Demonstration venue · read-only. Every page can be browsed; the buttons that would change it are switched off. Create an account to run TaxoReview on your own data. A simulation from public publication records: the people listed were not invited and did not agree to review.
? Tutorial for this page

Jian Wang 0009

dblp:39/449-9 · DBLP profile ↗
← Back
11ranked-venue papers
4as first author
2since 2021 · last 2023
0000-0002-8454-7796ORCID · conflict

Domains — the database's venue-derived domains; a paper can count in several

Graphics, computer vision, multimedia, augmented reality and games · 7 · 3 first-author · 2 since 2021Applied, interdisciplinary, general and emerging computing · 6 · 1 first-author · 1 since 2021Artificial intelligence and machine learning · 1Human-computer interaction and ubiquitous computing · 1 · 1 first-author

Expertise — from the expertise taxonomy: the topics of the expert's papers under the CCF categories. A weight counts papers with recency: 1 for a paper about the topic, 0.3 when the topic is its context, halved every five years.

Computer graphics and multimedia
1 paper
Virtual and augmented reality · 100%
Interdisciplinary, comprehensive, and emerging computing
1 paper
Medical and health informatics · 100%

Topics — the 3 heaviest of 3, each with the papers that count most for it

TopicWeightPapersLastEvidence papers
Medical and health informatics
image-guided intervention
0.112012
Augmented reality during angiography: Integration of a virtual mirror for improved 2D/3D visualization · ISMAR 2012
Virtual and augmented reality › augmented reality
medical augmented reality
0.112012
Augmented reality during angiography: Integration of a virtual mirror for improved 2D/3D visualization · ISMAR 2012
Virtual and augmented reality › immersive interaction
virtual mirror
0.112012
Augmented reality during angiography: Integration of a virtual mirror for improved 2D/3D visualization · ISMAR 2012

