Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Naner Li

dblp:383/4571 · DBLP profile ↗
← Back
1ranked-venue papers
1as first author
1since 2021 · last 2024
—ORCID · unresolved

Domains — the database's venue-derived domains; a paper can count in several

Artificial intelligence and machine learning · 1 · 1 first-author · 1 since 2021Systems, architecture and hardware · 1 · 1 first-author · 1 since 2021

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Artificial intelligence
1 paper
Robot manipulation · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 1 heaviest of 2, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics › image-guided intervention
endovascular intervention
0.212024
Vascular Centerline-Guided Autonomous Navigation Methods for Robot-Lead Endovascular Interventions · ICRA 2024

Methods — techniques the papers use, named apart from their topics

electromagnetic tracking · 1.5dynamic time warping · 1.5centerline-guided navigation · 1.5
YearPublicationVenuePosition
2024 Vascular Centerline-Guided Autonomous Navigation Methods for Robot-Lead Endovascular Interventions
abstract
In minimally invasive endovascular interventional surgery, guidewire navigation is an indispensable process. However, even experienced physicians often encounter difficulties in manually manipulating the guidewire for branch selection, while also facing the risk of radiation exposure. In this study, we investigated robotic autonomous guidewire navigation methods. An electromagnetic system was used to track the real-time position and orientation of the guidewire tip, and a state space representing the guidewire within the vascular environment was constructed to guide the robot in precise guidewire manipulation. Experimental results demonstrated that the proposed trial-and-error and centerline-guided methods successfully completed navigation tasks in a static environment, outperforming human navigation performance in terms of trajectory smoothness, trajectory length, and incorrect branch entry counts. For dynamic environment navigation, dynamic time warping (DTW), a technique for measuring the similarity between two temporal sequences, was integrated into the centerline-guided method. The proposed approaches eliminate the need for visual feedback and thereby minimizing the risk of radiation exposure for both patients and medical staff present in the operating room during the procedure.
Naner Li, Yiwei Wang 0002, Haoyuan Cheng, Huan Zhao 0001, Han Ding 0001
ICRA1