 teams). The average absolute error for skill assessment was 0.78 (n = 1 team). CONCLUSION: Surgical workflow and skill analysis are promising technologies to support the surgical team, but there is still room for improvement, as shown by our comparison of machine learning algorithms. This novel HeiChole benchmark can be used for comparable evaluation and validation of future work. In future studies, it is of utmost importance to create more open, high-quality datasets in order to allow the development of artificial intelligence and cognitive robotics in surgery.
Martin Wagner 0001, Beat P. Müller-Stich, Anna Kisilenko, Patrick Heger, Lars Mündermann, David M. Lubotsky, Tornike Davitashvili, Manuela Capek, Annika Reinke, Carissa Reid, Tong Yu 0009, Armine Vardazaryan, Chinedu Innocent Nwoye, Nicolas Padoy, Eungjoo Lee 0001, Constantin Disch, Hans Meine, Tong Xia, Fucang Jia, Satoshi Kondo, Wolfgang Reiter, Yueming Jin, Yonghao Long 0001, Meirui Jiang, Qi Dou 0001, Pheng-Ann Heng, Isabell Twick, Kadir Kirtaç, Enes Hosgor, Jon Lindström Bolmgren, Michael Stenzel, Björn von Siemens, Zhenxiao Ge, Haiming Sun, Di Xie, Mengqi Guo, Daochang Liu, Hannes Kenngott, Felix Nickel, Moritz von Frankenberg, Franziska Mathis-Ullrich, Annette Kopp-Schneider, Lena Maier-Hein, Stefanie Speidel, Sebastian Bodenstedt
Medical Image Anal.47
2022 SERV-CT: A disparity dataset from cone-beam CT for validation of endoscopic 3D reconstruction
abstract
In computer vision, reference datasets from simulation and real outdoor scenes have been highly successful in promoting algorithmic development in stereo reconstruction. Endoscopic stereo reconstruction for surgical scenes gives rise to specific problems, including the lack of clear corner features, highly specular surface properties and the presence of blood and smoke. These issues present difficulties for both stereo reconstruction itself and also for standardised dataset production. Previous datasets have been produced using computed tomography (CT) or structured light reconstruction on phantom or ex vivo models. We present a stereo-endoscopic reconstruction validation dataset based on cone-beam CT (SERV-CT). Two ex vivo small porcine full torso cadavers were placed within the view of the endoscope with both the endoscope and target anatomy visible in the CT scan. Subsequent orientation of the endoscope was manually aligned to match the stereoscopic view and benchmark disparities, depths and occlusions are calculated. The requirement of a CT scan limited the number of stereo pairs to 8 from each ex vivo sample. For the second sample an RGB surface was acquired to aid alignment of smooth, featureless surfaces. Repeated manual alignments showed an RMS disparity accuracy of around 2 pixels and a depth accuracy of about 2 mm. A simplified reference dataset is provided consisting of endoscope image pairs with corresponding calibration, disparities, depths and occlusions covering the majority of the endoscopic image and a range of tissue types, including smooth specular surfaces, as well as significant variation of depth. We assessed the performance of various stereo algorithms from online available repositories. There is a significant variation between algorithms, highlighting some of the challenges of surgical endoscopic images. The SERV-CT dataset provides an easy to use stereoscopic validation for surgical applications with smooth reference disparities and depths covering the majority of the endoscopic image. This complements existing resources well and we hope will aid the development of surgical endoscopic anatomical reconstruction algorithms.
Philip J. Edwards, Dimitris Psychogyios, Stefanie Speidel, Lena Maier-Hein, Danail Stoyanov
Medical Image Anal.4
2022 C-arm positioning for standard projections during spinal implant placement
abstract
Fluoroscopy-guided trauma and orthopedic surgeries involve the repeated acquisition of correct anatomy-specific standard projections for guidance, monitoring, and evaluating the surgical result. C-arm positioning is usually performed by hand, involving repeated or even continuous fluoroscopy at a cost of radiation exposure and time. We propose to automate this procedure and estimate the pose update for C-arm repositioning directly from a first X-ray without the need for a patient-specific computed tomography scan (CT) or additional technical equipment. Our method is trained on digitally reconstructed radiographs (DRRs) which uniquely provide ground truth labels for an arbitrary number of training examples. The simulated images are complemented with automatically generated segmentations, landmarks, and with simulated k-wires and screws. To successfully achieve a transfer from simulated to real X-rays, and also to increase the interpretability of results, the pipeline was designed to closely reflect the actual clinical decision-making process followed by spinal neurosurgeons. It explicitly incorporates steps such as region-of-interest (ROI) localization, detection of relevant and view-independent landmarks, and subsequent pose regression. The method was validated on a large human cadaver study simulating a real clinical scenario, including k-wires and screws. The proposed procedure obtained superior C-arm positioning accuracy of dθ=8.8°±4.2° average improvement (pt−test≪0.01), robustness, and generalization capabilities compared to the state-of-the-art direct pose regression framework.
