Demo Data from EDBT 2026 / reviewers in the wild / expert
Xiangyu Gong
dblp:364/6921
· DBLP profile ↗
2ranked-venue papers
0as first author
2since 2021 · last 2024
0000-0003-4033-9570ORCID · corroborated
Domains — the database's venue-derived domains; a paper can count in several
Computer networks · 2 · 2 since 2021
Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.
| Computer networks
2 papers |
Datacenter networks · 62% Transport protocols and congestion control · 20% Internet architecture and protocols · 17% |
Topics — the 5 heaviest of 5, each with the papers that count most for it
| Topic | Weight | Papers | Last | Evidence papers |
|---|---|---|---|---|
Datacenter networks › lossless ethernet
priority flow control |
1.4 | 2 | 2024 | Minimizing Buffer Utilization for Lossless Inter-DC Links · IEEE/ACM Trans. Netw. 2024 Bifrost: Extending RoCE for Long Distance Inter-DC Links · ICNP 2023 |
Transport protocols and congestion control
flow control |
0.9 | 2 | 2024 | Bifrost: Extending RoCE for Long Distance Inter-DC Links · ICNP 2023 Minimizing Buffer Utilization for Lossless Inter-DC Links · IEEE/ACM Trans. Netw. 2024 |
Internet architecture and protocols
buffer management |
0.8 | 1 | 2024 | Minimizing Buffer Utilization for Lossless Inter-DC Links · IEEE/ACM Trans. Netw. 2024 |
Datacenter networks › datacenter interconnect
inter-datacenter transfer |
0.7 | 1 | 2023 | Bifrost: Extending RoCE for Long Distance Inter-DC Links · ICNP 2023 |
Datacenter networks › RDMA
RDMA over Converged Ethernet |
0.7 | 1 | 2023 | Bifrost: Extending RoCE for Long Distance Inter-DC Links · ICNP 2023 |
Methods — techniques the papers use, named apart from their topics
virtual incoming packet · 0.8downstream-driven flow control · 0.8prototype evaluation · 0.7
| Year | Publication | Venue | Position |
|---|---|---|---|
| 2024 | Minimizing Buffer Utilization for Lossless Inter-DC LinksabstractRDMA over Converged Ethernet (RoCEv2) has been widely deployed to data centers (DCs) for its better compatibility with Ethernet/IP than Infiniband (IB). As cross-DC applications emerge, they also demand high throughput, low latency, and lossless network for cross-DC data transmission. However, RoCEv2’s underlying lossless mechanism Priority-based Flow Control (PFC) cannot fit into the long-haul transmission scenario and degrades the performance of RoCEv2. PFC is myopic and only considers queue length to pause upstream senders, which leads to large queueing delay. This paper proposes Bifrost, a downstream-driven lossless flow control that supports long distance cross-DC data transmission. Bifrost uses virtual incoming packets, which indicates the upper bound of in-flight packets, together with buffered packets to control the flow rate. It minimizes the buffer space requirement to one-hop bandwidth delay product (BDP) and achieves low one-way latency. Moreover, we extend Bifrost and propose BifrostX, to accommodate the multi-priority queue of the current switch implementation. BifrostX enables flow control for each queue separately while maintaining low buffer reservation, no throughput loss, and no packet loss. Real-world experiments are conducted with prototype switches and 80 kilometers cables. Evaluations demonstrate that compared to PFC, Bifrost reduces average/tail flow completion time (FCT) of inter-DC flows by up to 22.5%/42.0%, respectively. Bifrost is compatible with existing infrastructure and can support distance of thousands of kilometers. Chengyuan Huang, Feiyang Xue, Xiaoliang Wang 0001, Tao Wu 0011, Zifa Han, Xiangyu Gong, Chen Tian 0001, Wan-Chun Dou, Guihai Chen |
IEEE/ACM Trans. Netw. | 10 |
| 2023 | Bifrost: Extending RoCE for Long Distance Inter-DC LinksabstractRDMA over Converged Ethernet (RoCEv2) has been widely deployed to data centers (DCs) for its better compatibility with Ethernet/IP than Infiniband (IB). As cross-DC applications emerge, they also demand high throughput, low latency, and lossless network for cross-DC data transmission. However, RoCEv2's underlying lossless mechanism Priority-based Flow Control (PFC) cannot fit into the long-haul transmission scenario and degrades the performance of RoCEv2. PFC is myopic and only considers queue length to pause upstream senders, which leads to large queueing delay. This paper proposes Bifrost, a downstream-driven lossless flow control that supports long distance cross-DC data transmission. Bifrost uses virtual incoming packets, which indicates the upper bound of in-flight packets, together with buffered packets to control the flow rate. It minimizes the buffer space requirement to one-hop bandwidth delay product (BDP) and achieves low one-way latency. Real-world experiments are conducted with prototype switches and 80 kilometers cables. Evaluations demonstrate that compared to PFC, Bifrost reduces average/tail flow completion time (FCT) of inter-DC flows by up to 22.5%/42.0%, respectively. Bifrost is compatible with existing infrastructure and can support distance of thousands of kilometers. Feiyang Xue, Chen Tian 0001, Xiaoliang Wang 0001, Tao Wu 0011, Zifa Han, Xiangyu Gong, Wan-Chun Dou, Guihai Chen |
ICNP | 10 |