Demo Data from EDBT 2026 / reviewers in the wild / expert
Addison Liu
dblp:353/5930
· DBLP profile ↗
2ranked-venue papers
1as first author
2since 2021 · last 2024
—ORCID · none
Domains — the database's venue-derived domains; a paper can count in several
Artificial intelligence and machine learning · 2 · 1 first-author · 2 since 2021Systems, architecture and hardware · 2 · 1 first-author · 2 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Human-computer interaction and pervasive computing
1 paper |
Wearable and physiological sensing · 100% | |
| Artificial intelligence
1 paper |
Robot manipulation · 100% |
Topics — the 3 heaviest of 5, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Wearable and physiological sensing
physiological monitoring |
0.7 | 1 | 2023 | Design and characterization of a low mechanical loss, high-resolution wearable strain gauge · ICRA 2023 |
Robotics › Robot manipulation › actuator design
tendon-driven actuation |
0.2 | 1 | 2024 | A Flat Tendon-Driven Continuum Microrobot for Brain Interventions · ICRA 2024 |
Wearable and physiological sensing › flexible electronics
soft sensor fabrication |
0.2 | 1 | 2023 | Design and characterization of a low mechanical loss, high-resolution wearable strain gauge · ICRA 2023 |
Methods — techniques the papers use, named apart from their topics
microfabrication · 0.8strain-mediated contact sensing · 0.7silicone elastomer fabrication · 0.7
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2024 | A Flat Tendon-Driven Continuum Microrobot for Brain InterventionsabstractNavigating biomedical instruments inside the brain remains challenging and high-risk. The delicate nature of the tissues involved requires the development of cutting-edge robotic technologies to enhance precision and safety. In response to these demands, this paper presents a novel ribbon-shaped, tendon-driven continuum microrobot designed explicitly to navigate through brain tissues. The microrobot has a cross-sectional area of 1 mm2, and its design is readily compatible with conventional microfabrication techniques for further miniaturization. The flat geometry aims to provide superior maneuverability and opens up new challenges for modeling and control. We detail the design methodology and fabrication, followed by in vitro characterization and testing within brain tissue phantoms. Lorenzo Noseda, Addison Liu, Lucio Pancaldi, Mahmut Selman Sakar |
ICRA | 2 |
| 2023 | Design and characterization of a low mechanical loss, high-resolution wearable strain gaugeabstractSoft, wearable systems hold promise for a wide variety of new or enhanced applications in the realm of human-computer interaction, physiological monitoring, wear-able robotics, and a host of other human-centric devices. Soft sensor systems have been developed concurrently in order to allow these wearable systems to respond intelligently with their surroundings. A recently reported sensing mechanism based on the strain-mediated contact in anisotropically resistive structures (SCARS) is an attractive solution due to its high sensing resolution, low-profile nature, and high mechanical resilience. Furthermore, the resistance-based output provides a simple electronic readout, facilitating its use in a wide variety of applications. However, previous iterations of the sensing mech-anism have exhibited stress relaxation and hysteretic behaviors that limit the scope of its use. Here, we report an iteration of the SCARS mechanism that uses silicone-based materials with low mechanical loss in order to improve the sensor signal stability and bandwidth. A new fabrication approach is developed which permits the incorporation of a liquid elastomer adhesive layer while also preserving the SCARS sensing functionality. The silicone-based SCARS sensors exhibited fast stress relaxation response (< 1 s) and reduced cyclic drift properties by more than half that of previously reported designs. A physiological monitoring demonstration is presented, validating that the new sensor design is mechanically resilient to such applications and has potential for use in real-world wearable use cases. Addison Liu, Oluwaseun A. Araromi, Conor J. Walsh, Robert J. Wood |
ICRA | 1 |