Lisa Kausch, Sarina Thomas, Holger Kunze, Tobias Norajitra, André Klein, Leonardo Ayala, Jan Siad El Barbari, Eric Mandelka, Maxim Privalov, Sven Yves Vetter, Andreas H. Mahnken, Lena Maier-Hein, Klaus H. Maier-Hein
Medical Image Anal.12
2022 Surgical data science - from concepts toward clinical translation
abstract
Recent developments in data science in general and machine learning in particular have transformed the way experts envision the future of surgery. Surgical Data Science (SDS) is a new research field that aims to improve the quality of interventional healthcare through the capture, organization, analysis and modeling of data. While an increasing number of data-driven approaches and clinical applications have been studied in the fields of radiological and clinical data science, translational success stories are still lacking in surgery. In this publication, we shed light on the underlying reasons and provide a roadmap for future advances in the field. Based on an international workshop involving leading researchers in the field of SDS, we review current practice, key achievements and initiatives as well as available standards and tools for a number of topics relevant to the field, namely (1) infrastructure for data acquisition, storage and access in the presence of regulatory constraints, (2) data annotation and sharing and (3) data analytics. We further complement this technical perspective with (4) a review of currently available SDS products and the translational progress from academia and (5) a roadmap for faster clinical translation and exploitation of the full potential of SDS, based on an international multi-round Delphi process.
Lena Maier-Hein, Matthias Eisenmann, Duygu Sarikaya, Keno März, Toby Collins, Anand Malpani, Johannes Fallert, Hubertus Feußner, Stamatia Giannarou, Pietro Mascagni, Hirenkumar Nakawala, Adrian Park 0001, Carla M. Pugh, Danail Stoyanov, S. Swaroop Vedula, Kevin Cleary, Gabor Fichtinger, Germain Forestier, Bernard Gibaud, Teodor P. Grantcharov, Makoto Hashizume, Doreen Heckmann-Nötzel, Hannes Kenngott, Ron Kikinis, Lars Mündermann, Nassir Navab, Sinan Onogur, Tobias Roß, Raphael Sznitman, Russell H. Taylor, Minu Tizabi, Martin Wagner 0001, Gregory D. Hager, Thomas Neumuth, Nicolas Padoy, Justin Collins, Ines Gockel, Jan Goedeke, Daniel A. Hashimoto, Luc Joyeux, Kyle Lam, Daniel Richard Leff, Amin Madani, Hani J. Marcus, Ozanan R. Meireles, Alexander Seitel, Dogu Teber, Frank Ückert, Beat P. Müller-Stich, Pierre Jannin, Stefanie Speidel
Medical Image Anal.1
2022 Robust deep learning-based semantic organ segmentation in hyperspectral images
abstract
Semantic image segmentation is an important prerequisite for context-awareness and autonomous robotics in surgery. The state of the art has focused on conventional RGB video data acquired during minimally invasive surgery, but full-scene semantic segmentation based on spectral imaging data and obtained during open surgery has received almost no attention to date. To address this gap in the literature, we are investigating the following research questions based on hyperspectral imaging (HSI) data of pigs acquired in an open surgery setting: (1) What is an adequate representation of HSI data for neural network-based fully automated organ segmentation, especially with respect to the spatial granularity of the data (pixels vs. superpixels vs. patches vs. full images)? (2) Is there a benefit of using HSI data compared to other modalities, namely RGB data and processed HSI data (e.g. tissue parameters like oxygenation), when performing semantic organ segmentation? According to a comprehensive validation study based on 506 HSI images from 20 pigs, annotated with a total of 19 classes, deep learning-based segmentation performance increases - consistently across modalities - with the spatial context of the input data. Unprocessed HSI data offers an advantage over RGB data or processed data from the camera provider, with the advantage increasing with decreasing size of the input to the neural network. Maximum performance (HSI applied to whole images) yielded a mean DSC of 0.90 ((standard deviation (SD)) 0.04), which is in the range of the inter-rater variability (DSC of 0.89 ((standard deviation (SD)) 0.07)). We conclude that HSI could become a powerful image modality for fully-automatic surgical scene understanding with many advantages over traditional imaging, including the ability to recover additional functional tissue information. Our code and pre-trained models are available at https://github.com/IMSY-DKFZ/htc.