Methods — techniques the papers use, named apart from their topics

user study · 0.3color depth encoding · 0.3
YearPublicationVenuePosition
2023 Self-Supervised 2D/3D Registration for X-Ray to CT Image Fusion
abstract
Deep Learning-based 2D/3D registration enables fast, robust, and accurate X-ray to CT image fusion when large annotated paired datasets are available for training. However, the need for paired CT volume and X-ray images with ground truth registration limits the applicability in interventional scenarios. An alternative is to use simulated X-ray projections from CT volumes, thus removing the need for paired annotated datasets. Deep Neural Networks trained exclusively on simulated X-ray projections can perform significantly worse on real X-ray images due to the domain gap. We propose a self-supervised 2D/3D registration framework combining simulated training with unsupervised feature and pixel space domain adaptation to overcome the domain gap and eliminate the need for paired annotated datasets. Our framework achieves a registration accuracy of 1.83 ± 1.16 mm with a high success ratio of 90.1% on real X-ray images showing a 23.9% increase in success ratio compared to reference annotation-free algorithms.
Srikrishna Jaganathan, Maximilian Kukla, Jian Wang 0009, Karthik Shetty, Andreas K. Maier
WACV3
2021 Deep Iterative 2D/3D Registration
Srikrishna Jaganathan, Jian Wang 0009, Anja Borsdorf, Karthik Shetty, Andreas K. Maier
MICCAI (4)2
2020 Learning an Attention Model for Robust 2-D/3-D Registration Using Point-To-Plane Correspondences
abstract
Minimally invasive procedures rely on image guidance for navigation at the operation site to avoid large surgical incisions. X-ray images are often used for guidance, but important structures may be not well visible. These structures can be overlaid from pre-operative 3-D images and accurate alignment can be established using 2-D/3-D registration. Registration based on the point-to-plane correspondence model was recently proposed and shown to achieve state-of-the-art performance. However, registration may still fail in challenging cases due to a large portion of outliers. In this paper, we describe a learning-based correspondence weighting scheme to improve the registration performance. By learning an attention model, inlier correspondences get higher attention in the motion estimation while the outlier correspondences are suppressed. Instead of using per-correspondence labels, our objective function allows to train the model directly by minimizing the registration error. We demonstrate a highly increased robustness, e.g. increasing the success rate from 84.9% to 97.0% for spine registration. In contrast to previously proposed learning-based methods, we also achieve a high accuracy of around 0.5mm mean re-projection distance. In addition, our method requires a relatively small amount of training data, is able to learn from simulated data, and generalizes to images with additional structures which are not present during training. Furthermore, a single model can be trained for both, different views and different anatomical structures.
Roman Schaffert, Jian Wang 0009, Peter Fischer 0001, Anja Borsdorf, Andreas K. Maier
IEEE Trans. Medical Imaging2
2020 Robust Multi-View 2-D/3-D Registration Using Point-To-Plane Correspondence Model
abstract
In minimally invasive procedures, the clinician relies on image guidance to observe and navigate the operation site. In order to show structures which are not visible in the live X-ray images, such as vessels or planning annotations, X-ray images can be augmented with pre-operatively acquired images. Accurate image alignment is needed and can be provided by 2-D/3-D registration. In this paper, a multi-view registration method based on the point-to-plane correspondence model is proposed. The correspondence model is extended to be independent of the used camera coordinates and different multi-view registration schemes are introduced and compared. Evaluation is performed for a wide range of clinically relevant registration scenarios. We show for different applications that registration using correspondences from both views simultaneously provides accurate and robust registration, while the performance of the other schemes varies considerably. Our method also outperforms the state-of-the-art method for cerebral angiography registration, achieving a capture range of 18 mm and an accuracy of 0.22±0.07 mm. Furthermore, investigations on the minimum angle between the views are performed in order to provide accurate and robust registration, while minimizing the obstruction to the clinical workflow. We show that small angles around 30° are sufficient to provide reliable registration results.
Roman Schaffert, Jian Wang 0009, Peter Fischer 0001, Andreas K. Maier, Anja Borsdorf
IEEE Trans. Medical Imaging2
2017 Pattern Visualization and Recognition Using Tensor Factorization for Early Differential Diagnosis of Parkinsonism
Rui Li 0053, Ping Wu 0003, Igor Yakushev, Jian Wang 0009, Sibylle Ilse Ziegler, Stefan Förster, Sung-Cheng Huang, Markus Schwaiger, Nassir Navab, Chuantao Zuo, Kuangyu Shi
MICCAI (3)4
2017 Dynamic 2-D/3-D Rigid Registration Framework Using Point-To-Plane Correspondence Model
abstract
In image-guided interventional procedures, live 2-D X-ray images can be augmented with preoperative 3-D computed tomography or MRI images to provide planning landmarks and enhanced spatial perception. An accurate alignment between the 3-D and 2-D images is a prerequisite for fusion applications. This paper presents a dynamic rigid 2-D/3-D registration framework, which measures the local 3-D-to-2-D misalignment and efficiently constrains the update of both planar and non-planar 3-D rigid transformations using a novel point-to-plane correspondence model. In the simulation evaluation, the proposed method achieved a mean 3-D accuracy of 0.07 mm for the head phantom and 0.05 mm for the thorax phantom using single-view X-ray images. In the evaluation on dynamic motion compensation, our method significantly increases the accuracy comparing with the baseline method. The proposed method is also evaluated on a publicly-available clinical angiogram data set with "gold-standard" registrations. The proposed method achieved a mean 3-D accuracy below 0.8 mm and a mean 2-D accuracy below 0.3 mm using single-view X-ray images. It outperformed the state-of-the-art methods in both accuracy and robustness in single-view registration. The proposed method is intuitive, generic, and suitable for both initial and dynamic registration scenarios.
