Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Venkata Lavanya Sarvasiddi

dblp:355/5267 · DBLP profile ↗
← Back
1ranked-venue papers
0as first author
1since 2021 · last 2023
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Systems, architecture and hardware · 1 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer architecture, parallel and distributed computing, and storage systems
1 paper
Electronic design automation · 87% Embedded and real-time systems · 13%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Electronic design automation
microfluidic biochip design
0.712023
Preparing Fluid Samples Under Retention Time Constraints Using Flow-Based Microfluidic Biochips · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2023
Electronic design automation › microfluidic biochip design
sample preparation
0.712023
Preparing Fluid Samples Under Retention Time Constraints Using Flow-Based Microfluidic Biochips · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2023
Embedded and real-time systems
real-time scheduling
0.212023
Preparing Fluid Samples Under Retention Time Constraints Using Flow-Based Microfluidic Biochips · IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 2023

Methods — techniques the papers use, named apart from their topics

satisfiability · 0.7list scheduling · 0.7
YearPublicationVenuePosition
2023 Preparing Fluid Samples Under Retention Time Constraints Using Flow-Based Microfluidic Biochips
abstract
Sample preparation is an essential step in almost all bioprotocols, which can be efficiently achieved via a sequence of mixing steps called mixing graph. In the literature, several techniques have been reported to determine a mixing graph with the minimal number of mixing steps, the minimal usage of reagent fluids, the minimal wastage, or sometimes a combination of them. The retention time of a flow-based microfluidic biochip (FMB) is defined as the maximum duration for which a fluid can be stored within a microchannel without any fluid leakage. However, the retention time has not yet been considered as a scheduling constraint during the automation of the sample preparation using an FMB in order to obtain the scheduled mixing graphs. In this article, we propose a retention time-aware scheduling method called time-aware list scheduling (TALS), which can be used with the state-of-the-art methods, and a new satisfiability-based mixing algorithm called time-aware sample preparation (TASP) to obtain the scheduled mixing graph for a target ratio satisfying the retention time constraint and the number of available on-chip mixers in an FMB. Simulation results suggest that on an average TALS always outperforms a baseline scheduling method while scheduling any mixing graph, whereas TASP can determine the optimal and scheduled mixing graphs compared to the existing mixing methods combined with TALS.
Debraj Kundu, Venkata Lavanya Sarvasiddi, Sukanta Bhattacharjee, Shigeru Yamashita, Sudip Roy 0001
IEEE Trans. Comput. Aided Des. Integr. Circuits Syst.2