Silvia Seidlitz, Jan Sellner, Jan Odenthal, Berkin Özdemir, Alexander Studier-Fischer, Samuel Knödler, Leonardo Ayala, Tim Adler, Hannes Kenngott, Minu Tizabi, Martin Wagner 0001, Felix Nickel, Beat P. Müller-Stich, Lena Maier-Hein
Medical Image Anal.14
2022 MOOD 2020: A Public Benchmark for Out-of-Distribution Detection and Localization on Medical Images
abstract
Detecting Out-of-Distribution (OoD) data is one of the greatest challenges in safe and robust deployment of machine learning algorithms in medicine. When the algorithms encounter cases that deviate from the distribution of the training data, they often produce incorrect and over-confident predictions. OoD detection algorithms aim to catch erroneous predictions in advance by analysing the data distribution and detecting potential instances of failure. Moreover, flagging OoD cases may support human readers in identifying incidental findings. Due to the increased interest in OoD algorithms, benchmarks for different domains have recently been established. In the medical imaging domain, for which reliable predictions are often essential, an open benchmark has been missing. We introduce the Medical-Out-Of-Distribution-Analysis-Challenge (MOOD) as an open, fair, and unbiased benchmark for OoD methods in the medical imaging domain. The analysis of the submitted algorithms shows that performance has a strong positive correlation with the perceived difficulty, and that all algorithms show a high variance for different anomalies, making it yet hard to recommend them for clinical practice. We also see a strong correlation between challenge ranking and performance on a simple toy test set, indicating that this might be a valuable addition as a proxy dataset during anomaly detection algorithm development.
David Zimmerer, Peter M. Full, Fabian Isensee, Paul F. Jaeger, Tim Adler, Jens Petersen, Gregor Köhler, Tobias Roß, Annika Reinke, Antanas Kascenas, Bjørn Sand Jensen, Alison O'Neil, Jeremy Tan, Benjamin Hou, James Batten, Huaqi Qiu, Bernhard Kainz, Nina Shvetsova, Irina Fedulova, Dmitry V. Dylov, Baolun Yu, Jianyang Zhai, Jingtao Hu, Runxuan Si, Sihang Zhou 0001, Siqi Wang 0001, Xuerun Chen, Yang Zhao 0003, Sergio Naval Marimont, Giacomo Tarroni, Victor Saase, Lena Maier-Hein, Klaus H. Maier-Hein
IEEE Trans. Medical Imaging33
2021 Task Fingerprinting for Meta Learning inBiomedical Image Analysis
Patrick Godau, Lena Maier-Hein
MICCAI (4)2
2021 C-Arm Positioning for Spinal Standard Projections in Different Intra-operative Settings
Lisa Kausch, Sarina Thomas, Holger Kunze, Tobias Norajitra, André Klein, Jan Siad El Barbari, Maxim Privalov, Sven Yves Vetter, Andreas H. Mahnken, Lena Maier-Hein, Klaus H. Maier-Hein
MICCAI (4)10
2021 Corrigendum to Dual-modality endoscopic probe for tissue surface shape reconstruction and hyperspectral imaging enabled by deep neural networks [Medical Image Analysis 48 (2018) 162-176/2018.06.004]
Jianyu Lin, Neil Clancy, Taran Tatla, Danail Stoyanov, Lena Maier-Hein, Daniel S. Elson
Medical Image Anal.7
2021 Comparative validation of multi-instance instrument segmentation in endoscopy: Results of the ROBUST-MIS 2019 challenge
abstract
Intraoperative tracking of laparoscopic instruments is often a prerequisite for computer and robotic-assisted interventions. While numerous methods for detecting, segmenting and tracking of medical instruments based on endoscopic video images have been proposed in the literature, key limitations remain to be addressed: Firstly, robustness, that is, the reliable performance of state-of-the-art methods when run on challenging images (e.g. in the presence of blood, smoke or motion artifacts). Secondly, generalization; algorithms trained for a specific intervention in a specific hospital should generalize to other interventions or institutions. In an effort to promote solutions for these limitations, we organized the Robust Medical Instrument Segmentation (ROBUST-MIS) challenge as an international benchmarking competition with a specific focus on the robustness and generalization capabilities of algorithms. For the first time in the field of endoscopic image processing, our challenge included a task on binary segmentation and also addressed multi-instance detection and segmentation. The challenge was based on a surgical data set comprising 10,040 annotated images acquired from a total of 30 surgical procedures from three different types of surgery. The validation of the competing methods for the three tasks (binary segmentation, multi-instance detection and multi-instance segmentation) was performed in three different stages with an increasing domain gap between the training and the test data. The results confirm the initial hypothesis, namely that algorithm performance degrades with an increasing domain gap. While the average detection and segmentation quality of the best-performing algorithms is high, future research should concentrate on detection and segmentation of small, crossing, moving and transparent instrument(s) (parts).
