Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Richard Tascherau

dblp:37/5892 · DBLP profile ↗
← Back
2ranked-venue papers
0as first author
0since 2021 · last 2003
—ORCID · none

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 2Systems, architecture and hardware · 2

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 2 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
medical simulation
0.012003
Needle insertion and radioactive seed implantation in human tissues: simulation and sensitivity analysis · ICRA 2003
Medical and health informatics › medical simulation › surgical simulation
needle insertion simulation
0.012003
Needle insertion and radioactive seed implantation in human tissues: simulation and sensitivity analysis · ICRA 2003

Methods — techniques the papers use, named apart from their topics

sensitivity analysis · 0.0finite element method · 0.0
YearPublicationVenuePosition
2003 Needle insertion and radioactive seed implantation in human tissues: simulation and sensitivity analysis
abstract
To facilitate training and planning for medical procedures such as prostate brachytherapy, we are developing an interactive simulation of needle insertion and radioactive seed implantation in soft tissues. We describe a new 2D dynamic FEM model based on a reduced set of scalar parameters such as needle friction, sharpness, and velocity, where the mesh is updated to maintain element boundaries along the needle shaft and the effects of needle tip and frictional forces are simulated. The computational complexity of our model grows linearly with the number of elements in the mesh and achieves 24 frames per second for 1250 triangular elements on a 750 MHz PC. We use the simulator to characterize the sensitivity of seed placement error to physician-controlled and biological parameters. Results indicate that seed placement error is highly sensitive to physician-controlled parameters such as needle position, sharpness, and friction, and less sensitive to patient-specific parameters such as tissue stiffness and compressibility.
Ron Alterovitz, Kenneth Y. Goldberg, Jean Pouliot, Richard Tascherau, I-Chow Hsu
ICRA4
2003 Sensorless planning for medical needle insertion procedures
abstract
Medical procedures such as seed implantation, biopsies, and treatment injections require inserting a needle tip to a specific target location inside the human body. This is difficult because (1) needle insertion causes soft tissues to displace and deform, and (2) it is often difficult or impossible to obtain precise imaging data during insertion. We are developing a sensorless planning system for needle insertion that incorporates numerical optimization with a soft tissue simulation based on a dynamic FEM formulation that models the effects of needle tip and frictional forces using a 2D mesh. In this paper we describe a sensorless planning algorithm for radioactive seed implantation that computes needle insertion offsets that compensate for tissue deformations. We apply the method to seed implantation during permanent seed prostate brachytherapy to minimize seed placement error in simulation without relying on real-time imaging.
Ron Alterovitz, Kenneth Y. Goldberg, Jean Pouliot, Richard Tascherau, I-Chow Hsu
IROS4