Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Addison Liu

dblp:353/5930 · DBLP profile ↗
← Back
2ranked-venue papers
1as first author
2since 2021 · last 2024
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 2 · 1 first-author · 2 since 2021Systems, architecture and hardware · 2 · 1 first-author · 2 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Human-computer interaction and pervasive computing
1 paper
Wearable and physiological sensing · 100%
Artificial intelligence
1 paper
Robot manipulation · 100%

Topics — the 3 heaviest of 5, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Wearable and physiological sensing
physiological monitoring
0.712023
Design and characterization of a low mechanical loss, high-resolution wearable strain gauge · ICRA 2023
Robotics › Robot manipulation › actuator design
tendon-driven actuation
0.212024
A Flat Tendon-Driven Continuum Microrobot for Brain Interventions · ICRA 2024
Wearable and physiological sensing › flexible electronics
soft sensor fabrication
0.212023
Design and characterization of a low mechanical loss, high-resolution wearable strain gauge · ICRA 2023

Methods — techniques the papers use, named apart from their topics

microfabrication · 0.8strain-mediated contact sensing · 0.7silicone elastomer fabrication · 0.7
YearPublicationVenuePosition
2024 A Flat Tendon-Driven Continuum Microrobot for Brain Interventions
abstract
Navigating biomedical instruments inside the brain remains challenging and high-risk. The delicate nature of the tissues involved requires the development of cutting-edge robotic technologies to enhance precision and safety. In response to these demands, this paper presents a novel ribbon-shaped, tendon-driven continuum microrobot designed explicitly to navigate through brain tissues. The microrobot has a cross-sectional area of 1 mm2, and its design is readily compatible with conventional microfabrication techniques for further miniaturization. The flat geometry aims to provide superior maneuverability and opens up new challenges for modeling and control. We detail the design methodology and fabrication, followed by in vitro characterization and testing within brain tissue phantoms.
Lorenzo Noseda, Addison Liu, Lucio Pancaldi, Mahmut Selman Sakar
ICRA2
2023 Design and characterization of a low mechanical loss, high-resolution wearable strain gauge
abstract
Soft, wearable systems hold promise for a wide variety of new or enhanced applications in the realm of human-computer interaction, physiological monitoring, wear-able robotics, and a host of other human-centric devices. Soft sensor systems have been developed concurrently in order to allow these wearable systems to respond intelligently with their surroundings. A recently reported sensing mechanism based on the strain-mediated contact in anisotropically resistive structures (SCARS) is an attractive solution due to its high sensing resolution, low-profile nature, and high mechanical resilience. Furthermore, the resistance-based output provides a simple electronic readout, facilitating its use in a wide variety of applications. However, previous iterations of the sensing mech-anism have exhibited stress relaxation and hysteretic behaviors that limit the scope of its use. Here, we report an iteration of the SCARS mechanism that uses silicone-based materials with low mechanical loss in order to improve the sensor signal stability and bandwidth. A new fabrication approach is developed which permits the incorporation of a liquid elastomer adhesive layer while also preserving the SCARS sensing functionality. The silicone-based SCARS sensors exhibited fast stress relaxation response (< 1 s) and reduced cyclic drift properties by more than half that of previously reported designs. A physiological monitoring demonstration is presented, validating that the new sensor design is mechanically resilient to such applications and has potential for use in real-world wearable use cases.
Addison Liu, Oluwaseun A. Araromi, Conor J. Walsh, Robert J. Wood
ICRA1