Tobias Roß, Annika Reinke, Peter M. Full, Martin Wagner 0001, Hannes Kenngott, Martin Apitz, Hellena Hempe, Diana Mîndroc-Filimon, Patrick Godau, Thuy Nuong Tran, Pierangela Bruno, Pablo Andrés Arbeláez, Guibin Bian, Sebastian Bodenstedt, Jon Lindström Bolmgren, Laura Bravo-Sánchez, Hua-Bin Chen, Cristina González, Pål Halvorsen, Pheng-Ann Heng, Enes Hosgor, Zeng-Guang Hou, Fabian Isensee, Debesh Jha, Tingting Jiang 0001, Yueming Jin, Kadir Kirtaç, Sabrina Kletz, Stefan Leger, Klaus H. Maier-Hein, Zhen-Liang Ni, Michael Riegler 0001, Klaus Schöffmann, Ruohua Shi, Stefanie Speidel, Michael Stenzel, Isabell Twick, Guotai Wang, Jiacheng Wang 0002, Liansheng Wang 0002, Lu Wang 0002, Yan-Jie Zhou, Lei Zhu 0003, Manuel Wiesenfarth, Annette Kopp-Schneider, Beat P. Müller-Stich, Lena Maier-Hein
Medical Image Anal.50
2020 Surgical spectral imaging
abstract
Recent technological developments have resulted in the availability of miniaturised spectral imaging sensors capable of operating in the multi- (MSI) and hyperspectral imaging (HSI) regimes. Simultaneous advances in image-processing techniques and artificial intelligence (AI), especially in machine learning and deep learning, have made these data-rich modalities highly attractive as a means of extracting biological information non-destructively. Surgery in particular is poised to benefit from this, as spectrally-resolved tissue optical properties can offer enhanced contrast as well as diagnostic and guidance information during interventions. This is particularly relevant for procedures where inherent contrast is low under standard white light visualisation. This review summarises recent work in surgical spectral imaging (SSI) techniques, taken from Pubmed, Google Scholar and arXiv searches spanning the period 2013-2019. New hardware, optimised for use in both open and minimally-invasive surgery (MIS), is described, and recent commercial activity is summarised. Computational approaches to extract spectral information from conventional colour images are reviewed, as tip-mounted cameras become more commonplace in MIS. Model-based and machine learning methods of data analysis are discussed in addition to simulation, phantom and clinical validation experiments. A wide variety of surgical pilot studies are reported but it is apparent that further work is needed to quantify the clinical value of MSI/HSI. The current trend toward data-driven analysis emphasises the importance of widely-available, standardised spectral imaging datasets, which will aid understanding of variability across organs and patients, and drive clinical translation.
Neil Clancy, Geoffrey Jones, Lena Maier-Hein, Daniel S. Elson, Danail Stoyanov
Medical Image Anal.3
2020 BIAS: Transparent reporting of biomedical image analysis challenges
abstract
The number of biomedical image analysis challenges organized per year is steadily increasing. These international competitions have the purpose of benchmarking algorithms on common data sets, typically to identify the best method for a given problem. Recent research, however, revealed that common practice related to challenge reporting does not allow for adequate interpretation and reproducibility of results. To address the discrepancy between the impact of challenges and the quality (control), the Biomedical Image Analysis ChallengeS (BIAS) initiative developed a set of recommendations for the reporting of challenges. The BIAS statement aims to improve the transparency of the reporting of a biomedical image analysis challenge regardless of field of application, image modality or task category assessed. This article describes how the BIAS statement was developed and presents a checklist which authors of biomedical image analysis challenges are encouraged to include in their submission when giving a paper on a challenge into review. The purpose of the checklist is to standardize and facilitate the review process and raise interpretability and reproducibility of challenge results by making relevant information explicit.
