Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Annika Guez

dblp:360/8077 · also Annika S. Guez · DBLP profile ↗
← Back
2ranked-venue papers
0as first author
2since 2021 · last 2024
0000-0001-8702-7334ORCID · reported

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1 · 1 since 2021Systems, architecture and hardware · 1 · 1 since 2021Human-computer interaction and ubiquitous computing · 1 · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Motion planning and robot control · 100%
Human-computer interaction and pervasive computing
1 paper
Health and well-being technologies · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Robotics › Motion planning and robot control › robot control
exoskeleton control
0.812024
Transparency Control of a 1-DoF Knee Exoskeleton via Human-in-the-Loop Velocity Optimisation · ICRA 2024
Health and well-being technologies › rehabilitation technology
rehabilitation robotics
0.212024
Transparency Control of a 1-DoF Knee Exoskeleton via Human-in-the-Loop Velocity Optimisation · ICRA 2024

Methods — techniques the papers use, named apart from their topics

series elastic actuator · 1.5human-in-the-loop optimization · 1.5adaptive frequency oscillator · 1.5
YearPublicationVenuePosition
2024 Transparency Control of a 1-DoF Knee Exoskeleton via Human-in-the-Loop Velocity Optimisation
abstract
Rehabilitative robotics, particularly lower-limb exoskeletons (LLEs), have gained increasing importance in aiding patients regain ambulatory functions. One of the challenges in making these systems effective is the implementation of an assist-as-needed (AAN) control strategy that intervenes only when the patient deviates from the correct movement pattern. Equally crucial is the need for the LLE to exhibit "transparency" — minimising its interaction forces with the wearer to feel as natural as possible. This paper introduces a novel approach to transparency control based on a human-in-the-loop velocity optimisation framework. The proposed method employs torque data captured from past steps through a Series Elastic Actuator (SEA) to approximate the wearer’s intended future movements and computes a corresponding transparent velocity trajectory. The velocity commands are complemented by an Adaptive Frequency Oscillator (AFO) based position controller that leverages the periodic nature of human gait and is modified with a force sensor for increased reactiveness to human gait variations. This approach is experimentally evaluated against a standard zero-torque controller with a stationary single-degree-of-freedom knee exoskeleton test platform in a proof-of-concept study. Preliminary results indicate that combining adaptive oscillators with interaction force sensing can improve transparency compared to the conventional zero-torque controller, using force readings for position control and torque measurements for velocity optimisation and control.
Lukas Cha, Annika Guez, Sion Kim, Zhenhua Yu 0004, Bo Xiao 0002, Ravi Vaidyanathan
ICRA2
2024 Leveraging High-Density EMG to Investigate Bipolar Electrode Placement for Gait Prediction Models
abstract
To control wearable robotic systems, it is critical to obtain a prediction of the user's motion intent with high accuracy. Surface electromyography (sEMG) recordings have often been used as inputs for these devices, however bipolar sEMG electrodes are highly sensitive to their location. Positional shifts of electrodes after training gait prediction models can therefore result in severe performance degradation. This study uses high-density sEMG (HD-sEMG) electrodes to simulate various bipolar electrode signals from four leg muscles during steady-state walking. The bipolar signals were ranked based on the consistency of the corresponding sEMG envelope's activity and timing across gait cycles. The locations were then compared by evaluating the performance of an offline temporal convolutional network (TCN) that mapped sEMG signals to knee angles. The results showed that electrode locations with consistent sEMG envelopes resulted in greater prediction accuracy compared to hand-aligned placements (p$< $0.01). However, performance gains through this process were limited, and did not resolve the position shift issue. Instead of training a model for a single location, we showed that randomly sampling bipolar combinations across the HD-sEMG grid during training mitigated this effect. Models trained with this method generalized over all positions, and achieved 70% less prediction error than location specific models over the entire area of the grid. Therefore, the use of HD-sEMG grids to build training datasets could enable the development of models robust to spatial variations, and reduce the impact of muscle-specific electrode placement on accuracy.
Balint Hodossy, Annika Guez, Shibo Jing, Weiguang Huo, Ravi Vaidyanathan, Dario Farina
IEEE Trans. Hum. Mach. Syst.2