Jian Wang 0009, Roman Schaffert, Anja Borsdorf, Benno Heigl, Xiaolin Huang, Joachim Hornegger, Andreas K. Maier
IEEE Trans. Medical Imaging1
2015 Epipolar Consistency in Fluoroscopy for Image-Based Tracking
abstract
Geometry and physics of absorption imaging impose certain constraints on X-ray projections. Recently, the Epipolar Consistency Conditions (ECC) have been introduced and applied to motion correction in flat-detector computed tomography (CT). They are based on redundant information in transmission images along epipolar lines. Unlike other consistency conditions for CT scans, they act directly on an arbitrary pair of X-ray images. This paper proposes an application of ECC to 3D patient tracking in interventional radiology. We evaluate the proposed method against 2D-3D registration with a previously acquired CT. Our experiments on synthetic data based on a patient CT and phantom data from an interventional C-arm demonstrate that our method is able to compensate online for rotations of up to ±10° and translations of ±25 mm between consecutive frames. We successfully track rotations of as much as 45° over 45 images. The outstanding property of the approach is that no 3D scan is required for tracking a 3D object in space. We show, that small rotations of about 3° in space and translations of about 50 mm can be tracked based on just two reference X-ray images. Since the proposed approach works directly on X-ray images, it exceeds regular 2D-3D registration with a CT in an order of magnitude in computational speed. We conclude that ECC are a simple and effective new tool for pre-aligment and online patient tracking for fluoroscopic sequences.
André Aichert, Jian Wang 0009, Roman Schaffert, Arnd Dörfler, Joachim Hornegger, Andreas K. Maier
BMVC2
2015 Epipolar Consistency in Transmission Imaging
abstract
This paper presents the derivation of the Epipolar Consistency Conditions (ECC) between two X-ray images from the Beer-Lambert law of X-ray attenuation and the Epipolar Geometry of two pinhole cameras, using Grangeat's theorem. We motivate the use of Oriented Projective Geometry to express redundant line integrals in projection images and define a consistency metric, which can be used, for instance, to estimate patient motion directly from a set of X-ray images. We describe in detail the mathematical tools to implement an algorithm to compute the Epipolar Consistency Metric and investigate its properties with detailed random studies on both artificial and real FD-CT data. A set of six reference projections of the CT scan of a fish were used to evaluate accuracy and precision of compensating for random disturbances of the ground truth projection matrix using an optimization of the consistency metric. In addition, we use three X-ray images of a pumpkin to prove applicability to real data. We conclude, that the metric might have potential in applications related to the estimation of projection geometry. By expression of redundancy between two arbitrary projection views, we in fact support any device or acquisition trajectory which uses a cone-beam geometry. We discuss certain geometric situations, where the ECC provide the ability to correct 3D motion, without the need for 3D reconstruction.
André Aichert, Martin Berger 0002, Jian Wang 0009, Nicole Maass, Arnd Dörfler, Joachim Hornegger, Andreas K. Maier
IEEE Trans. Medical Imaging3
2014 Gradient-Based Differential Approach for 3-D Motion Compensation in Interventional 2-D/3-D Image Fusion
abstract
In interventional radiology, preoperative 3-D volumes can be fused with intra-operative 2-D fluoroscopic images. Since the accuracy is crucial to the clinical usability of image fusion, patient motion resulting in misalignments has to be corrected during the procedure. In this paper, a novel gradient based differential approach is proposed to estimate the 3-D rigid motion from the 2-D tracking of contour points. The mathematical relationship between the 3-D differential motion and the 2-D motion is derived using the 3-D gradient, based on which a tracking-based motion compensation pipeline is introduced. Given the initial registration, the contour points are extracted and tracked along 2-D frames. The 3-D rigid motion is estimated using the iteratively re-weighted least square minimization to enhance the robustness. Our novel approach is evaluated on 10 datasets consisting of 1010 monoplane fluoroscopic images of a thorax phantom with 3-D rigid motion. Over all datasets, the maximum structure shift in the 2-D projection caused by the 3-D motion varies from 17.3 mm to 33.2 mm. Our approach reduces the 2-D structure shift to the range of 1.93 mm to 6.52 mm. For the most challenging longitudinal off-plane rotation, our approach achieves an average coverage of 79.9% regarding to the ground truth.
Jian Wang 0009, Anja Borsdorf, Benno Heigl, Thomas Köhler 0004, Joachim Hornegger
3DV1
2013 Sparse Depth Sampling for Interventional 2-D/3-D Overlay: Theoretical Error Analysis and Enhanced Motion Estimation
Jian Wang 0009, Christian Riess, Anja Borsdorf, Benno Heigl, Joachim Hornegger
CAIP (1)1
2012 Augmented reality during angiography: Integration of a virtual mirror for improved 2D/3D visualization
abstract
Visualizing 2D and 3D anatomical information simultaneously within an X-ray image is challenging. Multiple monitors are required in the operating room to enable visualization of anatomical data by the surgeon. Consequently, this results in an interruption during the operation for proper assessment of information. In this paper, we introduce an interactive visualization of the 3D data from new perspectives including visualizing a virtual mirror from the same viewpoint as the X-ray source. The main contribution is our development of a complete angiographic visualization system that displays simultaneous 2D X-ray and 3D anatomical information in a common monitor for the surgeon in the operating room. No previous works have conceived the integration of the virtual mirror into the projection geometry of a C-arm fluoroscope. In total, 24 participants were asked to assess the benefits of the angiographic virtual mirror with different colour-depth encodings. The results of our feasibility study show a clear improvement when deciphering the true positions of aneurysms in X-ray. Lastly, color depth encoding improves correspondence between the 3D vasculature displayed in the virtual mirror to their projection images in X-ray.
Jian Wang 0009, Pascal Fallavollita, Lejing Wang, Matthias Kreiser, Nassir Navab
ISMAR1