Lena Maier-Hein, Annika Reinke, Michal Kozubek 0001, Anne L. Martel, Tal Arbel, Matthias Eisenmann, Allan Hanbury, Pierre Jannin, Henning Müller, Sinan Onogur, Julio Saez-Rodriguez, Bram van Ginneken, Annette Kopp-Schneider, Bennett A. Landman
Medical Image Anal.1
2019 Generating Large Labeled Data Sets for Laparoscopic Image Processing Tasks Using Unpaired Image-to-Image Translation
Micha Pfeiffer, Isabel Funke, Maria Robu, Sebastian Bodenstedt, Leon Strenger, Sandy Engelhardt, Tobias Roß, Matthew J. Clarkson, Kurinchi Gurusamy, Brian R. Davidson, Lena Maier-Hein, Carina Riediger, Thilo Welsch, Jürgen Weitz, Stefanie Speidel
MICCAI (5)11
2019 Patch-based adaptive weighting with segmentation and scale (PAWSS) for visual tracking in surgical video
abstract
Vision-based tracking in an important component for building computer assisted interventions in minimally invasive surgery as it facilitates estimation of motion for instruments and anatomical targets. Tracking-by-detection algorithms are widely used for visual tracking, where the problem is treated as a classification task and a tracking target appearance model is updated over time using online learning. In challenging conditions, like surgical scenes, where tracking targets deform and vary in scale, the update step is prone to include background information in model appearance or to lack the ability to estimate change of scale, which degrades the performance of classifier. In this paper, we propose a Patch-based Adaptive Weighting with Segmentation and Scale (PAWSS) tracking framework that tackles both scale and background problems. A simple but effective colour-based segmentation model is used to suppress background information and multi-scale samples are extracted to enrich the training pool, which allows the tracker to handle both incremental and abrupt scale variations between frames. Experimentally, we evaluate our approach on Online Tracking Benchmark (OTB) dataset and Visual Object Tracking (VOT) challenge datasets, showing that our approach outperforms recent state-of-the-art trackers, and it especially improves successful rate score on OTB dataset, while on VOT datasets, PAWSS ranks among the top trackers while operating at real-time frame rates. Focusing on the application of PAWSS to surgical scenes, we evaluate on MICCAI 2015 challenge instrument tracking challenge and in vivo datasets, showing that our approach performs the best among all submitted methods and also has promising performance on in vivo surgical instrument tracking.
Xiaofei Du 0001, Maximilian Allan, Sebastian Bodenstedt, Lena Maier-Hein, Stefanie Speidel, Alessio Dore, Danail Stoyanov
Medical Image Anal.4
2018 How to Exploit Weaknesses in Biomedical Challenge Design and Organization
Annika Reinke, Matthias Eisenmann, Sinan Onogur, Marko Stankovic 0002, Patrick Godau, Peter M. Full, Hrvoje Bogunovic, Bennett A. Landman, Oskar Maier, Bjoern Menze, Gregory C. Sharp, Korsuk Sirinukunwattana, Stefanie Speidel, Fons van der Sommen, Guoyan Zheng, Henning Müller, Michal Kozubek 0001, Tal Arbel, Andrew P. Bradley, Pierre Jannin, Annette Kopp-Schneider, Lena Maier-Hein
MICCAI (4)22
2018 Special Issue on MICCAI 2017
Maxime Descoteaux, Lena Maier-Hein, Alfred M. Franz, Pierre Jannin, D. Louis Collins, Simon Duchesne
Medical Image Anal.2
2018 Dual-modality endoscopic probe for tissue surface shape reconstruction and hyperspectral imaging enabled by deep neural networks
Jianyu Lin, Neil Clancy, Taran Tatla, Danail Stoyanov, Lena Maier-Hein, Daniel S. Elson
Medical Image Anal.7
2018 Clickstream Analysis for Crowd-Based Object Segmentation with Confidence
abstract
With the rapidly increasing interest in machine learning based solutions for automatic image annotation, the availability of reference annotations for algorithm training is one of the major bottlenecks in the field. Crowdsourcing has evolved as a valuable option for low-cost and large-scale data annotation; however, quality control remains a major issue which needs to be addressed. To our knowledge, we are the first to analyze the annotation process to improve crowd-sourced image segmentation. Our method involves training a regressor to estimate the quality of a segmentation from the annotator's clickstream data. The quality estimation can be used to identify spam and weight individual annotations by their (estimated) quality when merging multiple segmentations of one image. Using a total of 29,000 crowd annotations performed on publicly available data of different object classes, we show that (1) our method is highly accurate in estimating the segmentation quality based on clickstream data, (2) outperforms state-of-the-art methods for merging multiple annotations. As the regressor does not need to be trained on the object class that it is applied to it can be regarded as a low-cost option for quality control and confidence analysis in the context of crowd-based image annotation.
Eric Heim, Alexander Seitel, Jonas Andrulis, Fabian Isensee, Christian Stock, Tobias Roß, Lena Maier-Hein
IEEE Trans. Pattern Anal. Mach. Intell.7
2017 Endoscopic Depth Measurement and Super-Spectral-Resolution Imaging
Jianyu Lin, Neil Clancy, Taran Tatla, Danail Stoyanov, Lena Maier-Hein, Daniel S. Elson
MICCAI (2)7
2017 Physiological Parameter Estimation from Multispectral Images Unleashed
Sebastian J. Wirkert, Anant Suraj Vemuri, Hannes Kenngott, Sara Moccia, Michael Götz, Benjamin F. B. Mayer, Klaus H. Maier-Hein, Daniel S. Elson, Lena Maier-Hein
MICCAI (3)9
2017 Comparative Validation of Polyp Detection Methods in Video Colonoscopy: Results From the MICCAI 2015 Endoscopic Vision Challenge
abstract
Colonoscopy is the gold standard for colon cancer screening though some polyps are still missed, thus preventing early disease detection and treatment. Several computational systems have been proposed to assist polyp detection during colonoscopy but so far without consistent evaluation. The lack of publicly available annotated databases has made it difficult to compare methods and to assess if they achieve performance levels acceptable for clinical use. The Automatic Polyp Detection sub-challenge, conducted as part of the Endoscopic Vision Challenge (http://endovis.grand-challenge.org) at the international conference on Medical Image Computing and Computer Assisted Intervention (MICCAI) in 2015, was an effort to address this need. In this paper, we report the results of this comparative evaluation of polyp detection methods, as well as describe additional experiments to further explore differences between methods. We define performance metrics and provide evaluation databases that allow comparison of multiple methodologies. Results show that convolutional neural networks are the state of the art. Nevertheless, it is also demonstrated that combining different methodologies can lead to an improved overall performance.
Jorge Bernal, Nima Tajkbaksh, Francisco Javier Sánchez, Bogdan J. Matuszewski, Hao Chen 0011, Lequan Yu, Quentin Angermann, Olivier Romain, Bjorn Rustad, Ilangko Balasingham, Konstantin Pogorelov, Sungbin Choi, Quentin Debard, Lena Maier-Hein, Stefanie Speidel, Danail Stoyanov, Patrick Brandao, Henry Córdova, Cristina Sánchez-Montes, Suryakanth R. Gurudu, Gloria Fernández-Esparrach, Xavier Dray, Jianming Liang, Aymeric Histace
IEEE Trans. Medical Imaging14
2016 Crowd-Algorithm Collaboration for Large-Scale Endoscopic Image Annotation with Confidence
Lena Maier-Hein, Tobias Roß, Janek Gröhl, Ben Glocker, Sebastian Bodenstedt, Christian Stock, Eric Heim, Michael Götz, Sebastian J. Wirkert, Hannes Kenngott, Stefanie Speidel, Klaus H. Maier-Hein
MICCAI (2)1
2015 The HCI Stereo Metrics: Geometry-Aware Performance Analysis of Stereo Algorithms
abstract
Performance characterization of stereo methods is mandatory to decide which algorithm is useful for which application. Prevalent benchmarks mainly use the root mean squared error (RMS) with respect to ground truth disparity maps to quantify algorithm performance. We show that the RMS is of limited expressiveness for algorithm selection and introduce the HCI Stereo Metrics. These metrics assess stereo results by harnessing three semantic cues: depth discontinuities, planar surfaces, and fine geometric structures. For each cue, we extract the relevant set of pixels from existing ground truth. We then apply our evaluation functions to quantify characteristics such as edge fattening and surface smoothness. We demonstrate that our approach supports practitioners in selecting the most suitable algorithm for their application. Using the new Middlebury dataset, we show that rankings based on our metrics reveal specific algorithm strengths and weaknesses which are not quantified by existing metrics. We finally show how stacked bar charts and radar charts visually support multidimensional performance evaluation. An interactive stereo benchmark based on the proposed metrics and visualizations is available at: http://hci.iwr.uni-heidelberg.de/stereometrics.
Katrin Honauer, Lena Maier-Hein, Daniel Kondermann
ICCV2
2015 Multi-sensor super-resolution for hybrid range imaging with application to 3-D endoscopy and open surgery
Thomas Köhler 0004, Sven Haase, Sebastian Bauer 0001, Jakob Wasza, Thomas Kilgus, Lena Maier-Hein, Christian Stock, Joachim Hornegger, Hubertus Feußner
Medical Image Anal.6
2014 Can Masses of Non-Experts Train Highly Accurate Image Classifiers? - A Crowdsourcing Approach to Instrument Segmentation in Laparoscopic Images
Lena Maier-Hein, Sven Mersmann, Daniel Kondermann, Sebastian Bodenstedt, Alexandro Sanchez, Christian Stock, Hannes Kenngott, Matthias Eisenmann, Stefanie Speidel
MICCAI (2)1
2014 Crowdsourcing for Reference Correspondence Generation in Endoscopic Images
Lena Maier-Hein, Sven Mersmann, Daniel Kondermann, Christian Stock, Hannes Kenngott, Alexandro Sanchez, Martin Wagner 0001, Anas Preukschas, Anna-Laura Wekerle, Stefanie Helfert, Sebastian Bodenstedt, Stefanie Speidel
MICCAI (2)1
2014 Pose-independent surface matching for intra-operative soft-tissue marker-less registration
Thiago R. dos Santos, Alexander Seitel, Thomas Kilgus, Stefan Suwelack, Anna-Laura Wekerle, Hannes Kenngott, Stefanie Speidel, Heinz-Peter Schlemmer, Hans-Peter Meinzer, Tobias Heimann, Lena Maier-Hein
Medical Image Anal.11
2014 Electromagnetic Tracking in Medicine - A Review of Technology, Validation, and Applications
abstract
Object tracking is a key enabling technology in the context of computer-assisted medical interventions. Allowing the continuous localization of medical instruments and patient anatomy, it is a prerequisite for providing instrument guidance to subsurface anatomical structures. The only widely used technique that enables real-time tracking of small objects without line-of-sight restrictions is electromagnetic (EM) tracking. While EM tracking has been the subject of many research efforts, clinical applications have been slow to emerge. The aim of this review paper is therefore to provide insight into the future potential and limitations of EM tracking for medical use. We describe the basic working principles of EM tracking systems, list the main sources of error, and summarize the published studies on tracking accuracy, precision and robustness along with the corresponding validation protocols proposed. State-of-the-art approaches to error compensation are also reviewed in depth. Finally, an overview of the clinical applications addressed with EM tracking is given. Throughout the paper, we report not only on scientific progress, but also provide a review on commercial systems. Given the continuous debate on the applicability of EM tracking in medicine, this paper provides a timely overview of the state-of-the-art in the field.
Alfred M. Franz, Tamás Haidegger, Wolfgang Birkfellner, Kevin Cleary, Terry M. Peters, Lena Maier-Hein
IEEE Trans. Medical Imaging6
2014 Comparative Validation of Single-Shot Optical Techniques for Laparoscopic 3-D Surface Reconstruction
abstract
Intra-operative imaging techniques for obtaining the shape and morphology of soft-tissue surfaces in vivo are a key enabling technology for advanced surgical systems. Different optical techniques for 3-D surface reconstruction in laparoscopy have been proposed, however, so far no quantitative and comparative validation has been performed. Furthermore, robustness of the methods to clinically important factors like smoke or bleeding has not yet been assessed. To address these issues, we have formed a joint international initiative with the aim of validating different state-of-the-art passive and active reconstruction methods in a comparative manner. In this comprehensive in vitro study, we investigated reconstruction accuracy using different organs with various shape and texture and also tested reconstruction robustness with respect to a number of factors like the pose of the endoscope as well as the amount of blood or smoke present in the scene. The study suggests complementary advantages of the different techniques with respect to accuracy, robustness, point density, hardware complexity and computation time. While reconstruction accuracy under ideal conditions was generally high, robustness is a remaining issue to be addressed. Future work should include sensor fusion and in vivo validation studies in a specific clinical context. To trigger further research in surface reconstruction, stereoscopic data of the study will be made publically available at www.open-CAS.com upon publication of the paper.
Lena Maier-Hein, Anja Groch, Adrien Bartoli, Sebastian Bodenstedt, G. Boissonnat, Ping-Lin Chang, Neil Clancy, Daniel S. Elson, Sven Haase, Eric Heim, Joachim Hornegger, Pierre Jannin, Hannes Kenngott, Thomas Kilgus, Beat P. Müller-Stich, D. Oladokun, Sebastian Röhl, Thiago R. dos Santos, Heinz-Peter Schlemmer, Alexander Seitel, Stefanie Speidel, Martin Wagner 0001, Danail Stoyanov
IEEE Trans. Medical Imaging1
2013 3-D Operation Situs Reconstruction with Time-of-Flight Satellite Cameras Using Photogeometric Data Fusion
Sven Haase, Sebastian Bauer 0001, Jakob Wasza, Thomas Kilgus, Lena Maier-Hein, Armin Schneider, Michael Kranzfelder, Hubertus Feußner, Joachim Hornegger
MICCAI (1)5
2013 ToF Meets RGB: Novel Multi-Sensor Super-Resolution for Hybrid 3-D Endoscopy
Thomas Köhler 0004, Sven Haase, Sebastian Bauer 0001, Jakob Wasza, Thomas Kilgus, Lena Maier-Hein, Hubertus Feußner, Joachim Hornegger
MICCAI (1)6
2013 Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery
Lena Maier-Hein, Peter Mountney, Adrien Bartoli, Haytham Elhawary, Daniel S. Elson, Anja Groch, Andreas Kolb 0001, Marcos A. Rodrigues 0001, Jonathan M. Sorger, Stefanie Speidel, Danail Stoyanov
Medical Image Anal.1
2012 Convergent Iterative Closest-Point Algorithm to Accomodate Anisotropic and Inhomogenous Localization Error
abstract
Since its introduction in the early 1990s, the Iterative Closest Point (ICP) algorithm has become one of the most well-known methods for geometric alignment of 3D models. Given two roughly aligned shapes represented by two point sets, the algorithm iteratively establishes point correspondences given the current alignment of the data and computes a rigid transformation accordingly. From a statistical point of view, however, it implicitly assumes that the points are observed with isotropic Gaussian noise. In this paper, we show that this assumption may lead to errors and generalize the ICP such that it can account for anisotropic and inhomogenous localization errors. We 1) provide a formal description of the algorithm, 2) extend it to registration of partially overlapping surfaces, 3) prove its convergence, 4) derive the required covariance matrices for a set of selected applications, and 5) present means for optimizing the runtime. An evaluation on publicly available surface meshes as well as on a set of meshes extracted from medical imaging data shows a dramatic increase in accuracy compared to the original ICP, especially in the case of partial surface registration. As point-based surface registration is a central component in various applications, the potential impact of the proposed method is high.
Lena Maier-Hein, Alfred M. Franz, Thiago R. dos Santos, Mirko Schmidt, Markus Fangerau, Hans-Peter Meinzer, J. Michael Fitzpatrick
IEEE Trans. Pattern Anal. Mach. Intell.1
2011 Robust multi-modal surface matching for intra-operative registration
abstract
Range imaging modalities, such as time-of-flight cameras (ToF), are becoming popular for the acquisition of intra-operative data, which can be used for registering the patient's anatomy with pre-operative data (e.g. Computed Tomography or Magnetic Resonance Imaging). As pre- and intra-operative data are acquired with different modalities, and are subject to different sources of error (systematic errors and noise), matching them is a challenging problem. We present a method for the registration of multi-modal surfaces, which is robust to high noise levels and is applicable to incomplete surfaces. An evaluation with simulated and real data demonstrates that the presented method is very accurate and is fast enough for intra-operative purposes.
Thiago R. dos Santos, Alfred M. Franz, Hans-Peter Meinzer, Lena Maier-Hein
CBMS4
2010 Accounting for Anisotropic Noise in Fine Registration of Time-of-Flight Range Data with High-Resolution Surface Data
Lena Maier-Hein, Mirko Schmidt, Alfred M. Franz, Thiago R. dos Santos, Alexander Seitel, Bernd Jähne, J. Michael Fitzpatrick, Hans-Peter Meinzer
MICCAI (1)1
2010 Correspondences Search for Surface-Based Intra-Operative Registration
Thiago R. dos Santos, Alexander Seitel, Hans-Peter Meinzer, Lena Maier-Hein
MICCAI (2)4
2007 Precision Targeting of Liver Lesions with a Needle-Based Soft Tissue Navigation System
Lena Maier-Hein, Frank Pianka, Alexander Seitel, Sascha A. Müller, Aysun Tekbas, Mathias Seitel, Ivo Wolf, Bruno M. Schmied, Hans-Peter Meinzer
MICCAI (2)1
2006 Articulatory Feature Classification using Surface Electromyography
abstract
In this paper, we present an approach for articulatory feature classification based on surface electromyographic signals generated by the facial muscles. With parallel recorded audible speech and electromyographic signals, experiments are conducted to show the anticipatory behavior of electromyographic signals with respect to speech signals. On average, we found that the signals to be time delayed by 0.02 to 0.12 second. Furthermore, it is shown that different articulators have different anticipatory behavior. With offset-aligned signals, we improved the average F-score of the articulatory feature classifiers in our baseline system from 0.467 to 0.502.
Szu-Chen Stan Jou, Lena Maier-Hein, Tanja Schultz, Alex Waibel
ICASSP (1)2